A review of proton therapy – Current status and future directions
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
The original rationale for proton therapy was its highly conformal depth‐dose distributions compared to photons, which allow greater sparing of normal tissues and escalation of tumor doses, thus potentially improving outcomes. Additionally, recent research has revealed previously unrecognized advantages of proton therapy. For instance, the higher relative biological effectiveness (RBE) near the end of the proton range can be exploited to increase the difference in biologically effective dose in tumors versus normal tissues. Moreover, the smaller “dose bath,” that is, the compact nature of proton dose distributions, has been found to reduce the exposure of circulating lymphocytes and the immune organs at risk. There is emerging evidence that the resulting sparing of the immune system has the potential to improve outcomes. Protons accelerated to energies ranging from 70 to 250 MeV enter the treatment head mounted typically on a rotating gantry. Initially, the beams of protons are narrow and, to be suitable for treatments, must be spread laterally and longitudinally and shaped appropriately. Such spreading and shaping may be accomplished electro‐mechanically for the “passively scattered proton therapy” (PSPT) mode; or it may be achieved through magnetic scanning of thin “beamlets” of protons. Intensities of scanning beamlets are optimized to deliver intensity‐modulated proton therapy (IMPT), which optimally balances tumor dose and the sparing of normal tissues. IMPT is presumably the most powerful form of proton therapy. The planning and evaluation of proton dose distributions require substantially different techniques compared to photon therapy. This is mainly due to the fact that proton dose distributions are highly sensitive to inter‐ and intra‐fractional variations in anatomy. In addition, for the same physical dose, the biological effectiveness of protons is different from photons. In the current practice of proton therapy, the RBE is simplistically assumed to have a constant value of 1.1. In reality, the RBE is variable and a highly complex function of numerous variables including energy of protons, dose per fraction, tissue and its environment, cell type, end point, and possibly other factors. While the theoretical potential of proton therapy is high, the clinical evidence in support of its use has so far been mixed. The uncertainties and assumptions mentioned above and the limitations of the still evolving technology of proton therapy may have diminished its true clinical potential. Although promising results have been reported for many types of cancers, they are often based on small studies. At the same time, there have been reports of unforeseen toxicities. Furthermore, because of the high cost of proton therapy, questions are often raised about its value. The general consensus is that there is a need for continued improvement in the state of the art of proton therapy. There is also a need to generate high level evidence of the potential of protons. Fortuitously, such efforts are taking place currently. Current research, aimed at enhancing the therapeutic potential of proton therapy, includes the determination and mitigation of the impact of the physical uncertainties on proton dose distributions through advanced image‐guidance and adaptive radiotherapy techniques. Since residual uncertainties will remain, robustness evaluation and robust optimization techniques are being developed to render dose distributions more resilient and to improve confidence in them. The ongoing research also includes improving our understanding of the biological and immunomodulatory effects of proton therapy. Such research and continuing technological advancements in planning and delivery methods are likely to help demonstrate the superiority of protons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403 · cited 1×
“Historically, the therapeutic potential of protons was first recognized byWilson in 1946.[1] The first patient was treatedwith proton therapy in 1954 employing the synchrocyclotron at the University of California, Berkley.”
MethodRelative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364 · cited 1×
“1.[10,9] This value of RBE is based on an average of the results”
BackgroundPaganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915 · cited 1×
“1.[10,9] This value of RBE is based on an average of the results”
BackgroundProton therapy – Present and future
Mohan, R., & Grosshans, D. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.11.006 · Cited by 608
Self-citationLangendijk, J. A., Lambin, P., De Ruysscher, D., Widder, J., Bos, M., & Verheij, M. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.05.007 · Cited by 549
Ku, G. Y., Yuan, J., Page, D. B., Schroeder, S. E. A., Panageas, K. S., Carvajal, R. D., Chapman, P. B., Schwartz, G. K., Allison, J. P., & Wolchok, J. D. (2010) · Cancer · doi:10.1002/cncr.24951 · Cited by 422
Yovino, S., Kleinberg, L., Grossman, S. A., Narayanan, M., & Ford, E. (2013) · Cancer Investigation · doi:10.3109/07357907.2012.762780 · Cited by 417 · cited 1×
“Lymphocytes are highly radiosensitive (LD50 <2 Gy) [97,98] and are killed by radiation in much greater numbers than other cells, resulting in radiation-induced lymphopenia (RIL), which has been shown to be associated with inferior radiotherapy outcomes.”
