The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
High‐Concentration Solvent Exfoliation of Graphene
Open accessAbstract
A method is demonstrated to prepare graphene dispersions at high concentrations, up to 1.2 mg mL−1, with yields of up to 4 wt% monolayers. This process relies on low‐power sonication for long times, up to 460 h. Transmission electron microscopy shows the sonication to reduce the flake size, with flake dimensions scaling as t−1/2. However, the mean flake length remains above 1 µm for all sonication times studied. Raman spectroscopy shows defects are introduced by the sonication process. However, detailed analysis suggests that predominately edge, rather than basal‐plane, defects are introduced. These dispersions are used to prepare high‐quality free‐standing graphene films. The dispersions can be heavily diluted by water without sedimentation or aggregation. This method facilitates graphene processing for a range of applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Geim, A. K., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1849 · Cited by 39,979
Graphene: Status and Prospects
Geim, A. K. (2009) · Science · doi:10.1126/science.1158877 · Cited by 13,942
Superior Thermal Conductivity of Single-Layer Graphene
Balandin, A. A., Ghosh, S., Bao, W., Calizo, I., Teweldebrhan, D., Miao, F., & Lau, C. N. (2008) · Nano Letters · doi:10.1021/nl0731872 · Cited by 13,823
Graphene-based composite materials
Stankovich, S., Dikin, D. A., Dommett, G. H. B., Kohlhaas, K. M., Zimney, E. J., Stach, E. A., Piner, R. D., Nguyen, S. T., & Ruoff, R. S. (2006) · Nature · doi:10.1038/nature04969 · Cited by 12,922
Two-dimensional atomic crystals
Novoselov, K. S., Jiang, D., Schedin, F., Booth, T. J., Khotkevich, V. V., Morozov, S. V., & Geim, A. K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502848102 · Cited by 11,788
Cited by
Carbon materials for chemical capacitive energy storage
Zhai, Y., Dou, Y., Zhao, D., Fulvio, P. F., Mayes, R. T., & Dai, S. (2011) · Advanced Materials · doi:10.1002/adma.201100984 · Cited by 2,964
Georgakilas, V., Perman, J. A., Tucek, J., & Zboril, R. (2015) · Chemical Reviews · doi:10.1021/cr500304f · Cited by 2,147
Grapheneviasonication assisted liquid-phase exfoliation
Ciesielski, A., & Samorì, P. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60217f · Cited by 1,207
Chabot, V., Higgins, D., Yu, A., Xiao, X., Chen, Z., & Zhang, J. (2014) · Energy & Environmental Science · doi:10.1039/c3ee43385d · Cited by 1,119
Sensitive, High-Strain, High-Rate Bodily Motion Sensors Based on Graphene–Rubber Composites
Boland, C. S., Khan, U., Backes, C., O’Neill, A., McCauley, J., Duane, S., Shanker, R., Liu, Y., Jurewicz, I., Dalton, A. B., et al. (2014) · ACS Nano · doi:10.1021/nn503454h · Cited by 793
Self-citation
Metadata
- Authors
- Khan, U., O'Neill, A., Lotya, M., De, S., & Coleman, J. N.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2010-03-26
- Volume
- 6
- Issue
- 7
- Pages
- 864-871
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2056255574
- Cited by
- 1,010
- References
- 6
- FWCI
- 29.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐Concentration Solvent Exfoliation of Graphene. https://app.cochat.ai/papers/10.1002/smll.200902066
- The paper
- Khan, U., O'Neill, A., Lotya, M., De, S., & Coleman, J. N. (2010). High‐Concentration Solvent Exfoliation of Graphene. Small. https://doi.org/10.1002/smll.200902066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.