The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Assessment of the Physicochemical Properties and Biological Effects of Water Activated by Non‐thermal Plasma Above and Beneath the Water Surface
Abstract
A direct current atmospheric pressure cold plasma microjet (PMJ) was used to produce plasma activated water (PAW) in two generation modes above (PAW‐A) and beneath (PAW‐B) the water surface. The physicochemical characteristics and biological effects of them were measured respectively. Results showed that PAW‐B exhibited stronger disinfection efficiency than PAW‐A, which was associated with ORP and conductivity, but not pH value, temperature, H 2 O 2, NO 3− or NO 2−. Furthermore, the cell membrane integrity and membrane potential of S. aureus were destroyed more severely by PAW‐B. More importantly, a significant increase of intracellular ROS was induced by PAW‐B, which was supposed to contribute most to the sterilization. This work provides valuable guidance for the production and wide applications of PAW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Sensenig, R., Kalghatgi, S., Cerchar, E., Fridman, G., Shereshevsky, A., Torabi, B., Arjunan, K. P., Podolsky, E., Fridman, A., Friedman, G., et al. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0197-x · Cited by 166
RetractedFree Radicals in Biology and Medicine
Halliwell, B., & Gutteridge, J. M. C. (2015) · doi:10.1093/acprof:oso/9780198717478.001.0001 · Cited by 8,990
Lukes, P., Dolezalova, E., Sisrova, I., & Clupek, M. (2014) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/23/1/015019 · Cited by 1,181
Non-thermal atmospheric pressure discharges
Fridman, A., Chirokov, A., & Gutsol, A. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/2/r01 · Cited by 1,005
Berney, M., Hammes, F., Bosshard, F., Weilenmann, H.-U., & Egli, T. (2007) · Applied and Environmental Microbiology · doi:10.1128/aem.02750-06 · Cited by 924
Involvement of Nitric Oxide in Biofilm Dispersal of Pseudomonas aeruginosa
Barraud, N., Hassett, D. J., Hwang, S.-H., Rice, S. A., Kjelleberg, S., & Webb, J. S. (2006) · Journal of Bacteriology · doi:10.1128/jb.00779-06 · Cited by 783
Laroussi, M. (2002) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2002.804220 · Cited by 760
The Role of Acidification for Antimicrobial Activity of Atmospheric Pressure Plasma in Liquids
Oehmigen, K., Hähnel, M., Brandenburg, R., Wilke, C., Weltmann, K. ‐., & von Woedtke, T. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900077 · Cited by 726
Non-thermal plasma technologies: New tools for bio-decontamination
Moreau, M., Orange, N., & Feuilloley, M. G. J. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.08.001 · Cited by 657
Weinstein, R. A., & Hota, B. (2004) · Clinical Infectious Diseases · doi:10.1086/424667 · Cited by 635
Ikawa, S., Kitano, K., & Hamaguchi, S. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900090 · Cited by 568
Joshi, S. G., Cooper, M., Yost, A., Paff, M., Ercan, U. K., Fridman, G., Friedman, G., Fridman, A., & Brooks, A. D. (2011) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01002-10 · Cited by 523
Long-term antibacterial efficacy of air plasma-activated water
Traylor, M. J., Pavlovich, M. J., Karim, S., Hait, P., Sakiyama, Y., Clark, D. S., & Graves, D. B. (2011) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/44/47/472001 · Cited by 490
Cold atmospheric pressure air plasma jet for medical applications
Kolb, J. F., Mohamed, A.-A. H., Price, R. O., Swanson, R. J., Bowman, A., Chiavarini, R. L., Stacey, M., & Schoenbach, K. H. (2008) · Applied Physics Letters · doi:10.1063/1.2940325 · Cited by 430
van Gils, C. A. J., Hofmann, S., Boekema, B. K. H. L., Brandenburg, R., & Bruggeman, P. J. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/17/175203 · Cited by 346
Naïtali, M., Kamgang-Youbi, G., Herry, J.-M., Bellon-Fontaine, M.-N., & Brisset, J.-L. (2010) · Applied and Environmental Microbiology · doi:10.1128/aem.01615-10 · Cited by 318
Novo, D., Perlmutter, N. G., Hunt, R. H., & Shapiro, H. M. (1999) · Cytometry · doi:10.1002/(sici)1097-0320(19990101)35:1<55::aid-cyto8>3.0.co;2-2 · Cited by 303
Collos, Y., Mornet, F., Sciandra, A., Waser, N., Larson, A., & Harrison, P. J. (1999) · Journal of Applied Phycology · doi:10.1023/a:1008046023487 · Cited by 272
Novo, D. J., Perlmutter, N. G., Hunt, R. H., & Shapiro, H. M. (2000) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.44.4.827-834.2000 · Cited by 261