BackgroundGoitein, M., Abrams, M., Rowell, D., Pollari, H., & Wiles, J. (1983) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(83)90003-2 · Cited by 392 · cited 1×
“in the early 1980s to develop a three-dimensional (3D) conformal radiotherapy planning for protons is most notable.[21,22] In the following two decades, the state-of-the-art of proton therapy planning remained relatively static.”
BackgroundRobust optimization of intensity modulated proton therapy: Robust optimization of IMPT
Liu, W., Zhang, X., Li, Y., & Mohan, R. (2012) · Medical Physics · doi:10.1118/1.3679340 · Cited by 354
Self-citationMcNamara, A. L., Schuemann, J., & Paganetti, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/8399 · Cited by 345
Liao, Z., Lee, J. J., Komaki, R., Gomez, D. R., O’Reilly, M. S., Fossella, F. V., Blumenschein, G. R., Heymach, J. V., Vaporciyan, A. A., Swisher, S. G., et al. (2018) · Journal of Clinical Oncology · doi:10.1200/jco.2017.74.0720 · Cited by 336 · cited 1×
“[27,51–53] However, in a first of its kind randomized phase II trial of IMRT versus PSPT of locally advanced non-small cell lung cancers, which completed accrual in 2014 and for which results were reported in 2018, there was no difference in either of the primary end points of local control or grade 3 pneumonitis.[54]…”
BackgroundSelf-citationGrossman, S. A., Ellsworth, S., Campian, J., Wild, A. T., Herman, J. M., Laheru, D., Brock, M., Balmanoukian, A., & Ye, X. (2015) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2015.0151 · Cited by 310
Lin, S. H., Hobbs, B. P., Verma, V., Tidwell, R. S. S., Smith, G. L., Lei, X. J., Corsini, E. M., Mok, I., Wei, X., Yao, L., et al. (2020) · Journal of Clinical Oncology · doi:10.1200/jco.19.02503 · Cited by 289 · cited 1×
“Based on these findings, a multi-institutional randomized trial of protons versus photons for esophageal cancerwas conducted.[66] This trial (N = 145) showed no difference in survival; however, the total toxicity burden, defined as a composite score of 11 distinct adverse events, was 2.”
BackgroundSelf-citationAres, C., Hug, E. B., Lomax, A. J., Bolsi, A., Timmermann, B., Rutz, H. P., Schuller, J. C., Pedroni, E., & Goitein, G. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.12.055 · Cited by 279 · cited 1×
“Notably, investigators from the Paul Scherrer Institute achieved excellent outcomes using IMPT for patients with skull-based lesions.[40] Early results with the use of IMPT from MD Anderson[41] reported improved dose distributions compared to PSPT and favorable disease control and toxicity profiles.”
