CoChat

A new method to determine the 17 O isotopic abundance in CO 2 using oxygen isotope exchange with a solid oxide

Assonov, S.S., Brenninkmeijer, C. A. M. · 2001 · Rapid Communications in Mass Spectrometry
Cited by 51

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This paper discusses a simple method to determine 17 O isotope excess or deficiency (‘mass‐independent isotopic composition’) in CO 2 gas. When applying conventional mass spectrometry of CO 2 ( m/z 44, 45 and 46) to determine the 17 O/ 16 O ratio, the 13 C/ 12 C ratio has to be established separately. This can be achieved by analysing an aliquot of sample CO 2 before and after subjecting it to oxygen isotope exchange with a pool of oxygen with ‘normal’ 17 O/ 16 O ratio, i.e. with Δ 17 O≡δ 17 O−0.516 × δ 18 O = 0. Cerium oxide has been shown to be practically well suited for the exchange of CO 2 oxygen; the reagent is safe and does not produce any contamination. The CO 2 ‐CeO 2 exchange reaction has 99.8 ± 0.7% recovery yield. At 650 °C this reaction reaches equilibrium in 30 min and, as tested, results in complete oxygen replacement. Δ 17 O determinations depend on accuracy of CO 2 delta measurements: the repeatability of ±0.015‰ (1σ) in δ 45 R and δ 46 R deter‐mination relative to the working reference results in an error of Δ 17 O as small as ±0.33‰. Such a precision is sufficient for Δ 17 O determination in stratospheric CO 2 . The calculated Δ 17 O value systematically depends on absolute 17 R and 13 R ratios in isotopic reference materials, which are presently not yet known with certainty (the 17 R value is most important), and may be inadequate for 17 O‐correction with a = 0.516. Within the present uncertainty, Δ 17 O determined in 17 O‐enriched CO 2 agrees with the value directly measured in the enriched O 2 from which this CO 2 was produced. Besides Δ 17 O determination, investigated CO 2 ‐CeO 2 equilibration may have several other implications. Fast, complete isotopic exchange of CO 2 by reaction with CeO 2 may also be employed to get reproducible 17 O‐correction and, hence, to better monitor small δ 13 C shifts and to isotopically equilibrate mixtures of CO 2 gases. Copyright © 2001 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.529

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 51

Metadata

Authors
Assonov, S. S., & Brenninkmeijer, C. A. M.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2001-11-20
Volume
15
Issue
24
Pages
2426-2437
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2083564275
Cited by
51
References
3
FWCI
2.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.