Capillary electrophoresis and isoelectric focusing in peptide and protein analysis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
CZE and CIEF of proteins have preceded, and accompanied, the birth of proteomics. Although they might not be fully exploited in massive proteomic analyses (especially those projects aiming at a deep discovery of possibly the entire proteome of a cell or subcellular organelles or biological fluids), it still has interesting features and advantages, especially with samples of limited heterogeneity and in the field of purity checking for recombinant DNA proteins meant for human consumption. The purpose of this tutorial paper is to guide the reader through the history of the field, then through the main steps of the process, from sample preparation to analysis of proteins and peptides, while commenting on the constraints and caveats of the technique. The tutorial ends with an outlook on the future, which might be dominated by microchip electrophoresis, especially for ultrafast analyses of protein samples in a sieving mode, in presence of either sieving liquid polymers or firm gels polymerized within the microchannels. To this purpose, commercial instrumentation is already available on the market. This tutorial is part of the International Proteomics Tutorial Programme (IPTP 13).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein separation by capillary gel electrophoresis: A review
Zhu, Z., Lu, J. J., & Liu, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.10.022 · Cited by 202 · cited 1×
“[121], to which the readers are referred for further insight on these matters.”
Background
Cited by
Optimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95
“Protein loss caused by intact protein adsorption on the inner wall of capillary has been an issue for CZE analysis [24].”
MethodCE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
Zhao, Y., Sun, L., Zhu, G., & Dovichi, N. J. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00493 · Cited by 61
Quantitative Proteomics Using Ultralow Flow Capillary Electrophoresis–Mass Spectrometry
Faserl, K., Kremser, L., Müller, M., Teis, D., & Lindner, H. H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00312 · Cited by 57
Zhao, Y., Sun, L., Knierman, M. D., & Dovichi, N. J. (2016) · Talanta · doi:10.1016/j.talanta.2015.11.020 · Cited by 49
Metadata
- Authors
- Righetti, P. G., Sebastiano, R., & Citterio, A.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2012-12-23
- Volume
- 13
- Issue
- 2
- Pages
- 325-340
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2063912727
- Cited by
- 166
- References
- 1
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.