Peeler, C. R., Mirkovic, D., Titt, U., Blanchard, P., Gunther, J. R., Mahajan, A., Mohan, R., & Grosshans, D. R. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.11.001 · Cited by 271
Self-citationWedenberg, M., Lind, B. K., & Hårdemark, B. (2013) · Acta Oncologica · doi:10.3109/0284186x.2012.705892 · Cited by 269
(1979) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/63.5.1229 · Cited by 263 · cited 1×
“The effectiveness of cancer therapy, including radiotherapy, relies on an intact immune system.[96] However, RT suppresses the immune sys-”
BackgroundPatel, S. H., Wang, Z., Wong, W. W., Murad, M. H., Buckey, C. R., Mohammed, K., Alahdab, F., Altayar, O., Nabhan, M., Schild, S. E., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70268-2 · Cited by 262 · cited 1×
“suggested improved survival outcomeswith particle therapy compared to photon therapy.[42]”
BackgroundLymphocyte Nadir and Esophageal Cancer Survival Outcomes After Chemoradiation Therapy
Davuluri, R., Jiang, W., Fang, P., Xu, C., Komaki, R., Gomez, D. R., Welsh, J., Cox, J. D., Crane, C. H., Hsu, C. C., et al. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.05.037 · Cited by 257 · cited 1×
“attributable to its smaller dose bath, is the sparing of the immune system.[106] However, significant further sparing may be possible through an improved understanding of the dependence of RIL on baseline patient specific clinical factors and dose distribution patterns and the development of RIL risk predictionmodels.”
BackgroundA treatment planning inter-comparison of proton and intensity modulated photon radiotherapy
Lomax, A. J., Bortfeld, T., Goitein, G., Debus, J., Dykstra, C., Tercier, P.-A., Coucke, P. A., & Mirimanoff, R. O. (1999) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(99)00036-5 · Cited by 245
Wild, A. T., Herman, J. M., Dholakia, A. S., Moningi, S., Lu, Y., Rosati, L. M., Hacker-Prietz, A., Assadi, R. K., Saeed, A. M., Pawlik, T. M., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.11.026 · Cited by 228
Multi-dimensional treatment planning: I. Delineation of anatomy
Goitein, M., & Abrams, M. (1983) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(83)90002-0 · Cited by 213 · cited 1×
“in the early 1980s to develop a three-dimensional (3D) conformal radiotherapy planning for protons is most notable.[21,22] In the following two decades, the state-of-the-art of proton therapy planning remained relatively static.”
BackgroundA phenomenological model for the relative biological effectiveness in therapeutic proton beams
Wilkens, J. J., & Oelfke, U. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/13/004 · Cited by 212
Incidence and dosimetric parameters of pediatric brainstem toxicity following proton therapy
Indelicato, D. J., Flampouri, S., Rotondo, R. L., Bradley, J. A., Morris, C. G., Aldana, P. R., Sandler, E., & Mendenhall, N. P. (2014) · Acta Oncologica · doi:10.3109/0284186x.2014.957414 · Cited by 212 · cited 1×
“It is also notable that several studies have shown unanticipated severe toxicities in proton therapy of brain tumors.[34,36,37,47] The higher RBE around the distal edge has been implicated and has been and continues to be investigated in retrospective studies[35,48–50]”
BackgroundWild, A. T., Ye, X., Ellsworth, S. G., Smith, J. A., Narang, A. K., Garg, T., Campian, J., Laheru, D. A., Zheng, L., Wolfgang, C. L., et al. (2015) · American Journal of Clinical Oncology · doi:10.1097/coc.0b013e3182940ff9 · Cited by 211
Brainstem tolerance to conformal radiotherapy of skull base tumors
Debus, J., Hug, E. B., Liebsch, N. J., O'Farrel, D., Finkelstein, D., Efird, J., & Munzenrider, J. E. (1997) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(97)00364-7 · Cited by 208 · cited 1×
“Published studies have shown high disease control and acceptable toxicity rates with proton therapy.[38,39] Themajority of patients in these studies received PSPT.”
