The DOI matches its Crossref record.
1H and 13C HR‐MAS spectroscopy of intact biopsy samples ex vivo and in vivo1H MRS study of human high grade gliomas
Abstract
High‐resolution magic angle spinning (HR‐MAS) one‐ and two‐dimensional 1 H and 13 C nuclear magnetic resonance (NMR) spectroscopy has been used to study intact glioblastoma (GBM) brain tumour tissue. The results were compared with in vitro chemical extract and in vivo spectra. The resolution of 1 H one‐dimensional, 1 H TOCSY and 13 C HSQC HR‐MAS spectra is comparable to that obtained on perchloric extracts. 13 C HSQC HR‐MAS spectra have been particularly useful for the identification of 37 different metabolites in intact biopsy tumours, excluding water and DSS components. To our knowledge, this is the most detailed assignment of biochemical compounds obtained in intact human tissue, in particular in brain tumour tissue. Tissue degradation during the recording of the NMR experiment was avoided by keeping the sample at a temperature of 4°C. Detailed metabolical compositions of 10 GBM (six primary, two secondary and two unclassified) were obtained. A good correlation between ex vivo and in vivo MRS has been found. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Metabolomics-based methods for early disease diagnostics
Gowda, G. N., Zhang, S., Gu, H., Asiago, V., Shanaiah, N., & Raftery, D. (2008) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.8.5.617 · Cited by 692
Andronesi, O. C., Kim, G. S., Gerstner, E., Batchelor, T., Tzika, A. A., Fantin, V. R., Vander Heiden, M. G., & Sorensen, A. G. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3002693 · Cited by 438
Metabolite profiling of fecal water extracts from human colorectal cancer
Monleón, D., Morales, J. M., Barrasa, A., López, J. A., Vázquez, C., & Celda, B. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1345 · Cited by 186
Self-citationApplications of metabolomics to study cancer metabolism
Kaushik, A. K., & DeBerardinis, R. J. (2018) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2018.04.009 · Cited by 179
Sitter, B., Bathen, T. F., Tessem, M.-B., & Gribbestad, I. S. (2009) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2008.10.001 · Cited by 91
Metadata
- Authors
- Martínez‐Bisbal, M. C., Martí‐Bonmatí, L., Piquer, J., Revert, A., Ferrer, P., Llácer, J. L., Piotto, M., Assemat, O., & Celda, B.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2004-06
- Volume
- 17
- Issue
- 4
- Pages
- 191-205
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2054325077
- Cited by
- 170
- References
- 0
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 1H and 13C HR‐MAS spectroscopy of intact biopsy samples ex vivo and in vivo1H MRS study of human high grade gliomas. https://app.cochat.ai/papers/10.1002/nbm.888
- The paper
- Martínez‐Bisbal, M. C., Martí‐Bonmatí, L., Piquer, J., Revert, A., Ferrer, P., Llácer, J. L., Piotto, M., Assemat, O., & Celda, B. (2004). 1H and 13C HR‐MAS spectroscopy of intact biopsy samples ex vivo and in vivo1H MRS study of human high grade gliomas. NMR in Biomedicine. https://doi.org/10.1002/nbm.888
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.