Fast separation and analysis of reduced monoclonal antibodies with capillary zone electrophoresis coupled to mass spectrometry
Abstract
Capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) was used for analysis of reduced antibodies. We first developed a simple protocol to condition commercial linear-polyacrylamide coated capillaries for use in top-down proteomics. We then suspended reduced antibodies in a solution of 35% acetic acid, 50% acetonitrile in water. Heavy and light chains were baseline resolved within 10 min and with 3-30 µg/mL detection limits using a 0.1% aqueous formic acid background electrolyte. Quintuplicate runs of a two-antibody mixture produced relative standard deviations of ∼1% in migration time and 10% in peak amplitudes. Resolution was further improved for the two-antibody mixture by using 5% acetic acid as the background electrolyte, highlighting the potential of capillary electrophoresis-mass spectrometry for analysis of antibody mixtures.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Notable CZE-MS examples include intact mass analysis of biopharmaceutical proteins and monoclonal antibodies, where complete baseline separation is often achieved.
“Notable examples of CZE-MS include the intact mass analysis of biopharmaceutical proteins11 and monoclonal antibodies22,68 where complete baseline separation is often achieved.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [68]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149 · see citing works
Li, Y., Champion, M. M., Sun, L., Champion, P. A. D., Wojcik, R., & Dovichi, N. J. (2012) · Analytical Chemistry · doi:10.1021/ac202899p · Cited by 128 · see citing works
Self-citationOptimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95 · see citing works
Han, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R. (2014) · Analytical Chemistry · doi:10.1021/ac503439n · Cited by 77 · see citing works
Zhao, Y., Sun, L., Champion, M. M., Knierman, M. D., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac500092q · Cited by 56 · see citing works
Self-citationZhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55 · see citing works
Self-citationHeemskerk, A. A. M., Wuhrer, M., Busnel, J., Koeleman, C. A. M., Selman, M. H. J., Vidarsson, G., Kapur, R., Schoenmaker, B., Derks, R. J. E., Deelder, A. M., et al. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200357 · Cited by 43 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Dai, J., Lamp, J., Xia, Q., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04608 · Cited by 123 · see citing works
Ion Activation Methods for Peptides and Proteins
Macias, L. A., Santos, I. C., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04859 · Cited by 107 · see citing works
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112 · see citing works
Zhao, Y., Sun, L., Zhu, G., & Dovichi, N. J. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00493 · Cited by 61 · see citing works
Self-citationZhu, G., Sun, L., & Dovichi, N. J. (2016) · The Analyst · doi:10.1039/c6an01140c · Cited by 52 · see citing works
Self-citationYu, D., Wang, Z., Cupp-Sutton, K. A., Liu, X., & Wu, S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02315-2 · Cited by 39 · see citing works
Peuchen, E. H., Zhu, G., Sun, L., & Dovichi, N. J. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0122-8 · Cited by 30 · see citing works
Self-citationDada, O. O., Zhao, Y., Jaya, N., & Salas-Solano, O. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03405 · Cited by 20 · see citing works
Self-citation
- Authors
- Zhao, Y., Sun, L., Knierman, M. D., & Dovichi, N. J.
- Affiliations
- University of Notre Dame (US)
- Eli Lilly (United States) (US)
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 148
- Pages
- 529-533
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2133061982
- Cited by
- 49
- References
- 7
- Citations by year
- 2024: 4 · 2023: 4 · 2022: 1 · 2021: 10 · 2020: 2 · 2019: 6 · 2018: 5 · 2017: 6 · 2016: 10 · 2015: 1
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eli Lilly and Company
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- capillary zone electrophoresis, top-down proteomics, antibody heavy and light chains, background electrolyte optimization, antibody mixtures
- MeSH terms
- Antibodies, Monoclonal, Time Factors, Electrophoresis, Capillary, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review