A closed testing procedure to select an appropriate method for updating prediction models
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Prediction models fitted with logistic regression often show poor performance when applied in populations other than the development population. Model updating may improve predictions. Previously suggested methods vary in their extensiveness of updating the model. We aim to define a strategy in selecting an appropriate update method that considers the balance between the amount of evidence for updating in the new patient sample and the danger of overfitting. We consider recalibration in the large (re‐estimation of model intercept); recalibration (re‐estimation of intercept and slope) and model revision (re‐estimation of all coefficients) as update methods. We propose a closed testing procedure that allows the extensiveness of the updating to increase progressively from a minimum (the original model) to a maximum (a completely revised model). The procedure involves multiple testing with maintaining approximately the chosen type I error rate. We illustrate this approach with three clinical examples: patients with prostate cancer, traumatic brain injury and children presenting with fever. The need for updating the prostate cancer model was completely driven by a different model intercept in the update sample (adjustment: 2.58). Separate testing of model revision against the original model showed statistically significant results, but led to overfitting (calibration slope at internal validation = 0.86). The closed testing procedure selected recalibration in the large as update method, without overfitting. The advantage of the closed testing procedure was confirmed by the other two examples. We conclude that the proposed closed testing procedure may be useful in selecting appropriate update methods for previously developed prediction models. Copyright © 2016 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 1×
“Discrimination was assessed with the concordance index (c-index) [14,15].”
MethodA note on a general definition of the coefficient of determination
NAGELKERKE, N. J. D. (1991) · Biometrika · doi:10.1093/biomet/78.3.691 · Cited by 5,927
Evaluating the Yield of Medical Tests
Harrell, F. E. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320430047030 · Cited by 3,490 · cited 1×
“Discrimination was assessed with the concordance index ( c -index) [14,15].”
Internal validation of predictive models
Steyerberg, E. W., Harrell, F. E., Borsboom, G. J. J. M., Eijkemans, M. J. C., Vergouwe, Y., & Habbema, J. D. F. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00341-9 · Cited by 2,746
Self-citationAssessing the Generalizability of Prognostic Information
Justice, A. C., Covinsky, K. E., & Berlin, J. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00016 · Cited by 1,160
Debray, T. P. A., Vergouwe, Y., Koffijberg, H., Nieboer, D., Steyerberg, E. W., & Moons, K. G. M. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2014.06.018 · Cited by 597 · cited 1×
“As a consequence, evidence on reproducibility of the updated model for the considered populations is relevant [26,27].”
BackgroundSelf-citationTwo Further Applications of a Model for Binary Regression
Cox, D. R. (1958) · Biometrika · doi:10.2307/2333203 · Cited by 557
Two further applications of a model for binary regression
COX, D. R. (1958) · Biometrika · doi:10.1093/biomet/45.3-4.562 · Cited by 556 · cited 2×
“Calibration was assessed with the calibration intercept and slope [4].”
MethodSteyerberg, E. W., Borsboom, G. J. J. M., van Houwelingen, H. C., Eijkemans, M. J. C., & Habbema, J. D. F. (2004) · Statistics in Medicine · doi:10.1002/sim.1844 · Cited by 552 · cited 1×
“Some kind of shrinkage of the regression coefficients should be considered [22].”
BackgroundSelf-citationValidation of probabilistic predictions
Miller, M. E., Langefeld, C. D., Tierney, W. M., Hui, S. L., & McDonald, C. J. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300107 · Cited by 129 · cited 1×
“Data collected in the new populationmay then be used to update themodel to performwell given the new circumstances [21].”
Method
Cited by
Calculating the sample size required for developing a clinical prediction model
Riley, R. D., Ensor, J., Snell, K. I. E., Harrell, F. E., Martin, G. P., Reitsma, J. B., Moons, K. G. M., Collins, G., & van Smeden, M. (2020) · BMJ · doi:10.1136/bmj.m441 · Cited by 2,917
Damen, J. A., Pajouheshnia, R., Heus, P., Moons, K. G. M., Reitsma, J. B., Scholten, R. J. P. M., Hooft, L., & Debray, T. P. A. (2019) · BMC Medicine · doi:10.1186/s12916-019-1340-7 · Cited by 250
“As previously emphasized, more extensive revision methods are often not needed [24, 25, 88].”
BackgroundSelf-citationBinuya, M. A. E., Engelhardt, E. G., Schats, W., Schmidt, M. K., & Steyerberg, E. W. (2022) · BMC Medical Research Methodology · doi:10.1186/s12874-022-01801-8 · Cited by 246
Self-citationDetection of calibration drift in clinical prediction models to inform model updating
Davis, S. E., Greevy, R. A., Lasko, T. A., Walsh, C. G., & Matheny, M. E. (2020) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2020.103611 · Cited by 160
Jenkins, D. A., Martin, G. P., Sperrin, M., Riley, R. D., Debray, T. P. A., Collins, G. S., & Peek, N. (2021) · Diagnostic and Prognostic Research · doi:10.1186/s41512-020-00090-3 · Cited by 131
Self-citationOpen questions and research gaps for monitoring and updating AI-enabled tools in clinical settings
Davis, S. E., Walsh, C. G., & Matheny, M. E. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.958284 · Cited by 33
Levy, T. J., Coppa, K., Cang, J., Barnaby, D. P., Paradis, M. D., Cohen, S. L., Makhnevich, A., van Klaveren, D., Kent, D. M., Davidson, K. W., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-34646-2 · Cited by 14
“Other methods in the literature for correcting model performance calibration drift include a closed test procedure 54 , applying bootstrap resampling while evaluating the updating methods and scoring rules 10 , and dynamically adjusting the window lengths 12 .”
BackgroundMethod
Metadata
- Authors
- Vergouwe, Y., Nieboer, D., Oostenbrink, R., Debray, T. P. A., Murray, G. D., Kattan, M. W., Koffijberg, H., Moons, K. G. M., & Steyerberg, E. W.
- Venue
- Statistics in Medicine
- Publisher
- Wiley
- Published
- 2016-11-28
- Volume
- 36
- Issue
- 28
- Pages
- 4529-4539
- ISSN
- 0277-6715 (ISSN-L)
- 1097-0258
- OpenAlex
- W2557592025
- Cited by
- 155
- References
- 10
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.