A review of proton therapy – Current status and future directions
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
The original rationale for proton therapy was its highly conformal depth‐dose distributions compared to photons, which allow greater sparing of normal tissues and escalation of tumor doses, thus potentially improving outcomes. Additionally, recent research has revealed previously unrecognized advantages of proton therapy. For instance, the higher relative biological effectiveness (RBE) near the end of the proton range can be exploited to increase the difference in biologically effective dose in tumors versus normal tissues. Moreover, the smaller “dose bath,” that is, the compact nature of proton dose distributions, has been found to reduce the exposure of circulating lymphocytes and the immune organs at risk. There is emerging evidence that the resulting sparing of the immune system has the potential to improve outcomes. Protons accelerated to energies ranging from 70 to 250 MeV enter the treatment head mounted typically on a rotating gantry. Initially, the beams of protons are narrow and, to be suitable for treatments, must be spread laterally and longitudinally and shaped appropriately. Such spreading and shaping may be accomplished electro‐mechanically for the “passively scattered proton therapy” (PSPT) mode; or it may be achieved through magnetic scanning of thin “beamlets” of protons. Intensities of scanning beamlets are optimized to deliver intensity‐modulated proton therapy (IMPT), which optimally balances tumor dose and the sparing of normal tissues. IMPT is presumably the most powerful form of proton therapy. The planning and evaluation of proton dose distributions require substantially different techniques compared to photon therapy. This is mainly due to the fact that proton dose distributions are highly sensitive to inter‐ and intra‐fractional variations in anatomy. In addition, for the same physical dose, the biological effectiveness of protons is different from photons. In the current practice of proton therapy, the RBE is simplistically assumed to have a constant value of 1.1. In reality, the RBE is variable and a highly complex function of numerous variables including energy of protons, dose per fraction, tissue and its environment, cell type, end point, and possibly other factors. While the theoretical potential of proton therapy is high, the clinical evidence in support of its use has so far been mixed. The uncertainties and assumptions mentioned above and the limitations of the still evolving technology of proton therapy may have diminished its true clinical potential. Although promising results have been reported for many types of cancers, they are often based on small studies. At the same time, there have been reports of unforeseen toxicities. Furthermore, because of the high cost of proton therapy, questions are often raised about its value. The general consensus is that there is a need for continued improvement in the state of the art of proton therapy. There is also a need to generate high level evidence of the potential of protons. Fortuitously, such efforts are taking place currently. Current research, aimed at enhancing the therapeutic potential of proton therapy, includes the determination and mitigation of the impact of the physical uncertainties on proton dose distributions through advanced image‐guidance and adaptive radiotherapy techniques. Since residual uncertainties will remain, robustness evaluation and robust optimization techniques are being developed to render dose distributions more resilient and to improve confidence in them. The ongoing research also includes improving our understanding of the biological and immunomodulatory effects of proton therapy. Such research and continuing technological advancements in planning and delivery methods are likely to help demonstrate the superiority of protons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403 · cited 1×
“Historically, the therapeutic potential of protons was first recognized byWilson in 1946.[1] The first patient was treatedwith proton therapy in 1954 employing the synchrocyclotron at the University of California, Berkley.”
MethodRelative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364 · cited 1×
“1.[10,9] This value of RBE is based on an average of the results”
BackgroundPaganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915 · cited 1×
“1.[10,9] This value of RBE is based on an average of the results”
BackgroundProton therapy – Present and future
Mohan, R., & Grosshans, D. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.11.006 · Cited by 608
Self-citationLangendijk, J. A., Lambin, P., De Ruysscher, D., Widder, J., Bos, M., & Verheij, M. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.05.007 · Cited by 549
Ku, G. Y., Yuan, J., Page, D. B., Schroeder, S. E. A., Panageas, K. S., Carvajal, R. D., Chapman, P. B., Schwartz, G. K., Allison, J. P., & Wolchok, J. D. (2010) · Cancer · doi:10.1002/cncr.24951 · Cited by 422
Yovino, S., Kleinberg, L., Grossman, S. A., Narayanan, M., & Ford, E. (2013) · Cancer Investigation · doi:10.3109/07357907.2012.762780 · Cited by 417 · cited 1×
“Lymphocytes are highly radiosensitive (LD50 <2 Gy) [97,98] and are killed by radiation in much greater numbers than other cells, resulting in radiation-induced lymphopenia (RIL), which has been shown to be associated with inferior radiotherapy outcomes.”
BackgroundGoitein, M., Abrams, M., Rowell, D., Pollari, H., & Wiles, J. (1983) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(83)90003-2 · Cited by 392 · cited 1×
“in the early 1980s to develop a three-dimensional (3D) conformal radiotherapy planning for protons is most notable.[21,22] In the following two decades, the state-of-the-art of proton therapy planning remained relatively static.”
BackgroundRobust optimization of intensity modulated proton therapy: Robust optimization of IMPT
Liu, W., Zhang, X., Li, Y., & Mohan, R. (2012) · Medical Physics · doi:10.1118/1.3679340 · Cited by 354
Self-citationMcNamara, A. L., Schuemann, J., & Paganetti, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/8399 · Cited by 345
Cited by
Enhancing Proton Therapy Efficacy Through Nanoparticle-Mediated Radiosensitization
Ma, J., Shen, H., & Mi, Z. (2024) · Cells · doi:10.3390/cells13221841 · Cited by 23
Metadata
- Authors
- Mohan, R.
- Venue
- Precision Radiation Oncology
- Publisher
- Wiley
- Published
- 2022-04-27
- Volume
- 6
- Issue
- 2
- Pages
- 164-176
- ISSN
- 2398-7324 (ISSN-L)
- OpenAlex
- W4293021298
- Cited by
- 248
- References
- 55
- FWCI
- 25.65
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.