BackgroundHaas-Kogan, D., Indelicato, D., Paganetti, H., Esiashvili, N., Mahajan, A., Yock, T., Flampouri, S., MacDonald, S., Fouladi, M., Stephen, K., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.01.013 · Cited by 182 · cited 1×
“It is also notable that several studies have shown unanticipated severe toxicities in proton therapy of brain tumors.[34,36,37,47] The higher RBE around the distal edge has been implicated and has been and continues to be investigated in retrospective studies[35,48–50]”
BackgroundSelf-citationChang, J. Y., Komaki, R., Lu, C., Wen, H. Y., Allen, P. K., Tsao, A., Gillin, M., Mohan, R., & Cox, J. D. (2011) · Cancer · doi:10.1002/cncr.26080 · Cited by 180
Self-citationCarlson, D. J., Stewart, R. D., Semenenko, V. A., & Sandison, G. A. (2008) · Radiation Research · doi:10.1667/rr1046.1 · Cited by 175
Bishop, A. J., Greenfield, B., Mahajan, A., Paulino, A. C., Okcu, M. F., Allen, P. K., Chintagumpala, M., Kahalley, L. S., McAleer, M. F., McGovern, S. L., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.05.051 · Cited by 168
Sio, T. T., Lin, H.-K., Shi, Q., Gunn, G. B., Cleeland, C. S., Lee, J. J., Hernandez, M., Blanchard, P., Thaker, N. G., Phan, J., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2016.02.044 · Cited by 166
Self-citationProton therapy for low‐grade gliomas: Results from a prospective trial
Shih, H. A., Sherman, J. C., Nachtigall, L. B., Colvin, M. K., Fullerton, B. C., Daartz, J., Winrich, B. K., Batchelor, T. T., Thornton, L. T., Mancuso, S. M., et al. (2015) · Cancer · doi:10.1002/cncr.29237 · Cited by 162
The Clinical Potential of Intensity Modulated Proton Therapy
Lomax, A., Pedroni, E. S., Rutz, H. P., et al. (2004) · Zeitschrift für Medizinische Physik · doi:10.1078/0939-3889-00217 · Cited by 151 · cited 1×
“IMPT was first used for patient treatments at the Paul Scherrer Institute beginning in 1996.[17] One-dimensional scanning of proton beamlets of a range of energies to treat one transverse plane at a time was employed.”
MethodSmith, A. R. (2009) · Medical Physics · doi:10.1118/1.3058485 · Cited by 151
Frese, M. C., Yu, V. K., Stewart, R. D., & Carlson, D. J. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.06.1983 · Cited by 147
The Quest for Evidence for Proton Therapy: Model-Based Approach and Precision Medicine
Widder, J., van der Schaaf, A., Lambin, P., Marijnen, C. A. M., Pignol, J., Rasch, C. R. N., Slotman, B. J., Verheij, M., & Langendijk, J. A. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.10.004 · Cited by 145
Brown, P. D., Chung, C. D., Liu, D. D., McAvoy, S., Grosshans, D. R., Feghali, K. A. A., Mahajan, A., Li, J., McGovern, S. L., McAleer, M. F., et al. (2021) · Neuro-Oncology · doi:10.1093/neuonc/noab040 · Cited by 116 · cited 1×
“Similar trials are also needed for cognitive preservation in patients with lower-grade gliomas, who have longer survival time.[46] In fact,”
ResultFredriksson, A. (2012) · Medical Physics · doi:10.1118/1.4737113 · Cited by 111
Liu, Q., Ghosh, P., Magpayo, N., Testa, M., Tang, S., Gheorghiu, L., Biggs, P. J., Paganetti, H., Efstathiou, J. A., Lu, H., et al. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.12.046 · Cited by 110
PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization
Liu, W., Frank, S. J., Li, X., Li, Y., Zhu, R. X., & Mohan, R. (2013) · Medical Physics · doi:10.1118/1.4774363 · Cited by 109
Self-citationNational Protocol for Model-Based Selection for Proton Therapy in Head and Neck Cancer
Langendijk, J. A., Hoebers, F. J. P., de Jong, M. A., Doornaert, P., Terhaard, C. H. J., Steenbakkers, R. J. H. M., Hamming‐Vrieze, O., van de Kamer, J. B., Verbakel, W. F. A. R., Keskin-Cambay, F., et al. (2021) · International Journal of Particle Therapy · doi:10.14338/ijpt-20-00089.1 · Cited by 95
Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview
Mohan, R., Das, I. J., & Ling, C. C. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.05.005 · Cited by 84
Self-citationLiu, J., Zhao, Q., Deng, W., Lu, J., Xu, X., Wang, R., Li, X., & Yue, J. (2017) · Radiation Oncology · doi:10.1186/s13014-017-0824-x · Cited by 80
Palma, G., Monti, S., Xu, T., Scifoni, E., Yang, P., Hahn, S. M., Durante, M., Mohan, R., Liao, Z. X., & Cella, L. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.02.039 · Cited by 60
Self-citationXie, X., Lin, S. H., Welsh, J. W., Wei, X., Jin, H., Mohan, R., Liao, Z. X., & Xu, T. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.002 · Cited by 58
Self-citationFitzek, M. M., Thornton, A. F., Harsh, G. R., et al. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01589-9 · Cited by 56 · cited 1×
“tial results suggest high rates of tumor control with acceptable toxicity rates.[43,44] An important study by Shih et al.”
