Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 620

The DOI matches its Crossref record; 283 of the 283 references it cites were found in a registry or an index.

Hypoxia: Importance in tumor biology, noninvasive measurement by imaging, and value of its measurement in the management of cancer therapy

Tatum, James L·2006·International Journal of Radiation Biology

Abstract

PURPOSE: The Cancer Imaging Program of the National Cancer Institute convened a workshop to assess the current status of hypoxia imaging, to assess what is known about the biology of hypoxia as it relates to cancer and cancer therapy, and to define clinical scenarios in which in vivo hypoxia imaging could prove valuable. RESULTS: Hypoxia, or low oxygenation, has emerged as an important factor in tumor biology and response to cancer treatment. It has been correlated with angiogenesis, tumor aggressiveness, local recurrence, and metastasis, and it appears to be a prognostic factor for several cancers, including those of the cervix, head and neck, prostate, pancreas, and brain. The relationship between tumor oxygenation and response to radiation therapy has been well established, but hypoxia also affects and is affected by some chemotherapeutic agents. Although hypoxia is an important aspect of tumor physiology and response to treatment, the lack of simple and efficient methods to measure and image oxygenation hampers further understanding and limits their prognostic usefulness. There is no gold standard for measuring hypoxia; Eppendorf measurement of pO(2) has been used, but this method is invasive. Recent studies have focused on molecular markers of hypoxia, such as hypoxia inducible factor 1 (HIF-1) and carbonic anhydrase isozyme IX (CA-IX), and on developing noninvasive imaging techniques. CONCLUSIONS: This workshop yielded recommendations on using hypoxia measurement to identify patients who would respond best to radiation therapy, which would improve treatment planning. This represents a narrow focus, as hypoxia measurement might also prove useful in drug development and in increasing our understanding of tumor biology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09553000601002324

Cites

283 of 283 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 283 references

Cited by

See all 620

Metadata

Authors
Tatum, J. L.
Venue
International Journal of Radiation Biology
Published
2006-01
Volume
82
Issue
10
Pages
699-757
ISSN
  • 0955-3002 (ISSN-L)
  • 1362-3095
OpenAlex
W2116263694
Cited by
620
References
283
FWCI
13.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hypoxia: Importance in tumor biology, noninvasive measurement by imaging, and value of its measurement in the management of cancer therapy. https://app.cochat.ai/papers/10.1080/09553000601002324
The paper
Tatum, J. L. (2006). Hypoxia: Importance in tumor biology, noninvasive measurement by imaging, and value of its measurement in the management of cancer therapy. International Journal of Radiation Biology. https://doi.org/10.1080/09553000601002324

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.