Systematic review of accuracy of fetal urine analysis to predict poor postnatal renal function in cases of congenital urinary tract obstruction
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Objective: To evaluate the clinical usefulness of analysis of fetal urine in the prediction of poor postnatal renal function in cases of congenital urinary tract obstruction. Methods: A systematic review was performed. We conducted extensive electronic searches (database inception–2006). The reference lists of articles obtained were searched for any further articles. Two reviewers independently selected the articles in which the accuracy of fetal urinalysis was evaluated to predict poor postnatal renal function. There were no language restrictions. Data were extracted on study characteristics, quality and results, to construct 2 × 2 tables. Likelihood ratios for positive (LR+) and negative (LR−) test results were generated for the different fetal urinary analytes at various thresholds. Results: There were 23 articles that met the selection criteria, including a total of 572 women and 63 2 × 2 tables. The two most accurate tests were calcium > 95th centile for gestation (LR + 6.65, 0.23–190.96; LR − 0.19, 0.05–0.74) and sodium > 95th centile for gestation (LR + 4.46, 1.71–11.6; LR − 0.39, 0.17–0.88). β 2‐microglobulin was found to be less accurate (LR + 2.92, 1.28–6.69; LR − 0.53, 0.24–1.17). Conclusion: The current evidence demonstrates that none of the analytes of fetal urine investigated so far can be shown to yield clinically significant accuracy to predict poor postnatal renal function. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Schwartz, G. J., Haycock, G. B., Edelmann, C. M., & Spitzer, A. (1976) · Pediatrics · doi:10.1542/peds.58.2.259 · Cited by 2,379
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Self-citationEmpirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Systematic reviews of evaluations of diagnostic and screening tests
(2001) · Europe PMC (PubMed Central) · Cited by 850
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Plasma creatinine and urea concentration in children: Normal values for age and sex
Schwartz, G. J., Haycock, G. B., Chir, B., & Spitzer, A. (1976) · The Journal of Pediatrics · doi:10.1016/s0022-3476(76)81125-0 · Cited by 215
Clark, T. (2003) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(03)00577-5 · Cited by 163
Diagnosis and outcome of fetal lower urinary tract obstruction in the northern region of England
Anumba, D. O., Scott, J. E., Plant, N. D., & Robson, S. C. (2005) · Prenatal Diagnosis · doi:10.1002/pd.1074 · Cited by 162
ANAEROBIC BACTERIA IN LOWER GENITAL-TRACT INFECTIONS
Fontaine, E. A., Taylor-Robinson, D., Borriello, S. P., Hanna, N. F., & Honour, P. (1982) · The Lancet · doi:10.1016/s0140-6736(82)91004-2 · Cited by 123
Reporting of measures of accuracy in systematic reviews of diagnostic literature
Honest, H., & Khan, K. S. (2002) · BMC Health Services Research · doi:10.1186/1472-6963-2-4 · Cited by 112
Self-citationSystematic reviews to evaluate diagnostic tests
Khan, K. S., Dinnes, J., & Kleijnen, J. (2001) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(00)00463-2 · Cited by 108
Self-citation
Metadata
- Authors
- Morris, R. K., Quinlan‐Jones, E., Kilby, M. D., & Khan, K. S.
- Venue
- Prenatal Diagnosis
- Publisher
- Wiley
- Published
- 2007-07-04
- Volume
- 27
- Issue
- 10
- Pages
- 900-911
- ISSN
- 0197-3851 (ISSN-L)
- 1097-0223
- OpenAlex
- W1968748498
- Cited by
- 197
- References
- 20
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.