BackgroundBoersma, L. J., Sattler, M. G. A., Maduro, J. H., Bijker, N., Essers, M., van Gestel, C. M. J., Klaver, Y. L. B., Petoukhova, A., Rodrigues, M. F., Russell, N. S., et al. (2022) · Clinical Oncology · doi:10.1016/j.clon.2021.12.007 · Cited by 47
Tucker, S. L., Xu, T., Paganetti, H., Deist, T. M., Verma, V., Choi, N. C., Mohan, R., & Liao, Z. X. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.09.029 · Cited by 36
Self-citationGrassberger, C., Hong, T. S., Hato, T., Yeap, B. Y., Wo, J. Y.-L., Tracy, M., Bortfeld, T. R., Wolfgang, J. A., Eyler, C. E., Goyal, L., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.04.026 · Cited by 35
Palma, G., Monti, S., Conson, M., Xu, T., Hahn, S. M., Durante, M., Mohan, R., Liao, Z. X., & Cella, L. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.00344 · Cited by 35
Self-citationXu, T., Meng, Q. H., Gilchrist, S. C., Lin, S. H., Lin, R., Xu, T., Milgrom, S. A., Gandhi, S. J., Wu, H., Zhao, Y., et al. (2021) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2021.07.035 · Cited by 33
Self-citationThaker, N. G., Frank, S. J., & Feeley, T. W. (2015) · Journal of Comparative Effectiveness Research · doi:10.2217/cer.15.32 · Cited by 27
Brodin, N. P., Kabarriti, R., Schechter, C. B., Pankuch, M., Gondi, V., Kalnicki, S., Garg, M. K., & Tomé, W. A. (2021) · Radiation Oncology · doi:10.1186/s13014-021-01745-1 · Cited by 17
Huang, D., Frank, S. J., Verma, V., Thaker, N. G., Brooks, E. D., Palmer, M. B., Harrison, R. F., Deshmukh, A. A., & Ning, M. S. (2021) · International Journal of Particle Therapy · doi:10.14338/ijpt-20-00058.1 · Cited by 14
Minimax optimization for handling range and setup uncertainties in proton therapy
Fredriksson, A., Forsgren, A. L., & Hårdemark, B. (2011) · Medical Physics · doi:10.1118/1.3556559
Cited by
Enhancing Proton Therapy Efficacy Through Nanoparticle-Mediated Radiosensitization
Ma, J., Shen, H., & Mi, Z. (2024) · Cells · doi:10.3390/cells13221841 · Cited by 23
Metadata
- Authors
- Mohan, R.
- Venue
- Precision Radiation Oncology
- Publisher
- Wiley
- Published
- 2022-04-27
- Volume
- 6
- Issue
- 2
- Pages
- 164-176
- ISSN
- 2398-7324 (ISSN-L)
- OpenAlex
- W4293021298
- Cited by
- 248
- References
- 55
- FWCI
- 25.65
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.