Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 418

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Effects of chemical lipid extraction and arithmetic lipid correction on stable isotope ratios of fish tissues

Sweeting, C. J., Polunin, N. V. C., Jennings, S.·2006·Rapid Communications in Mass Spectrometry

Abstract

For accurate interpretation of fish trophodynamics from carbon stable isotope data it is necessary to extract tissue lipids. This is because lipid content varies within and among tissues in both space and time, and because lipids are 13 C‐depleted relative to proteins. However, lipid extraction may affect δ 15 N, thus requiring costly and time‐consuming separation of δ 13 C and δ 15 N analyses. These problems have prompted the development of arithmetic correction techniques for δ 13 C, but the techniques and their underlying assumptions have not been systematically tested. This study compared the effects of lipid extraction and arithmetic correction techniques on δ 13 C and δ 15 N of European sea bass ( Dicentrarchus labrax ) tissues. Following Folch lipid extraction from muscle and liver, there was a mean increase in δ 15 N of 0.77‰, but enrichment varied with lipid content such that effects on δ 15 N were hard to predict. Changes in δ 13 C and C:N between untreated and lipid‐extracted samples reflected the quantity of lipid removed. The arithmetic correction techniques of mass balance and lipid correction were sensitive to the C:N of the lipid‐extracted tissue and to the assumed depletion of lipid δ 13 C relative to protein δ 13 C. However, the mass balance approach was appropriate for the mathematical correction of bulk tissue data in most circumstances, provided that the C:N of lipid‐extracted tissue could be determined for a small proportion of samples. Application of mass balance arithmetic correction can lead to significant time and cost savings in trophodynamic studies, because the majority of δ 13 C and δ 15 N analyses would not need to be run separately. Copyright © 2006 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.2347

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 418

Metadata

Authors
Sweeting, C. J., Polunin, N. V. C., & Jennings, S.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2006-01-23
Volume
20
Issue
4
Pages
595-601
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W1996873258
Cited by
418
References
29
FWCI
15.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of chemical lipid extraction and arithmetic lipid correction on stable isotope ratios of fish tissues. https://app.cochat.ai/papers/10.1002/rcm.2347
The paper
Sweeting, C. J., Polunin, N. V. C., & Jennings, S. (2006). Effects of chemical lipid extraction and arithmetic lipid correction on stable isotope ratios of fish tissues. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2347

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.