The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
OLAV: Towards high‐throughput tandem mass spectrometry data identification
Abstract
Mass spectrometry combined with database searching has become the preferred method for identifying proteins in proteomics projects. Proteins are digested by one or several enzymes to obtain peptides, which are analyzed by mass spectrometry. We introduce a new family of scoring schemes, named OLAV, aimed at identifying peptides in a database from their tandem mass spectra. OLAV scoring schemes are based on signal detection theory, and exploit mass spectrometry information more extensively than previously existing schemes. We also introduce a new concept of structural matching that uses pattern detection methods to better separate true from false positives. We show the superiority of OLAV scoring schemes compared to MASCOT, a widely used identification program. We believe that this work introduces a new way of designing scoring schemes that are especially adapted to high‐throughput projects such as GeneProt large‐scale human plasma project, where it is impractical to check all identifications manually.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Keller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
Prediction of complete gene structures in human genomic DNA
Burge, C., & Karlin, S. (1997) · Journal of Molecular Biology · doi:10.1006/jmbi.1997.0951 · Cited by 4,228
Biological Sequence Analysis: Probabilistic Models of Proteins and Nucleic Acids
Durbin, R., Eddy, S. R., Krogh, A., & Mitchison, G. (1998) · Cambridge University Press eBooks · doi:10.1017/cbo9780511790492 · Cited by 3,246
The SWISS-PROT protein sequence database and its supplement TrEMBL in 2000
Bairoch, A. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.1.45 · Cited by 3,093
An Introduction to Signal Detection and Estimation
Poor, H. V. (1994) · Springer Texts in Electrical Engineering · doi:10.1007/978-1-4757-2341-0 · Cited by 2,659
Rapid identification of proteins by peptide-mass fingerprinting
Pappin, D. J. C., Hojrup, P., & Bleasby, A. J. (1993) · Current Biology · doi:10.1016/0960-9822(93)90195-t · Cited by 1,615
Henzel, W. J., Billeci, T. M., Stults, J. T., Wong, S. C., Grimley, C., & Watanabe, C. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.5011 · Cited by 1,305
The interpretation of collision‐induced dissociation tandem mass spectra of peptides
Papayannopoulos, I. A. (1995) · Mass Spectrometry Reviews · doi:10.1002/mas.1280140104 · Cited by 657
De Novo Peptide Sequencing via Tandem Mass Spectrometry
Dančík, V., Addona, T. A., Clauser, K. R., Vath, J. E., & Pevzner, P. A. (1999) · Journal of Computational Biology · doi:10.1089/106652799318300 · Cited by 595
McCormack, A. L., Schieltz, D. M., Goode, B., Yang, S., Barnes, G., Drubin, D., & Yates, J. R. (1997) · Analytical Chemistry · doi:10.1021/ac960799q · Cited by 523
Collision-induced fragmentation of (M + H)+ ions of peptides. Side chain specific sequence ions
Johnson, R. S., Martin, S. A., & BIEMANN, K. (1988) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(88)80060-0 · Cited by 481
Qscore: An algorithm for evaluating SEQUEST database search results
Moore, R. E., Young, M. K., & Lee, T. D. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00352-5 · Cited by 390
Spengler, B. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199711)32:10<1019::aid-jms595>3.0.co;2-g · Cited by 321
Statistical Methods in Bioinformatics
Ewens, W. J., & Grant, G. R. (2001) · Statistics for Biology and Health · doi:10.1007/978-1-4757-3247-4 · Cited by 308
Fragmentation of phosphopeptides in an ion trap mass spectrometer
DeGnore, J. P., & Qin, J. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00088-9 · Cited by 257
Field, H. I., Fenyö, D., & Beavis, R. C. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200201)2:1<36::aid-prot36>3.0.co;2-w · Cited by 217
Zhang, N., Aebersold, R., & Schwikowski, B. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200210)2:10<1406::aid-prot1406>3.0.co;2-9 · Cited by 213
SCOPE: a probabilistic model for scoring tandem mass spectra against a peptide database
Bafna, V., & Edwards, N. J. (2001) · Bioinformatics · doi:10.1093/bioinformatics/17.suppl_1.s13 · Cited by 208
Code Developments to Improve the Efficiency of Automated MS/MS Spectra Interpretation
Sadygov, R. G., Eng, J., Durr, E., Saraf, A., McDonald, H., MacCoss, M. J., & Yates, J. R. (2002) · Journal of Proteome Research · doi:10.1021/pr015514r · Cited by 204
Palmblad, M., Ramström, M., Markides, K. E., Håkansson, P., & Bergquist, J. (2002) · Analytical Chemistry · doi:10.1021/ac0256890 · Cited by 136
Thiede, B., Lamer, S., Mattow, J., Siejak, F., Dimmler, C., Rudel, T., & Jungblut, P. R. (2000) · Rapid Communications in Mass Spectrometry · Cited by 131
Peptide Sequence Motif Analysis of Tandem MS Data with the SALSA Algorithm
Liebler, D. C., Hansen, B. T., Davey, S. W., Tiscareno, L., & Mason, D. E. (2001) · Analytical Chemistry · doi:10.1021/ac0155512 · Cited by 64
Prediction of peptide retention times
Sakamoto, Y., Kawakami, N., & Sasagawa, T. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)94457-1 · Cited by 37
Cited by
Multiplex peptide stable isotope dimethyl labeling for quantitative proteomics
Boersema, P. J., Raijmakers, R., Lemeer, S., Mohammed, S., & Heck, A. J. R. (2009) · Nature Protocols · doi:10.1038/nprot.2009.21 · Cited by 1,357
Shilov, I. V., Seymour, S. L., Patel, A. A., Loboda, A., Tang, W. H., Keating, S. P., Hunter, C. L., Nuwaysir, L. M., & Schaeffer, D. A. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t600050-mcp200 · Cited by 1,298
Gene essentiality and synthetic lethality in haploid human cells
Blomen, V. A., Májek, P., Jae, L. T., Bigenzahn, J. W., Nieuwenhuis, J., Staring, J., Sacco, R., van Diemen, F. R., Olk, N., Stukalov, A., et al. (2015) · Science · doi:10.1126/science.aac7557 · Cited by 857
Self-citationSLC38A9 is a component of the lysosomal amino acid sensing machinery that controls mTORC1
Rebsamen, M., Pochini, L., Stasyk, T., de Araújo, M. E. G., Galluccio, M., Kandasamy, R. K., Snijder, B., Fauster, A., Rudashevskaya, E. L., Bruckner, M., et al. (2015) · Nature · doi:10.1038/nature14107 · Cited by 673
Assigning Significance to Peptides Identified by Tandem Mass Spectrometry Using Decoy Databases
Käll, L., Storey, J. D., MacCoss, M. J., & Noble, W. S. (2008) · Journal of Proteome Research · doi:10.1021/pr700600n · Cited by 607
Metadata
- Authors
- Colinge, J., Masselot, A., Giron, M., Dessingy, T., & Magnin, J.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2003-08
- Volume
- 3
- Issue
- 8
- Pages
- 1454-1463
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2113945996
- Cited by
- 297
- References
- 25
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.