Cited by 46Chromatography in Natural ProductsPhytochemical Studies and BioactivitiesAnalytical Chemistry and Chromatography

Chromatographic procedures for phytoecdysteroids

Lafont, R., Morgan, E.D., Wilson, I.D.·1994·Journal of Chromatography A

Integrity signals

Registry

Crossref · 10.1016/0021-9673(94)85205-7

Cites

78 of 78 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • SFC is compatible with UV/vis-, FT-IR and MS-detection.

    “SFC is compatible with UV/vis-, FT-IRand MS-detection [107,117,129].”

    From Ecdysteroids (2021) · cites this paper as [107]

  • Open-column chromatography used to be the standard workhorse for laboratory purification of ecdysteroids but has gradually been replaced by flash chromatography and preparative HPLC.

    “Open-column chromatography on silica or alumina eluted with solvents of increasing percentages of methanol or ethanol in hexane, dichloromethane or chloroform used to be the standard 'workhorse' for the laboratory purification of ecdysteroids, as it was of other plant secondary compounds, but this has gradually been replaced by flash chromatography and preparative HPLC on NP-and RP-stationary”

    From Ecdysteroids (2021) · cites this paper as [107]

  • SFC separation of ecdysteroids provides shorter retention times, sharper peaks and greater sensitivity than HPLC.

    “SFC separation of ecdysteroids, using critical CO 2 , which is non-polar, modified with methanol and silica/bonded (NP) silica HPLC columns or fused silica capillary columns, provides shorter retention times, sharper peaks and greater sensitivity than HPLC.”

    From Ecdysteroids (2021) · cites this paper as [107]

  • The most commonly used HPLC systems are variants on a C18-RP-column eluted with a linear gradient of methanol or acetonitrile in water.

    “The most commonly used HPLC systems are variants on a C 18 -RP-column eluted with a linear gradient of methanol or acetonitrile in water.”

    From Ecdysteroids (2021) · cites this paper as [107]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lafont, R., Morgan, E. D., & Wilson, I. D.
Affiliations
  • Centre National de la Recherche Scientifique (FR)
  • Keele University (GB)
Corresponding author
Morgan, E.D.
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
1994-01
Volume
658
Issue
1
Pages
31-53
ISSN
0021-9673 (ISSN-L)
OpenAlex
W1981361344
Cited by
46
References
78
Citations by year
2024: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2013: 2
FWCI
4.41
Type
journal article
Language
en
Open access
closed
Locations
Journal of Chromatography A (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Chromatography in Natural Products
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Phytochemical Studies and Bioactivities
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
Keywords
phytoecdysteroids, ecdysteroids, plant steroids, separation processes, chromatographic methods

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review