The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A Robust Intrinsically Green Fluorescent Poly(Amidoamine) Dendrimer for Imaging and Traceable Central Nervous System Delivery in Zebrafish
Abstract
Intrinsically fluorescent poly(amidoamine) dendrimers (IF‐PAMAM) are an emerging class of versatile nanoplatforms for in vitro tracking and bio‐imaging. However, limited tissue penetration of their fluorescence and interference due to auto‐fluorescence arising from biological tissues limit its application in vivo. Herein, a green IF‐PAMAM (FGP) dendrimer is reported and its biocompatibility, circulation, biodistribution and potential role for traceable central nervous system (CNS)‐targeted delivery in zebrafish is evaluated, exploring various routes of administration. Key features of FGP include visible light excitation (488 nm), high fluorescence signal intensity, superior photostability and low interference from tissue auto‐fluorescence. After intravenous injection, FGP shows excellent imaging and tracking performance in zebrafish. Further conjugating FGP with transferrin (FGP‐Tf) significantly increases its penetration through the blood–brain barrier (BBB) and prolongs its circulation in the blood stream. When administering through local intratissue microinjection, including intracranial and intrathecal injection in zebrafish, both FGP and FGP‐Tf exhibit excellent tissue diffusion and effective cellular uptake in the brain and spinal cord, respectively. This makes FGP/FGP‐Tf attractive for in vivo tracing when transporting to the CNS is desired. The work addresses some of the major shortcomings in IF‐PAMAM and provides a promising application of these probes in the development of drug delivery in the CNS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nichols, J. A., & Katiyar, S. K. (2010) · Archives of Dermatological Research · doi:10.1007/s00403-009-1001-3 · Cited by 1,103
Cell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Lee, B., Lee, K., Panda, S., Gonzales-Rojas, R., Chong, A., Bugay, V., Park, H. M., Brenner, R., Murthy, N., & Lee, H. Y. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0252-8 · Cited by 361
Nanotechnology-based strategies for siRNA brain delivery for disease therapy
Zheng, M., Tao, W., Zou, Y., Farokhzad, O. C., & Shi, B. (2018) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.01.006 · Cited by 210
Self-citationSaitoh, Y., Miyanishi, A., Mizuno, H., Kato, S., Aoshima, H., Kokubo, K., & Miwa, N. (2011) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/j.jphotobiol.2010.09.006 · Cited by 86
Cited by
Electrospinning for drug delivery applications: A review
Luraghi, A., Peri, F., & Moroni, L. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.03.033 · Cited by 746
Metal–organic frameworks (MOFs) beyond crystallinity: amorphous MOFs, MOF liquids and MOF glasses
Fonseca, J., Gong, T., Jiao, L., & Jiang, H.-L. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta01043c · Cited by 543
Microfluidic formulation of nanoparticles for biomedical applications
Shepherd, S. J., Issadore, D., & Mitchell, M. J. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120826 · Cited by 433
Nguyen, D. C., Luyen Doan, T. L., Prabhakaran, S., Tran, D. T., Kim, D. H., Lee, J. H., & Kim, N. H. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.105750 · Cited by 385
Zhang, Y., Wu, B., Mu, G., Ma, C., Mu, D., & Wu, F. (2022) · Journal of Energy Chemistry · doi:10.1016/j.jechem.2021.04.013 · Cited by 321
Metadata
- Authors
- Wang, G., Zhao, X., Wu, H., Lovejoy, D. B., Zheng, M., Lee, A., Fu, L., Miao, K., An, Y., Sayyadi, N., Ding, K., Chung, R. S., Lu, Y., Li, J., Morsch, M., & Shi, B.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2020-09-02
- Volume
- 16
- Issue
- 39
- Pages
- e2003654-e2003654
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W3082226880
- Cited by
- 235
- References
- 5
- FWCI
- 21.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Robust Intrinsically Green Fluorescent Poly(Amidoamine) Dendrimer for Imaging and Traceable Central Nervous System Delivery in Zebrafish. https://app.cochat.ai/papers/10.1002/smll.202003654
- The paper
- Wang, G., Zhao, X., Wu, H., Lovejoy, D. B., Zheng, M., Lee, A., Fu, L., Miao, K., An, Y., Sayyadi, N., Ding, K., Chung, R. S., Lu, Y., Li, J., Morsch, M., & Shi, B. (2020). A Robust Intrinsically Green Fluorescent Poly(Amidoamine) Dendrimer for Imaging and Traceable Central Nervous System Delivery in Zebrafish. Small. https://doi.org/10.1002/smll.202003654
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.