Detection of cerebral NAD+ by in vivo1H NMR spectroscopy
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Nicotinamide adenine dinucleotide (NAD+) plays a central role in cellular metabolism both as a coenzyme for electron‐transfer enzymes as well as a substrate for a wide range of metabolic pathways. In the current study NAD+ was detected on rat brain in vivo at 11.7T by 3D localized 1 H MRS of the NAD+ nicotinamide protons in the 8.7–9.5 ppm spectral region. Avoiding water perturbation was critical to the detection of NAD+ as strong, possibly indirect cross‐relaxation between NAD+ and water would lead to a several‐fold reduction of the NAD+ intensity in the presence of water suppression. Water perturbation was minimized through the use of localization by adiabatic spin‐echo refocusing (LASER) in combination with frequency‐selective excitation. The NAD+ concentration in the rat cerebral cortex was determined at 296 ± 28 μ m, which is in good agreement with recently published 31 P NMR‐based results as well as results from brain extracts in vitro (355 ± 34 μ m). The T1 relaxation time constants of the NAD+ nicotinamide protons as measured by inversion recovery were 280 ± 65 and 1136 ± 122 ms in the absence and presence of water inversion, respectively. This confirms the strong interaction between NAD+ nicotinamide and water protons as observed during water suppression. The T2 relaxation time constants of the NAD+ nicotinamide protons were determined at 60 ± 13 ms after confounding effects of scalar coupling evolution were taken into account. The simplicity of the MR sequence together with the robustness of NAD+ signal detection and quantification makes the presented method a convenient choice for studies on NAD+ metabolism and function. As the method does not critically rely on magnetic field homogeneity and spectral resolution it should find immediate applications in rodents and humans even at lower magnetic fields. Copyright © 2014 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Williamson, D., Lund, P., & Krebs, H. (1967) · Biochemical Journal · doi:10.1042/bj1030514 · Cited by 1,871 · cited 1×
“incompatible with (longitudinal) in vivo studies (10,11).”
Circadian Control of the NAD + Salvage Pathway by CLOCK-SIRT1
Nakahata, Y., Sahar, S., Astarita, G., Kaluzova, M., & Sassone-Corsi, P. (2009) · Science · doi:10.1126/science.1170803 · Cited by 1,198
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
The secret life of NAD+: an old metabolite controlling new metabolic signaling pathways
Houtkooper, R. H., Cantó, C., Wanders, R. J., & Auwerx, J. (2010) · Endocrine Reviews · doi:10.1210/er.2009-0026 · Cited by 899
The Role of PARP-1 and PARP-2 Enzymes in Metabolic Regulation and Disease
Bai, P., & Cantó, C. (2012) · Cell Metabolism · doi:10.1016/j.cmet.2012.06.016 · Cited by 312
Cited by
Henriques Pereira, D. P., Leethaus, J., Beyazay, T., do Nascimento Vieira, A., Kleinermanns, K., Tüysüz, H., Martin, W. F., & Preiner, M. (2022) · The FEBS Journal · doi:10.1111/febs.16329 · Cited by 42
Deuterium metabolic imaging reports on tert expression and early response to therapy in cancer
Batsios, G., Taglang, C., Tran, M., Stevers, N., Barger, C., Gillespie, A. M., Ronen, S. M., Costello, J. F., & Viswanath, P. (2022) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-21-4418 · Cited by 40
“Direct in vivo 1 H-MRS-based detection of NAD(H) (representing the sum of NAD+ and NADH since these cannot be spectrally resolved) is complicated by issues of water suppression and the need for highly specialized acquisition schemes (46).”
Conley, K. E., Ali, A. S., Flores, B., Jubrias, S. A., & Shankland, E. G. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00045 · Cited by 22
PARP inhibitor rucaparib induces changes in NAD levels in cells and liver tissues as assessed by MRS
Almeida, G. S., Bawn, C. M., Galler, M., Wilson, I., Thomas, H. D., Kyle, S., Curtin, N. J., Newell, D. R., & Maxwell, R. J. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3736 · Cited by 16
“Measurements of NAD from in vivo MR spectra have been shown to be feasible at higher magnetic fields in the brain by (31)P‐magnetic resonance spectroscopy ((31)P‐MRS)(19,20) and (1)H‐MRS.(21) Given the relatively low concentration and, consequently, signal intensity in the NAD region of the spectrum, it is expected th…”
Background
Metadata
- Authors
- de Graaf, R. A., & Behar, K. L.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2014-05-15
- Volume
- 27
- Issue
- 7
- Pages
- 802-809
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2098028110
- Cited by
- 57
- References
- 5
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.