Fundamentals of diffusion MRI physics
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Diffusion MRI is commonly considered the “engine” for probing the cellular structure of living biological tissues. The difficulty of this task is threefold. First, in structurally heterogeneous media, diffusion is related to structure in quite a complicated way. The challenge of finding diffusion metrics for a given structure is equivalent to other problems in physics that have been known for over a century. Second, in most cases the MRI signal is related to diffusion in an indirect way dependent on the measurement technique used. Third, finding the cellular structure given the MRI signal is an ill‐posed inverse problem. This paper reviews well‐established knowledge that forms the basis for responding to the first two challenges. The inverse problem is briefly discussed and the reader is warned about a number of pitfalls on the way.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Diffusion in Brain Extracellular Space
Syková, E., & Nicholson, C. (2008) · Physiological Reviews · doi:10.1152/physrev.00027.2007 · Cited by 1,481
Extracellular space structure revealed by diffusion analysis
Nicholson, C., & Syková, E. (1998) · Trends in Neurosciences · doi:10.1016/s0166-2236(98)01261-2 · Cited by 914 · cited 1×
“Dapp = ∫ q(t1)q(t2)D(t)dt1dt2 ∫ |q(t′)|2dt′ = ∫ |q(ω)|2 D(ω) dω 2π ∫ |q(ω)|2 dω 2π (36)”
Assaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
Jespersen, S. N., Bjarkam, C. R., Nyengaard, J. R., Chakravarty, M. M., Hansen, B., Vosegaard, T., Østergaard, L., Yablonskiy, D., Nielsen, N. C., & Vestergaard-Poulsen, P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.053 · Cited by 290
Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
Does, M. D., Parsons, E. C., & Gore, J. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10385 · Cited by 246 · cited 1×
“Equation 52 can be re-written in the form [ −iω + R2 + D0q(2) − Σ(ω, q) ] G(ω, q) = 1 (55)”
Cited by
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Self-citationNovikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Self-citationDesign and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240
“Moreover, the estimated distribution does not mirror the actual distribution of diffusion coefficients in the tissue unless the measurement is performed in a very strong diffusion weighting regime (qlc ≫ 1, where q is the amount of spatial phase-warping introduced and lc is the diffusion distance) [9, 22].”
InfluentialHuang, S. Y., Witzel, T., Keil, B., Scholz, A., Davids, M., Dietz, P., Rummert, E., Ramb, R., Kirsch, J. E., Yendiki, A., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118530 · Cited by 181
“, 2016), the experience gained over the last decade has demonstrated that dedicated high-gradient performance scanners can also acquire a rich array of dMRI measurements that allow unparalleled in vivo assessment of neural tissue microscale structure (Alexander et al., 2017; Jelescu and Budde, 2017; Kiselev, 2017; Lam…”
On the scaling behavior of water diffusion in human brain white matter
Veraart, J., Fieremans, E., & Novikov, D. S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.075 · Cited by 141
“The sensitivity to tissue microstructure, however, is bound to be indirect, and cellular parameters can only be quantified by virtue of biophysical modeling, which links biomedical imaging with fundamental physics paradigms (Lerch et al., 2017; Kiselev, 2017; Novikov et al., 2018a, 2018b; Jespersen, 2018).”
Searching for the neurite density with diffusion MRI: challenges for biophysical modeling
Lampinen, B., Szczepankiewicz, F., Novén, M., van Westen, D., Hansson, O., Englund, E., Mårtensson, J., Westin, C., & Nilsson, M. (2019) · Human Brain Mapping · doi:10.1002/hbm.24542 · Cited by 123
“…constrained model featured the “ball” constraint, thus assuming isotropic diffusion outside of “stick-like” structures, which may be inaccurate in regions with high orientation coherence (Fieremans et al., 2011; Novikov, Veraart, et al., 2018; Reisert, Kellner, Dhital, Hennig, & Kiselev, 2017).”
InfluentialCoelho, S., Pozo, J. M., Jespersen, S. N., Jones, D. K., & Frangi, A. F. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27714 · Cited by 76
“= (1− f ) � D e Δe � H((2)) xx + H((2)) yy � + D e 2 � −DxxDyy”
InfluentialWhite matter biomarkers from diffusion MRI
Nørhøj Jespersen, S. (2018) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2018.03.001 · Cited by 34
Guerreri, M., Palombo, M., Caporale, A., Fasano, F., Macaluso, E., Bozzali, M., & Capuani, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.12.044 · Cited by 31
“…or “statistical models” such as DTI and diffusion kurtosis imaging (DKI) quantify parameters deriving from statistical mechanics without assumptions about the underlying tissue, but they lack specificity, and provide only an indirect characterization of the microstructure (Kiselev, 2017).”
Engineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Metadata
- Authors
- Kiselev, V. G.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2017-02-23
- Volume
- 30
- Issue
- 3
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2590243193
- Cited by
- 125
- References
- 12
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.