The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Normalization of measured stable isotopic compositions to isotope reference scales – a review
Abstract
In stable isotope ratio mass spectrometry (IRMS), the stable isotopic composition of samples is measured relative to the isotopic composition of a working gas. This measured isotopic composition must be converted and reported on the respective international stable isotope reference scale for the accurate interlaboratory comparison of results. This data conversion procedure, commonly called normalization, is the first set of calculations done by the users. In this paper, we present a discussion and mathematical formulation of several existing routinely used normalization procedures. These conversion procedures include: single‐point anchoring (versus working gas and certified reference standard), modified single‐point normalization, linear shift between the measured and the true isotopic composition of two certified reference standards, two‐point and multi‐point linear normalization methods. Mathematically, the modified single‐point, two‐point, and multi‐point normalization methods are essentially the same. By utilizing laboratory analytical data, the accuracy of the various normalization methods (given by the difference between the true and the normalized isotopic composition) has been compared. Our computations suggest that single‐point anchoring produces normalization errors that exceed the maximum total uncertainties (e.g. 0.1‰ for δ 13 C) often reported in the literature, and, therefore, that it must not be used for routinely anchoring stable isotope measurement results to the appropriate international scales. However, any normalization method using two or more certified reference standards produces a smaller normalization error provided that the isotopic composition of the standards brackets the isotopic composition of unknown samples. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Craig, H. (1957) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(57)90024-8 · Cited by 4,170
(1973) · Earth-Science Reviews · doi:10.1016/0012-8252(73)90028-7 · Cited by 3,317
Petry, F. E. (1997) · Kluwer Academic Publishers eBooks · Cited by 2,303
Isotopes: Principles and Applications
Faure, G., & Mensing, T. M. (2004) · Cited by 1,148
Standards for stable isotope measurements in natural compounds
GONFIANTINI, R. (1978) · Nature · doi:10.1038/271534a0 · Cited by 1,081
Referencing strategies and techniques in stable isotope ratio analysis
Werner, R. A., & Brand, W. A. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.258 · Cited by 1,033
Hoefs, J. (1997) · Springer eBooks · doi:10.1007/978-3-662-03377-7 · Cited by 1,009
New Guidelines for δ 13 C Measurements
Coplen, T. B., Brand, W. A., Gehre, M., Gröning, M., Meijer, H. A. J., Toman, B., & Verkouteren, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac052027c · Cited by 906
Principles of stable isotope geochemistry
(2007) · Choice Reviews Online · doi:10.5860/choice.44-6251 · Cited by 905
New guidelines for reporting stable hydrogen, carbon, and oxygen isotope-ratio data
Coplen, T. B. (1996) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(96)00263-3 · Cited by 862
Nelson, S. T. (2000) · Rapid Communications in Mass Spectrometry · Cited by 146
Estimation of a Common Mean and Weighted Means Statistics
Rukhin, A. L., & Vangel, M. G. (1998) · Journal of the American Statistical Association · doi:10.1080/01621459.1998.10474111 · Cited by 115
Paul, D., & Skrzypek, G. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.11.006 · Cited by 92
Self-citationSkrzypek, G., & Paul, D. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2688 · Cited by 69
Self-citationIsotopic fractionation between gaseous and condensed carbon dioxide
Grootes, P. M., Mook, W. G., & Vogel, J. C. (1969) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01392177 · Cited by 45
Verkouteren, R. M. (1999) · Analytical Chemistry · doi:10.1021/ac990233c · Cited by 32
web-based interactive data processing: application to stable isotope metrology
Verkouteren, R. M., & Lee, J. N. (2001) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160100870 · Cited by 17
Strategies and Practicalities in the Production and Use of Gas Isotope Standard Materials
Verkouteren, R. M. (2004) · Elsevier eBooks · doi:10.1016/b978-044451114-0/50045-4 · Cited by 5
Cited by
Soil networks become more connected and take up more carbon as nature restoration progresses
Morriën, E., Hannula, S. E., Snoek, L. B., Helmsing, N. R., Zweers, H., de Hollander, M., Soto, R. L., Bouffaud, M.-L., Buée, M., Dimmers, W., et al. (2017) · Nature Communications · doi:10.1038/ncomms14349 · Cited by 936
Elsner, M., Jochmann, M. A., Hofstetter, T. B., Hunkeler, D., Bernstein, A., Schmidt, T. C., & Schimmelmann, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5683-y · Cited by 276
Best practices for calibrating and reporting stable isotope measurements in archaeology
Szpak, P., Metcalfe, J. Z., & Macdonald, R. A. (2017) · Journal of Archaeological Science: Reports · doi:10.1016/j.jasrep.2017.05.007 · Cited by 272
Corals record long-term Leeuwin current variability including Ningaloo Niño/Niña since 1795
Zinke, J., Rountrey, A., Feng, M., Xie, S.-P., Dissard, D., Rankenburg, K., Lough, J. M., & McCulloch, M. T. (2014) · Nature Communications · doi:10.1038/ncomms4607 · Cited by 111
Ensuring the reliability of stable isotope ratio data—beyond the principle of identical treatment
Carter, J. F., & Fry, B. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6551-0 · Cited by 71
Metadata
- Authors
- Paul, D., Skrzypek, G., & Fórizs, I.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2007-08-17
- Volume
- 21
- Issue
- 18
- Pages
- 3006-3014
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2147373467
- Cited by
- 536
- References
- 18
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.