Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Multispectral imaging for quantitative and compartment‐specific immune infiltrates reveals distinct immune profiles that classify lung cancer patients

Mezheyeuski, Artur, Bergsland, Christian Holst, Backman, Max, Djureinovic, Dijana, Sjöblom, Tobias, Bruun, Jarle, Micke, Patrick·2018·The Journal of Pathology

Abstract

Semiquantitative assessment of immune markers by immunohistochemistry (IHC) has significant limitations for describing the diversity of the immune response in cancer. Therefore, we evaluated a fluorescence‐based multiplexed immunohistochemical method in combination with a multispectral imaging system to quantify immune infiltrates in situ in the environment of non‐small‐cell lung cancer (NSCLC). A tissue microarray including 57 NSCLC cases was stained with antibodies against CD8, CD20, CD4, FOXP3, CD45RO, and pan‐cytokeratin, and immune cells were quantified in epithelial and stromal compartments. The results were compared with those of conventional IHC, and related to corresponding RNA‐sequencing (RNAseq) expression values. We found a strong correlation between the visual and digital quantification of lymphocytes for CD45RO (correlation coefficient: r = 0.52), FOXP3 (r = 0.87), CD4 (r = 0.79), CD20 (r = 0.81) and CD8 (r = 0.90) cells. The correlation with RNAseq data for digital quantification (0.35–0.65) was comparable to or better than that for visual quantification (0.38–0.58). Combination of the signals of the five immune markers enabled further subpopulations of lymphocytes to be identified and localized. The specific pattern of immune cell infiltration based either on the spatial distribution (distance between regulatory CD8+ T and cancer cells) or the relationships of lymphocyte subclasses with each other (e.g. cytotoxic/regulatory cell ratio) were associated with patient prognosis. In conclusion, the fluorescence multiplexed immunohistochemical method, based on only one tissue section, provided reliable quantification and localization of immune cells in cancer tissue. The application of this technique to clinical biopsies can provide a basic characterization of immune infiltrates to guide clinical decisions in the era of immunotherapy. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/path.5026

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 183

Metadata

Authors
Mezheyeuski, A., Bergsland, C. H., Backman, M., Djureinovic, D., Sjöblom, T., Bruun, J., & Micke, P.
Venue
The Journal of Pathology
Publisher
Wiley
Published
2018-02-05
Volume
244
Issue
4
Pages
421-431
ISSN
  • 0022-3417 (ISSN-L)
  • 1096-9896
OpenAlex
W2781180031
Cited by
183
References
10
FWCI
6.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multispectral imaging for quantitative and compartment‐specific immune infiltrates reveals distinct immune profiles that classify lung cancer patients. https://app.cochat.ai/papers/10.1002/path.5026
The paper
Mezheyeuski, A., Bergsland, C. H., Backman, M., Djureinovic, D., Sjöblom, T., Bruun, J., & Micke, P. (2018). Multispectral imaging for quantitative and compartment‐specific immune infiltrates reveals distinct immune profiles that classify lung cancer patients. The Journal of Pathology. https://doi.org/10.1002/path.5026

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.