Cited by 86Neuroscience and Neural EngineeringElectrospun Nanofibers in Biomedical ApplicationsAdvanced Sensor and Energy Harvesting Materials

Flexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing

Heo, Dong Nyoung, Kim, Han-Jun, Lee, Yi Jae, Heo, Min, Lee, Sang Jin, Lee, Donghyun, Do, Sun Hee, Lee, Soo Hyun +1 more·2017·ACS Nano

Abstract

Polyimide (PI)-based electrodes have been widely used as flexible biosensors in implantable device applications for recording biological signals. However, the long-term quality of neural signals obtained from PI-based nerve electrodes tends to decrease due to nerve damage by neural tissue compression, mechanical mismatch, and insufficient fluid exchange between the neural tissue and electrodes. Here, we resolve these problems with a developed PI nanofiber (NF)-based nerve electrode for stable neural signal recording, which can be fabricated via electrospinning and inkjet printing. We demonstrate an NF-based nerve electrode that can be simply fabricated and easily applied due to its high permeability, flexibility, and biocompatibility. Furthermore, the electrode can record stable neural signals for extended periods of time, resulting in decreased mechanical mismatch, neural compression, and contact area. NF-based electrodes with highly flexible and body-fluid-permeable properties could enable future neural interfacing applications.

Integrity signals

Registry

Crossref · 10.1021/acsnano.6b08390

Cites

62 of 62 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Heo, D. N., Kim, H.-J., Lee, Y. J., Heo, M., Lee, S. J., Lee, D., Do, S. H., Lee, S. H., & Kwon, I. K.
Affiliations
  • George Washington University (US)
  • Konkuk University (KR)
  • Korea Institute of Science and Technology (KR)
  • Kyung Hee University (KR)
Corresponding author
  • Do, Sun Hee
  • Lee, Soo Hyun
  • Kwon, Il Keun
Venue
ACS Nano
Published
2017-02-17
Volume
11
Issue
3
Pages
2961-2971
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2588510267
Cited by
86
References
62
Citations by year
2026: 5 · 2025: 11 · 2024: 7 · 2023: 11 · 2022: 14 · 2021: 12 · 2020: 6 · 2019: 8 · 2018: 8 · 2017: 4
FWCI
3.48
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Korea Health Industry Development Institute (HI14C2241)
  • National Research Foundation of Korea (NRF-2012R1A5A2051388, NRF-2014R1A1A3052557)
  • Korea Institute of Science and Technology (2E26180)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
polyimide nanofibers, neural recording, flexible electrodes, biocompatibility, electrospinning, inkjet printing, mechanical mismatch, long-term neural recording
MeSH terms
Animals, Biocompatible Materials, Electrodes, Male, Nerve Tissue, Resins, Synthetic, Surface Properties, Rats, Sprague-Dawley, Rats, Nanofibers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review