Pavlovich, M. J., Chang, H.-W., Sakiyama, Y., Clark, D. S., & Graves, D. B. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/14/145202 · Cited by 259
Lee, K.-N., Paek, K.-H., Ju, W.-T., & Lee, Y. (2006) · PubMed · Cited by 252
Liu, F., Sun, P., Bai, N., Tian, Y., Zhou, H., Wei, S., Zhou, Y., Zhang, J., Zhu, W., Becker, K., et al. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900070 · Cited by 235
Self-citationMicrobial inactivation using plasma-activated water obtained by gliding electric discharges
Kamgang-Youbi, G., Herry, J.-M., Meylheuc, T., Brisset, J.-L., Bellon-Fontaine, M.-N., Doubla, A., & Naïtali, M. (2009) · Letters in Applied Microbiology · doi:10.1111/j.1472-765x.2008.02476.x · Cited by 226
A study of oxidative stress induced by non-thermal plasma-activated water for bacterial damage
Zhang, Q., Liang, Y., Feng, H., Ma, R., Tian, Y., Zhang, J., & Fang, J. (2013) · Applied Physics Letters · doi:10.1063/1.4807133 · Cited by 217
Self-citationGlobal Model of He/O2 and Ar/O2 Atmospheric Pressure Glow Discharges
Park, G., Lee, H., Kim, G.-C., & Lee, J. K. (2008) · Plasma Processes and Polymers · doi:10.1002/ppap.200800019 · Cited by 184
Joshi, S. G., Paff, M., Friedman, G., Fridman, G., Fridman, A., & Brooks, A. D. (2010) · American Journal of Infection Control · doi:10.1016/j.ajic.2009.11.002 · Cited by 184
Membrane Potential Estimation by Flow Cytometry
Shapiro, H. M. (2000) · Methods · doi:10.1006/meth.2000.1007 · Cited by 174
Opinion on the use of plasma processes for treatment of foods*
Schlüter, O., Ehlbeck, J., Hertel, C., Habermeyer, M., Roth, A., Engel, K.-H., Holzhauser, T., Knorr, D., & Eisenbrand, G. (2013) · Molecular Nutrition & Food Research · doi:10.1002/mnfr.201300039 · Cited by 173
Leuko, S., Legat, A., Fendrihan, S., & Stan‐Lotter, H. (2004) · Applied and Environmental Microbiology · doi:10.1128/aem.70.11.6884-6886.2004 · Cited by 126
Ercan, U. K., Wang, H., Ji, H., Fridman, G., Brooks, A. D., & Joshi, S. G. (2013) · Plasma Processes and Polymers · doi:10.1002/ppap.201200104 · Cited by 125
Biofilm formation by Scottish clinical isolates of Staphylococcus aureus
Smith, K., Perez, A., Ramage, G., Lappin, D. F., Gemmell, C. G., & Lang, S. (2008) · Journal of Medical Microbiology · doi:10.1099/jmm.0.2008/000968-0 · Cited by 114
Kamgang‐Youbi, G., Herry, J., Brisset, J., Bellon‐Fontaine, M., Doubla, A., & Naïtali, M. (2008) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-008-1641-9 · Cited by 109
Ma, R. N., Feng, H., Liang, Y., Zhang, Q., Tian, Y., Su, B., Zhang, J., & Fang, J. (2013) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/46/28/285401 · Cited by 87
Self-citationZhang, Q., Sun, P., Feng, H., Wang, R., Liang, Y., Zhu, W., Becker, K. H., Zhang, J., & Fang, J. (2012) · Journal of Applied Physics · doi:10.1063/1.4730627 · Cited by 70
Self-citationDBD plasma source operated in single-filamentary mode for therapeutic use in dermatology
Rajasekaran, P., Mertmann, P., Bibinov, N. K., Wandke, D., Viöl, W., & Awakowicz, P. (2009) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/42/22/225201 · Cited by 60
Zhang, Q., Wang, R., Zhang, J., Fang, J., Sun, P., Feng, H., Liang, Y., Zhu, Y., & Becker, K. H. (2012) · IEEE International Conference on Plasma Science (ICOPS) · doi:10.1109/plasma.2012.6383784 · Cited by 56
Self-citationOxidative stress and chronological aging in glycogen-phosphorylase-deleted yeast
Favre, C., Aguilar, P. S., & Carrillo, M. C. (2008) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2008.08.021 · Cited by 45
Schnabel, U., Andrasch, M., Weltmann, K., & Ehlbeck, J. (2013) · Plasma Processes and Polymers · doi:10.1002/ppap.201300072 · Cited by 43
Ma, R., Feng, H., Li, F., Liang, Y., Zhang, Q., Zhu, W., Zhang, J., Becker, K. H., & Fang, J. (2012) · Applied Physics Letters · doi:10.1063/1.3693165 · Cited by 35
Self-citation
Cited by
Thirumdas, R., Kothakota, A., Annapure, U., Siliveru, K., Blundell, R., Gatt, R., & Valdramidis, V. P. (2018) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2018.05.007 · Cited by 938
Metadata
- Authors
- Tian, Y., Ma, R., Zhang, Q., Feng, H., Liang, Y., Zhang, J., & Fang, J.
- Venue
- Plasma Processes and Polymers
- Publisher
- Wiley
- Published
- 2014-12-28
- Volume
- 12
- Issue
- 5
- Pages
- 439-449
- ISSN
- 1612-8850 (ISSN-L)
- 1612-8869
- OpenAlex
- W2095804773
- Cited by
- 263
- References
- 39
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.