Automated assignment of high‐resolution collisionally activated dissociation mass spectra using a systematic bond disconnection approach
The DOI matches its Crossref record.
Abstract
An essential component of the process of characterising chemical unknowns via mass spectrometry is the analysis of collisionally activated dissociation (CAD) mass spectra. Existing tools for the automated assignment of CAD spectra typically use a rule‐based approach which identifies those bonds that are likely to break. While valuable, the failure of explicitly rule‐based approaches to suggest rationalisations for a significant proportion of observed product ions led us to develop an alternative approach (elucidation of product ion connectivity, EPIC) based on high‐resolution mass spectrometry, systematic bond disconnection of the precursor structure, and ranking of the resulting substructures. We exemplify this approach with a reanalysis of published MS/MS data for two compounds taken from the literature. Copyright © 2005 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Searching molecular structure databases with tandem mass spectra using CSI:FingerID
Dührkop, K., Shen, H., Meusel, M., Rousu, J., & Böcker, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509788112 · Cited by 1,190
“For the general case, several strategies have been proposed during recent years, including simulation of mass spectra from molecular structure (10, 11), combinatorial fragmentation (12 – 17), and prediction of molecular fingerprints (18, 19).”
BackgroundSchymanski, E. L., Singer, H. P., Slobodnik, J., Ipolyi, I. M., Oswald, P., Krauss, M., Schulze, T., Haglund, P., Letzel, T., Grosse, S., et al. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8681-7 · Cited by 703
In silico fragmentation for computer assisted identification of metabolite mass spectra
Wolf, S., Schmidt, S., Müller-Hannemann, M., & Neumann, S. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-148 · Cited by 698
Mass appeal: metabolite identification in mass spectrometry-focused untargeted metabolomics
Dunn, W. B., Erban, A., Weber, R. J. M., Creek, D. J., Brown, M., Breitling, R., Hankemeier, T., Goodacre, R., Neumann, S., Kopka, J., et al. (2013) · Metabolomics · doi:10.1007/s11306-012-0434-4 · Cited by 555
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Competitive fragmentation modeling of ESI-MS/MS spectra for putative metabolite identification
Allen, F., Greiner, R., & Wishart, D. (2015) · Metabolomics · doi:10.1007/s11306-014-0676-4 · Cited by 398
Dereplication of microbial metabolites through database search of mass spectra
Mohimani, H., Gurevich, A., Shlemov, A., Mikheenko, A., Korobeynikov, A., Cao, L., Shcherbin, E., Nothias, L.-F., Dorrestein, P. C., & Pevzner, P. A. (2018) · Nature Communications · doi:10.1038/s41467-018-06082-8 · Cited by 352
Chemometric methods in data processing of mass spectrometry-based metabolomics: A review
Yi, L., Dong, N., Yun, Y., Deng, B., Ren, D., Liu, S., & Liang, Y. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.02.001 · Cited by 305
Computational mass spectrometry for metabolomics: Identification of metabolites and small molecules
Neumann, S., & Böcker, S. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4142-5 · Cited by 175
“A member of this class is the EPIC tool [41].”
MethodComputational mass spectrometry for small molecules
Scheubert, K., Hufsky, F., & Böcker, S. (2013) · Journal of Cheminformatics · doi:10.1186/1758-2946-5-12 · Cited by 173
“EPIC (elucidation of product ion connectivity) [201] was the first software using systematic bond disconnection and ranking of the resulting substructures.”
BackgroundMethodIdentification of “Known Unknowns” Utilizing Accurate Mass Data and ChemSpider
Little, J. L., Williams, A. J., Pshenichnov, A., & Tkachenko, V. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0265-y · Cited by 168
Allen, F., Pon, A., Greiner, R., & Wishart, D. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01622 · Cited by 160
Structural elucidation of low abundant metabolites in complex sample matrices
van der Hooft, J. J. J., de Vos, R. C. H., Ridder, L., Vervoort, J., & Bino, R. J. (2013) · Metabolomics · doi:10.1007/s11306-013-0519-8 · Cited by 46
“Another approach, which can be applied in the absence of reference libraries, is to match in silico generated substructures of candidate molecules with observed fragment ions (Wolf et al. 2010; Heinonen et al. 2008; Hill and Mortishire-Smith 2005).”
Metadata
- Authors
- Hill, A. W., & Mortishire‐Smith, R. J.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2005-10-03
- Volume
- 19
- Issue
- 21
- Pages
- 3111-3118
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2145651065
- Cited by
- 129
- References
- 0
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.