A rapid sample preparation method for mass spectrometric characterization of N‐linked glycans
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A rapid method for analysis of glycans of glycoproteins is presented. This method comprised deglycosylation, sample cleanup and matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) analysis of glycans. The enzymatic deglycosylation of N‐linked glycoproteins was enhanced in terms of speed and reproducibility using an enzyme‐friendly surfactant. The released glycans were desalted using a micro‐scale solid phase extraction (SPE) device packed with a hydrophilic interaction chromatography (HILIC) sorbent. Hydrophilic glycans were well retained by SPE, while salts and surfactants were removed from the sample. The glycans were eluted using 25–50 µL of solvent and analyzed directly without derivatization using MALDI‐MS. MALDI quadrupole time‐of‐flight (Q‐Tof) instrumentation was utilized for glycan profiling and structure characterization by tandem mass spectrometry (MS/MS). The presented method allows sensitive analysis of glycans benefiting from optimized deglycosylation reactions and efficient sample cleanup. Copyright © 2005 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yu, Y.-Q., Gilar, M., Lee, P. J., Bouvier, E. S. P., & Gebler, J. C. (2003) · Analytical Chemistry · doi:10.1021/ac0346196 · Cited by 313
Self-citation
Cited by
Hydrophilic interaction chromatography
Hemström, P., & Irgum, K. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600199 · Cited by 1,176
Glycan labeling strategies and their use in identification and quantification
Ruhaak, L. R., Zauner, G., Huhn, C., Bruggink, C., Deelder, A. M., & Wuhrer, M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3532-z · Cited by 479
HPLC-based analysis of serum N-glycans on a 96-well plate platform with dedicated database software
Royle, L., Campbell, M. P., Radcliffe, C. M., White, D. M., Harvey, D. J., Abrahams, J. L., Kim, Y.-G., Henry, G. W., Shadick, N. A., Weinblatt, M. E., et al. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2007.12.012 · Cited by 466
Advantages of application of UPLC in pharmaceutical analysis
Nováková, L., Matysová, L., & Solich, P. (2006) · Talanta · doi:10.1016/j.talanta.2005.06.035 · Cited by 463
Mass spectrometry for structural characterization of therapeutic antibodies
Zhang, Z., Pan, H., & Chen, X. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20190 · Cited by 316
Metadata
- Authors
- Yu, Y. Q., Gilar, M., Kaska, J., & Gebler, J. C.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2005-07-25
- Volume
- 19
- Issue
- 16
- Pages
- 2331-2336
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2124626375
- Cited by
- 96
- References
- 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.