The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Maximising sensitivity for detecting changes in protein expression: Experimental design using minimal CyDyes
Abstract
DIGE is a powerful tool for measuring changes in protein expression between samples. Here we assess the assumptions of normality and heterogeneity of variance that underlie the univariate statistical tests routinely used to detect proteins with expression changes. Furthermore, the technical variance experienced in a multigel experiment is assessed here and found to be reproducible within‐ and across‐sample types. Utilising the technical variance measured, a power study is completed for several ‘typical’ fold changes in expression commonly used as thresholds by researchers. Based on this study using DeCyder, guidance is given on the number of gel replicates that are needed for the experiment to have sufficient sensitivity to detect expression changes. A two‐dye system based on utilising just Cy3 and Cy5 was found to be more reproducible than the three‐dye system. A power and cost‐benefit analysis performed here suggests that the traditional three‐dye system would use fewer resources in studies where multiple samples are compared. Technical variance was shown to encompass both experimental and analytical noise and thus is dependent on the analytical software utilised. Data is provided as a resource to the community to assess alternative software and upgrades.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Huber, W., von Heydebreck, A., Sültmann, H., Poustka, A., & Vingron, M. (2002) · Bioinformatics · doi:10.1093/bioinformatics/18.suppl_1.s96 · Cited by 2,440
Cited by
Guidelines for the next 10 years of proteomics
Wilkins, M. R., Appel, R. D., Van Eyk, J. E., Chung, M. C. M., Görg, A., Hecker, M., Huber, L. A., Langen, H., Link, A. J., Paik, Y., et al. (2006) · PROTEOMICS · doi:10.1002/pmic.200500856 · Cited by 307
Difference gel electrophoresis
Timms, J. F., & Cramer, R. (2008) · PROTEOMICS · doi:10.1002/pmic.200800298 · Cited by 267
The state of the art in the analysis of two-dimensional gel electrophoresis images
Berth, M., Moser, F. M., Kolbe, M., & Bernhardt, J. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-007-1128-0 · Cited by 254
Chouchani, E. T., Hurd, T. R., Nadtochiy, S. M., Brookes, P. S., Fearnley, I. M., Lilley, K. S., Smith, R. A. J., & Murphy, M. P. (2010) · Biochemical Journal · doi:10.1042/bj20100633 · Cited by 137
Self-citation
Metadata
- Authors
- Karp, N. A., & Lilley, K. S.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2005-08
- Volume
- 5
- Issue
- 12
- Pages
- 3105-3115
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2047640782
- Cited by
- 195
- References
- 2
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maximising sensitivity for detecting changes in protein expression: Experimental design using minimal CyDyes. https://app.cochat.ai/papers/10.1002/pmic.200500083
- The paper
- Karp, N. A., & Lilley, K. S. (2005). Maximising sensitivity for detecting changes in protein expression: Experimental design using minimal CyDyes. PROTEOMICS. https://doi.org/10.1002/pmic.200500083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.