Validation of a fast method for quantification of intra‐abdominal and subcutaneous adipose tissue for large‐scale human studies

Borga, Magnus, Thomas, E Louise, Romu, Thobias, Rosander, Johannes, Fitzpatrick, Julie, Dahlqvist Leinhard, Olof, Bell, Jimmy D. · 2015 · NMR in Biomedicine
Cited by 74

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Central obesity is the hallmark of a number of non‐inheritable disorders. The advent of imaging techniques such as MRI has allowed for a fast and accurate assessment of body fat content and distribution. However, image analysis continues to be one of the major obstacles to the use of MRI in large‐scale studies. In this study we assess the validity of the recently proposed fat–muscle quantitation system (AMRA TM Profiler) for the quantification of intra‐abdominal adipose tissue (IAAT) and abdominal subcutaneous adipose tissue (ASAT) from abdominal MR images. Abdominal MR images were acquired from 23 volunteers with a broad range of BMIs and analysed using sliceOmatic, the current gold‐standard, and the AMRA TM Profiler based on a non‐rigid image registration of a library of segmented atlases. The results show that there was a highly significant correlation between the fat volumes generated by the two analysis methods, (Pearson correlation r = 0.97, p < 0.001), with the AMRA TM Profiler analysis being significantly faster (~3 min) than the conventional sliceOmatic approach (~40 min). There was also excellent agreement between the methods for the quantification of IAAT (AMRA 4.73 ± 1.99 versus sliceOmatic 4.73 ± 1.75 l, p = 0.97). For the AMRA TM Profiler analysis, the intra‐observer coefficient of variation was 1.6% for IAAT and 1.1% for ASAT, the inter‐observer coefficient of variation was 1.4% for IAAT and 1.2% for ASAT, the intra‐observer correlation was 0.998 for IAAT and 0.999 for ASAT, and the inter‐observer correlation was 0.999 for both IAAT and ASAT. These results indicate that precise and accurate measures of body fat content and distribution can be obtained in a fast and reliable form by the AMRA TM Profiler, opening up the possibility of large‐scale human phenotypic studies. Copyright © 2015 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.3432

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Borga, M., Thomas, E. L., Romu, T., Rosander, J., Fitzpatrick, J., Dahlqvist Leinhard, O., & Bell, J. D.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2015-11-02
Volume
28
Issue
12
Pages
1747-1753
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W1912016580
Cited by
74
References
5
FWCI
4.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.