The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Streaking artifact reduction for quantitative susceptibility mapping of sources with large dynamic range
Open accessAbstract
Quantitative susceptibility mapping (QSM) is a novel MRI technique for the measurement of tissue magnetic susceptibility in three dimensions. Although numerous algorithms have been developed to solve this ill‐posed inverse problem, the estimation of susceptibility maps with a wide range of values is still problematic. In cases such as large veins, contrast agent uptake and intracranial hemorrhages, extreme susceptibility values in focal areas cause severe streaking artifacts. To enable the reduction of these artifacts, whilst preserving subtle susceptibility contrast, a two‐level QSM reconstruction algorithm (streaking artifact reduction for QSM, STAR‐QSM) was developed in this study by tuning a regularization parameter to automatically reconstruct both large and small susceptibility values. Compared with current state‐of‐the‐art QSM methods, such as the improved sparse linear equation and least‐squares (iLSQR) algorithm, STAR‐QSM significantly reduced the streaking artifacts, whilst preserving the sharp boundaries for blood vessels of mouse brains in vivo and fine anatomical details of high‐resolution mouse brains ex vivo. Brain image data from patients with cerebral hematoma and multiple sclerosis further illustrated the superiority of this method in reducing streaking artifacts caused by large susceptibility sources, whilst maintaining sharp anatomical details. STAR‐QSM is implemented in STI Suite, a comprehensive shareware for susceptibility imaging and quantification. Copyright © 2015 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Sparse Reconstruction by Separable Approximation
Wright, S. J., Nowak, R. D., & Figueiredo, M. A. T. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2016892 · Cited by 1,854
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Quantitative susceptibility mapping of human brain reflects spatial variation in tissue composition
Li, W., Wu, B., & Liu, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.088 · Cited by 624
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
MRI estimates of brain iron concentration in normal aging using quantitative susceptibility mapping
Bilgic, B., Pfefferbaum, A., Rohlfing, T., Sullivan, E. V., & Adalsteinsson, E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.077 · Cited by 499
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Whole brain susceptibility mapping using compressed sensing
Wu, B., Li, W., Guidon, A., & Liu, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23000 · Cited by 417
Self-citationLayer-specific variation of iron content in cerebral cortex as a source of MRI contrast
Fukunaga, M., Li, T.-Q., van Gelderen, P., de Zwart, J. A., Shmueli, K., Yao, B., Lee, J., Maric, D., Aronova, M. A., Zhang, G., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911177107 · Cited by 408
Salomir, R., de Senneville, B. D., & Moonen, C. T. (2003) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.10083 · Cited by 389
Liu, T., Wisnieff, C., Lou, M., Chen, W., Spincemaille, P., & Wang, Y. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24272 · Cited by 360
A method for estimating and removing streaking artifacts in quantitative susceptibility mapping
Li, W., Wang, N., Yu, F., Han, H., Cao, W., Romero, R., Tantiwongkosi, B., Duong, T. Q., & Liu, C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.043 · Cited by 337
Self-citationde Rochefort, L., Brown, R., Prince, M. R., & Wang, Y. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21710 · Cited by 293
Sensitivity of MRI resonance frequency to the orientation of brain tissue microstructure
Lee, J., Shmueli, K., Fukunaga, M., van Gelderen, P., Merkle, H., Silva, A. C., & Duyn, J. H. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910222107 · Cited by 263
Chen, W., Zhu, W., Kovanlikaya, I., Kovanlikaya, A., Liu, T., Wang, S., Salustri, C., & Wang, Y. (2014) · Radiology · doi:10.1148/radiol.13122640 · Cited by 250
Susceptibility mapping in the human brain using threshold‐based k‐space division
Wharton, S., Schäfer, A., & Bowtell, R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22334 · Cited by 244
Schweser, F., Sommer, K., Deistung, A., & Reichenbach, J. R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.067 · Cited by 241
Magnetic susceptibility-weighted MR phase imaging of the human brain.
Rauscher, A., Sedlacik, J., Barth, M., Mentzel, H., & Reichenbach, J. R. (2005) · PubMed Central · Cited by 227
Fast quantitative susceptibility mapping using 3D EPI and total generalized variation
Langkammer, C., Bredies, K., Poser, B. A., Barth, M., Reishofer, G., Fan, A. P., Bilgic, B., Fazekas, F., Mainero, C., & Ropele, S. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.041 · Cited by 189
Wharton, S., & Bowtell, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.070 · Cited by 187
Background field removal using spherical mean value filtering and Tikhonov regularization
Sun, H., & Wilman, A. H. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24765 · Cited by 185
Toward online reconstruction of quantitative susceptibility maps: Superfast dipole inversion
Schweser, F., Deistung, A., Sommer, K., & Reichenbach, J. R. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24405 · Cited by 169
Wycliffe, N., Choe, J., Holshouser, B. A., Oyoyo, U. E., Haacke, E. M., & Kido, D. K. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20130 · Cited by 150
Tang, J., Liu, S., Neelavalli, J., Cheng, Y. N., Buch, S., & Haacke, E. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24384 · Cited by 133
Fast quantitative susceptibility mapping with L1‐regularization and automatic parameter selection
Bilgiç, B., Fan, A. P., Polimeni, J. R., Cauley, S., Bianciardi, M., Elfar Adalsteinsson, A., Wald, L. L., & Setsompop, K. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25029 · Cited by 130
Abduljalil, A., Schmalbrock, P., Novak, V., & Chakeres, D. W. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10362 · Cited by 128
Background field removal using spherical mean value filtering and Tikhonov regularization
Wilman (2017) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r32j68j2q · Cited by 97
Sensitivity encoding reconstruction with nonlocal total variation regularization
Liang, D., Wang, H., Chang, Y., & Ying, L. L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22736 · Cited by 96
Functional quantitative susceptibility mapping (fQSM)
Balla, D. Z., Sanchez-Panchuelo, R. M., Wharton, S., Hagberg, G. E., Scheffler, K., Francis, S., & Bowtell, R. W. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.011 · Cited by 92
Radiologic estimation of hematoma volume in intracerebral hemorrhage trial by CT scan.
Zimmerman, R. D., Maldjian, J. A., Brun, N. C., Horvath, B., & Skolnick, B. E. (2006) · PubMed Central · Cited by 90
Magnetic susceptibility quantification for arbitrarily shaped objects in inhomogeneous fields
Li, L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1276 · Cited by 76
Susceptibility‐based analysis of dynamic gadolinium bolus perfusion MRI
Bonekamp, D., Barker, P. B., Leigh, R. J., van Zijl, P. C. M., & Li, X. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25144 · Cited by 22
Microstructural origins of gadolinium‐enhanced susceptibility contrast and anisotropy
Dibb, R., Li, W., Cofer, G. P., & Liu, C. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25082 · Cited by 21
Self-citationWen, Y., Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25652 · Cited by 15
Cited by
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Wang, Y., Spincemaille, P., Liu, Z., Dimov, A., Deh, K., Li, J., Zhang, Y., Yao, Y., Gillen, K. M., Wilman, A. H., et al. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25693 · Cited by 273
Kim, E., Di Censo, D., Baraldo, M., Simmons, C., Rosa, I., Randall, K., Ballard, C., Dickie, B. R., Williams, S. C. R., Killick, R., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-91899-5 · Cited by 15
Metadata
- Authors
- Wei, H., Dibb, R., Zhou, Y., Sun, Y., Xu, J., Wang, N., & Liu, C.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2015-08-27
- Volume
- 28
- Issue
- 10
- Pages
- 1294-1303
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1841022102
- Cited by
- 277
- References
- 37
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).