Detection of 20‐hydroxyecdysone in calf urine by comparative liquid chromatography/high‐resolution mass spectrometry and liquid chromatography/tandem mass spectrometry measurements: application to the control of the potential misuse of ecdysteroids in cattle
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Ecdysteroids, which are steroid hormones in invertebrates, but which are also present in plants, could potentially be used as anabolic agents in food‐producing animals. The control of ecdysteroid misuse in cattle relies on the development of an efficient method for their detection in biological matrices at trace levels (µg L −1 ). In order to propose an analytical procedure dedicated to the identification of excreted 20‐hydroxyecdysone (20E) in urine and faecal samples of breeding animals, a comparative study of the spectrometric behaviour of these compounds was carried out both by LC/(ESI‐)/HRMS n (hybrid linear ion trap – orbital trap) and by LC/(ESI+)/MS/MS (triple quadrupole). This study revealed the formation of a large number of product ions both in positive and negative ion mode, corresponding to losses of water molecules and specific cleavages on the side chain. The sample preparation consisted of sequential purification on two solid‐phase extraction cartridges (SPE octadecylsilyl and SPE silica). The detection limits were around 0.5 µg L −1 in the selected reaction monitoring (SRM) mode and recoveries above 60% were obtained. The method was successfully applied to the analysis of real samples collected from calves treated with 60 mg 20E over 4 days. Analysis of the samples allowed the investigation of the kinetics of elimination of 20E in calf urine and determination of the time‐frame for the control of potential abuse. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chromatographic procedures for phytoecdysteroids
Lafont, R., Morgan, E. D., & Wilson, I. D. (1994) · Journal of Chromatography A · doi:10.1016/0021-9673(94)85205-7 · Cited by 46
Self-citationEcdysteroids: one potential new anabolic family in breeding animals
Le Bizec, B., Antignac, J.-P., Monteau, F., & Andre, F. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)00874-7 · Cited by 41
Self-citationStudy of excretion of ecdysterone in human urine
Tsitsimpikou, C., Tsamis, G. D., Siskos, P. A., Spyridaki, M. E., & Georgakopoulos, C. G. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.433 · Cited by 33
Destrez, B., Pinel, G., Monteau, F., Lafont, R., & Le Bizec, B. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.10.015 · Cited by 33
Self-citation
Cited by
Kumpun, S., Girault, J.-P., Dinan, L., Blais, C., Maria, A., Dauphin-Villemant, C., Yingyongnarongkul, B., Suksamrarn, A., & Lafont, R. (2011) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2011.03.016 · Cited by 45
Self-citationDestrez, B., Pinel, G., Monteau, F., Lafont, R., & Le Bizec, B. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.10.015 · Cited by 33
Self-citationEcdysteroid metabolism in mammals: The fate of ingested 20-hydroxyecdysone in mice and rats
Dinan, L., Balducci, C., Guibout, L., Foucault, A.-S., Bakrim, A., Kumpun, S., Girault, J.-P., Tourette, C., Dioh, W., Dilda, P. J., et al. (2021) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2021.105896 · Cited by 23
Self-citationEfficient Extraction and Sensitive HPLC-MS/MS Quantification of Selected Ecdysteroids in Plants
Fang, X., Szołtysik, R., Tang, J., & Bajkacz, S. (2022) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2022.104580 · Cited by 20
Ambrosio, G., Yuliandra, T., Wuest, B., Mazzarino, M., Torre, X. D. L., Botrè, F., Diel, P., Isenmann, E., & Parr, M. K. (2021) · doi:10.20944/preprints202105.0106.v1 · Cited by 14
“…of 14-deoxy-ecdysterone after administration of ecdys-terone was previously reported by Brant and Parr et al. in humans [33,34], Kumpun in mice [10], and Destrez in calves [43,44]. was previously reported by Brant and Parr et al. in humans [33,34], Kumpun mice [10], and Destrez in calves [43,44].”
Background
Metadata
- Authors
- Destrez, B., Pinel, G., Bichon, E., Monteau, F., Lafont, R., & Le Bizec, B.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2008-11-17
- Volume
- 22
- Issue
- 24
- Pages
- 4073-4080
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2108935617
- Cited by
- 20
- References
- 4
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of 20‐hydroxyecdysone in calf urine by comparative liquid chromatography/high‐resolution mass spectrometry and liquid chromatography/tandem mass spectrometry measurements: application to the control of the potential misuse of ecdysteroids in cattle. https://app.cochat.ai/papers/10.1002/rcm.3816
- The paper
- Destrez, B., Pinel, G., Bichon, E., Monteau, F., Lafont, R., & Le Bizec, B. (2008). Detection of 20‐hydroxyecdysone in calf urine by comparative liquid chromatography/high‐resolution mass spectrometry and liquid chromatography/tandem mass spectrometry measurements: application to the control of the potential misuse of ecdysteroids in cattle. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.3816
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.