High‐precision measurements of 17 O/ 16 O and 18 O/ 16 O ratios in CO 2
Abstract
RATIONALE: Measurements of δ 17 O and δ 18 O values of tropospheric CO 2 are of great importance. However, to be useful, such measurements must be an order of magnitude more precise than in current published literature. With this purpose we developed a new method for high‐precision mass spectrometric measurements of 17 O/ 16 O and 18 O/ 16 O ratios in CO 2 , which is presented in this study. METHODS: The method is based on isotopic exchange equilibration between H 2 O and CO 2 in sealed glass ampoules followed by water fluorination to produce O 2 . Dual inlet isotope ratio mass spectrometric (IRMS) measurements of the δ 17 O and δ 18 O values of this O 2 allow δ 17 O values of CO 2 to be obtained with very high precision (0.01 to 0.03 ‰). This method requires about 70 µmol of CO 2 . RESULTS: Measurements of standard CO 2 gas and atmospheric CO 2 yield reproducibility of 0.01 to 0.03 ‰ for both δ 17 O and δ 18 O values, and 5 per meg for 17 O excess . Fractionation factors 17 α and 18 α were determined in the H 2 O–CO 2 equilibrium at 25 °C as 1.021254 ± 0.00004 and 1.041036 ± 0.00008, respectively, and the ratio ln 17 α/ln 18 α as 0.5229 ± 0.0001. CONCLUSIONS: The results demonstrate that the new method is the most accurate analytical procedure ever presented for measurements of 17 O excess of CO 2 gas. It is suitable for measurements of CO 2 extracted from relatively small samples of air (~5 L), and is thus useful for monitoring the 17 O excess of CO 2 on a broad global scale. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brand, W. A., Assonov, S. S., & Coplen, T. B. (2010) · Pure and Applied Chemistry · doi:10.1351/pac-rep-09-01-05 · Cited by 385
Equilibrium mass-dependent fractionation relationships for triple oxygen isotopes
Cao, X., & Liu, Y. (2011) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2011.09.048 · Cited by 152
Oxygen isotope fractionation in stratospheric CO2
Thiemens, M. H., Jackson, T., Mauersberger, K., Schueler, B., & Morton, J. (1991) · Geophysical Research Letters · doi:10.1029/91gl00121 · Cited by 113
Research works printed but not linked: 30
- 10.1029/94GL02996 · DOI
- 10.1029/2001GL014343 · DOI
- 10.1029/2003GL018451 · DOI
- 10.1029/2004GL021011 · DOI
- 10.1016/j.gca.2010.08.016 · DOI · Paper page
- Bhattacharya S. K., 1989, New evidence for symmetry dependent isotope effects: O + CO reaction, Z. Naturforsch., 44, 435, 10.1515/zna-1989-0513 · DOI
- 10.1002/(SICI)1097-0231(19980430)12:8<479::AID-RCM184>3.0.CO;2-R · doi:10.1002/(sici)1097-0231(19980430)12:8<479::aid-rcm184>3.0.co;2-r
- 10.1002/rcm.529 · DOI
- 10.1021/ac050266u · DOI
- 10.1021/ac902731m · DOI
- 10.1002/rcm.1267 · DOI
- 10.1002/rcm.2250 · DOI · Paper page
- 10.1021/ac50052a038 · DOI
- 10.1016/0016-7037(53)90051-9 · DOI · Paper page
- Stumm W., 1996, Aquatic Chemistry: Chemical Equilibria and Rates in Natural Waters
- 10.1002/rcm.5125 · DOI
- Gonfiantini R., 1995, Reference and Intercomparison Materials for Stable Isotopes of Light Elements, 13
- 10.1002/rcm.1011 · DOI
- 10.1002/rcm.1560 · DOI
- 10.1002/rcm.2516 · doi:10.1002/rcm.2516
- 10.1021/ac9602938 · DOI
- Brenninkmeijer C. A. M., 1983, Oxygen isotope fractionation between CO2 and H2O, Isot. Geosci., 1, 181
- 10.1016/j.epsl.2011.12.026 · DOI
- 10.1016/0012-821X(76)90115-1 · DOI · Paper page
- Mook W. G., 2000, Enviromental Isotopes in the Hydrological Cycle: Introduction, 107
- 10.1016/S0016-7037(02)00832-3 · DOI · Paper page
- 10.1016/j.gca.2004.09.001 · DOI · Paper page
- 10.1021/ac960208w · doi:10.1021/ac960208w
- 10.5194/acp-11-1473-2011 · DOI
- 10.1016/j.gca.2006.06.1545 · DOI · Paper page
Cited by
Atmospheric composition change – global and regional air quality
Monks, P. S., Granier, C., Fuzzi, S., Stohl, A., Williams, M. L., Akimoto, H., Amann, M., Baklanov, A., Baltensperger, U., Bey, I., et al. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.08.021 · Cited by 872
Stable isotopes in atmospheric water vapor and applications to the hydrologic cycle
Galewsky, J., Steen‐Larsen, H. C., Field, R. D., Worden, J., Risi, C., & Schneider, M. (2016) · Reviews of Geophysics · doi:10.1002/2015rg000512 · Cited by 489
Absolute isotopic abundance ratios and the accuracy of Δ47 measurements
Daëron, M., Blamart, D., Peral, M., & Affek, H. P. (2016) · Chemical Geology · doi:10.1016/j.chemgeo.2016.08.014 · Cited by 310
Stable isotope deltas: tiny, yet robust signatures in nature
Brand, W. A., & Coplen, T. B. (2012) · Isotopes in Environmental and Health Studies · doi:10.1080/10256016.2012.666977 · Cited by 283
Guo, W., Mosenfelder, J. L., Goddard, W. A., & Eiler, J. M. (2009) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2009.05.071 · Cited by 262
Metadata
- Authors
- Barkan, E., & Luz, B.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2012-10-16
- Volume
- 26
- Issue
- 23
- Pages
- 2733-2738
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2146456441
- Cited by
- 247
- References
- 3
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐precision measurements of 17 O/ 16 O and 18 O/ 16 O ratios in CO 2. https://app.cochat.ai/papers/10.1002/rcm.6400
- The paper
- Barkan, E., & Luz, B. (2012). High‐precision measurements of 17 O/ 16 O and 18 O/ 16 O ratios in CO 2. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.6400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.