The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Handwritten, Soft Circuit Boards and Antennas Using Liquid Metal Nanoparticles
Abstract
Soft conductors are created by embedding liquid metal nanoparticles between two elastomeric sheets. Initially, the particles form an electrically insulating composite. Soft circuit boards can be handwritten by a stylus, which sinters the particles into conductive traces by applying localized mechanical pressure to the elastomeric sheets. Antennas with tunable frequencies are formed by sintering nanoparticles in microchannels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
Stretchable, Transparent, Ionic Conductors
Keplinger, C., Sun, J.-Y., Foo, C. C., Rothemund, P., Whitesides, G. M., & Suo, Z. (2013) · Science · doi:10.1126/science.1240228 · Cited by 1,754
A Stretchable Form of Single-Crystal Silicon for High-Performance Electronics on Rubber Substrates
Khang, D.-Y., Jiang, H., Huang, Y., & Rogers, J. A. (2006) · Science · doi:10.1126/science.1121401 · Cited by 1,689
Dickey, M. D., Chiechi, R. C., Larsen, R. J., Weiss, E. A., Weitz, D. A., & Whitesides, G. M. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701216 · Cited by 1,468
Self-citationKo, S. H., Pan, H., Grigoropoulos, C. P., Luscombe, C. K., Fréchet, J. M. J., & Poulikakos, D. (2007) · Nanotechnology · doi:10.1088/0957-4484/18/34/345202 · Cited by 770
Characterization of Nontoxic Liquid-Metal Alloy Galinstan for Applications in Microdevices
Liu, T., Sen, P., & Kim, C.-J. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2174421 · Cited by 719
Pen‐on‐Paper Flexible Electronics
Russo, A., Ahn, B. Y., Adams, J. J., Duoss, E. B., Bernhard, J. T., & Lewis, J. A. (2011) · Advanced Materials · doi:10.1002/adma.201101328 · Cited by 696
Self-citationUltrastretchable Fibers with Metallic Conductivity Using a Liquid Metal Alloy Core
Zhu, S., So, J., Mays, R., Desai, S., Barnes, W. R., Pourdeyhimi, B., & Dickey, M. D. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201202405 · Cited by 638
Self-citationStretchable, Curvilinear Electronics Based on Inorganic Materials
Kim, D., Xiao, J., Song, J., Huang, Y., & Rogers, J. A. (2010) · Advanced Materials · doi:10.1002/adma.200902927 · Cited by 593
Reversibly Deformable and Mechanically Tunable Fluidic Antennas
So, J., Thelen, J., Qusba, A., Hayes, G. J., Lazzi, G., & Dickey, M. D. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200900604 · Cited by 555
Self-citationHyperelastic pressure sensing with a liquid-embedded elastomer
Park, Y.-L., Majidi, C., Kramer, R., Bérard, P., & Wood, R. J. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/12/125029 · Cited by 513
Mechanically Sintered Gallium–Indium Nanoparticles
Boley, J. W., White, E. L., & Kramer, R. K. (2015) · Advanced Materials · doi:10.1002/adma.201404790 · Cited by 439
Self‐Healing Stretchable Wires for Reconfigurable Circuit Wiring and 3D Microfluidics
Palleau, E., Reece, S., Desai, S. C., Smith, M. E., & Dickey, M. D. (2013) · Advanced Materials · doi:10.1002/adma.201203921 · Cited by 432
Self-citationLiquid‐Phase Metal Inclusions for a Conductive Polymer Composite
Fassler, A., & Majidi, C. (2015) · Advanced Materials · doi:10.1002/adma.201405256 · Cited by 409
Cao, Q., Hur, S. ‐., Zhu, Z. ‐., Sun, Y. G., Wang, C. ‐., Meitl, M. A., Shim, M., & Rogers, J. A. (2006) · Advanced Materials · doi:10.1002/adma.200501740 · Cited by 360
Hohman, J. N., Kim, M., Wadsworth, G. A., Bednar, H. R., Jiang, J., LeThai, M. A., & Weiss, P. S. (2011) · Nano Letters · doi:10.1021/nl202728j · Cited by 326
On the resistivity and surface tension of the eutectic alloy of gallium and indium
Zrnic, D., & Swatik, D. S. (1969) · Journal of the Less Common Metals · doi:10.1016/0022-5088(69)90121-0 · Cited by 231
Towards All‐Soft Matter Circuits: Prototypes of Quasi‐Liquid Devices with Memristor Characteristics
Koo, H., So, J., Dickey, M. D., & Velev, O. D. (2011) · Advanced Materials · doi:10.1002/adma.201101257 · Cited by 220
Self-citationSoft-matter capacitors and inductors for hyperelastic strain sensing and stretchable electronics
Fassler, A., & Majidi, C. (2013) · Smart Materials and Structures · doi:10.1088/0964-1726/22/5/055023 · Cited by 198
Soft curvature sensors for joint angle proprioception
Kramer, R. K., Majidi, C., Sahai, R., & Wood, R. J. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094701 · Cited by 174
Thelen, J. L., Dickey, M. D., & Ward, T. (2012) · Lab on a Chip · doi:10.1039/c2lc40492c · Cited by 166
Self-citationHutter, T., Bauer, W. C., Elliott, S. R., & Huck, W. T. S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200324 · Cited by 165
Chiechi, R. C., Weiss, E. A., Dickey, M. D., & Whitesides, G. M. (2007) · Angewandte Chemie · doi:10.1002/ange.200703642 · Cited by 141
Self-citationA frequency shifting liquid metal antenna with pressure responsiveness
Khan, M. R., Hayes, G. J., So, J., Lazzi, G., & Dickey, M. D. (2011) · Applied Physics Letters · doi:10.1063/1.3603961 · Cited by 135
Self-citationTakegami, S., Yamada, H., & Tsujii, S. (1992) · Journal of Membrane Science · doi:10.1016/0376-7388(92)80009-9 · Cited by 103
French, S. J., Saunders, D. J., & Ingle, G. W. (1938) · The Journal of Physical Chemistry · doi:10.1021/j100897a011 · Cited by 90
Stretchable Conductive Composites Based on Metal Wools for Use as Electrical Vias in Soft Devices
Lessing, J., Morin, S. A., Keplinger, C., Tayi, A. S., & Whitesides, G. M. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201403396 · Cited by 40
Mays, R. L., Dickey, M. D., & Genzer, J. (2013) · Lab on a Chip · doi:10.1039/c3lc50848j · Cited by 9
Self-citation
Cited by
Stretchable and Soft Electronics using Liquid Metals
Dickey, M. D. (2017) · Advanced Materials · doi:10.1002/adma.201606425 · Cited by 1,776
Self-citationMarkvicka, E. J., Bartlett, M. D., Huang, X., & Majidi, C. (2018) · Nature Materials · doi:10.1038/s41563-018-0084-7 · Cited by 1,067
Nature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Advances in liquid metals for biomedical applications
Yan, J., Lu, Y., Chen, G., Yang, M., & Gu, Z. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00309a · Cited by 517
Attributes, Fabrication, and Applications of Gallium‐Based Liquid Metal Particles
Lin, Y., Genzer, J., & Dickey, M. D. (2020) · Advanced Science · doi:10.1002/advs.202000192 · Cited by 503
Self-citation
Metadata
- Authors
- Lin, Y., Cooper, C., Wang, M., Adams, J. J., Genzer, J., & Dickey, M. D.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2015-11-16
- Volume
- 11
- Issue
- 48
- Pages
- 6397-6403
- ISSN
- 1613-6810 (ISSN-L)
- OpenAlex
- W2271132843
- Cited by
- 310
- References
- 31
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.