Cited by 8Sulfur Compounds in BiologyNanoplatforms for cancer theranosticsMolecular Sensors and Ion Detection

The DOI matches its Crossref record.

A Hydrogen Sulfide‐Activated NIR‐II Fluorescence/NIR‐I Photoacoustic Dual‐Ratiometric Nanoprobe With Unique Recognition Reaction for Precise Visual Diagnosis of Hepatitis Disease

Abstract

Hydrogen sulfide (H 2 S) is a vital gaseous signaling molecule that plays a central role in various physiological and pathological processes. Given the complementary advantages of fluorescence (FL) and photoacoustic (PA) imaging, there is a growing demand for dual‐ratiometric probes that enable precise in vivo monitoring of H 2 S levels. In this study, the use of 2‐mercapto‐1,3,4‐thiadiazole (MTD) as a novel recognition group of H 2 S is presented for the first time, following conjugation with cyanine dyes to obtain a new PA probe Cy‐MTD. To achieve dual‐ratiometric imaging, Cy‐MTD is incorporated into down‐conversion nanoparticle (DCNP), resulting in the creation of a pioneering NIR‐II FL/NIR‐I PA dual‐ratiometric nanoprobe DCNP@Cy‐MTD. Cy‐MTD undergoes the blueshift in absorption from 840 to 670 nm after reaction with H 2 S, enabling NIR‐I ratiometric PA imaging of H 2 S by measuring the ratio of PA signal at 670 and 840 nm (PA 670/PA 840). In addition, due to the strong absorption of Cy‐MTD ≈840 nm and the overlapping between the absorption spectrum of Cy‐MTD and 808 nm excitation band of DCNP, the 808 nm‐excited FL emission (F 1550 nm,808Ex) of DCNP in DCNP@Cy‐MTD nanoprobe is quenched through the competitive absorption, while it is restored upon the interaction with H 2 S because of the blueshift in absorption of Cy‐MTD. Using the stable FL emission of DCNP under 980 nm excitation (F 1550 nm,980Ex) as the reference signal, NIR‐II ratiometric FL imaging (F 1550 nm,808Ex/F 1550 nm,980Ex) of H 2 S is achieved. The dual‐ratiometric response features of the DCNP@Cy‐MTD nanoprobe offer a significant advancement over traditional single‐signal or single‐modality imaging techniques. By providing enhanced accuracy and reliability, this probe allows for the diagnosis of hepatitis by monitoring the H 2 S, surpassing the capabilities of conventional histopathological methods, which provides a new way for more effective diagnostic strategies for liver diseases.

Overview

Integrity signals

Registry

Crossref · 10.1002/smll.202501269

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 52

  1. 10.1089/ars.2014.6082 · DOI
  2. 10.1002/anie.202209248 · DOI
  3. 10.1021/acs.jmedchem.7b00888 · DOI
  4. 10.1126/science.1162667 · DOI · Paper page
  5. 10.1038/nrd2425 · DOI
  6. 10.1021/acs.chemrev.7b00205 · DOI
  7. 10.1089/ars.2014.5901 · DOI · Paper page
  8. 10.1038/s41392-020-00410-5 · DOI
  9. 10.1021/acs.analchem.2c03254 · DOI
  10. 10.1021/acs.nanolett.3c03980 · DOI
  11. 10.1021/jacs.8b10176 · DOI
  12. 10.1002/anie.201712528 · DOI
  13. 10.1021/acs.analchem.3c00449 · DOI
  14. 10.1021/acs.analchem.5b03636 · DOI
  15. 10.1021/acs.analchem.2c05364 · DOI
  16. 10.1155/2015/295241 · DOI
  17. 10.1021/jacs.9b09181 · DOI
  18. 10.1016/j.cclet.2023.108913 · DOI
  19. 10.1039/c2cc34031c · DOI
  20. 10.1021/acs.chemrev.3c00776 · DOI
  21. 10.1038/s41467-018-05113-8 · DOI
  22. 10.1021/acs.analchem.2c05333 · DOI
  23. 10.1021/jacs.0c07022 · DOI · Paper page
  24. 10.1002/anie.202305744 · DOI
  25. 10.1021/acs.analchem.1c00427 · DOI
  26. 10.1002/anie.202406694 · DOI
  27. 10.1002/advs.202306375 · DOI
  28. 10.1016/j.cej.2024.154172 · DOI
  29. 10.1038/s41557-021-00804-0 · DOI
  30. 10.1002/adma.201802394 · DOI
  31. 10.1007/s12274-020-3000-9 · DOI
  32. 10.1016/j.ccr.2024.215907 · DOI
  33. 10.1016/j.biomaterials.2024.122765 · DOI
  34. 10.1016/j.biomaterials.2024.122635 · DOI
  35. 10.1021/acsnano.3c10659 · DOI
  36. 10.1021/acssensors.3c02322 · DOI
  37. 10.1002/anie.202107076 · DOI
  38. 10.1002/ange.202418378 · DOI
  39. 10.1021/acs.nanolett.8b05148 · DOI
  40. 10.1039/c3sc50369k · DOI
  41. 10.1002/smll.202002939 · DOI
  42. 10.1039/C9CC02224D · DOI
  43. 10.1021/jacs.7b00223 · DOI
  44. 10.1002/ange.202108124 · DOI
  45. 10.1038/ncomms3199 · DOI
  46. 10.1039/D3SC02338A · DOI
  47. 10.1002/adfm.202009942 · DOI · Paper page
  48. 10.1002/adfm.202414772 · DOI
  49. 10.1096/fj.04-3583fje · DOI
  50. 10.1021/acsnano.0c09799 · DOI
  51. 10.1021/acs.nanolett.1c00548 · DOI
  52. 10.1002/anie.202209248 · DOI

Cited by

Sorted by citations

See all 8

Metadata

Authors
Huang, L., Lv, F., Bin, Y., Zhao, J., Li, C., Zhao, S., Hu, S., & Zhang, L.
Affiliations
Guangxi Normal University (CN)
Corresponding author
  • Zhao, Shulin
  • Zhang, Liangliang
Venue
Small
Publisher
Wiley
Published
2025-04-24
Volume
21
Issue
23
Pages
e2501269-e2501269
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W4409773204
Cited by
8
References
0
Citations by year
2026: 7 · 2025: 1
FWCI
2.58
Type
journal article
Language
en
Open access
closed
Locations
  • Small (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (22174026, 22466008)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Sulfur Compounds in Biology
  • Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
Keywords
hydrogen sulfide, NIR-II fluorescence, cyanine dyes, hepatitis diagnosis, in vivo imaging, liver disease biomarkers, bioconjugation
MeSH terms
Animals, Fluorescence, Fluorescent Dyes, Humans, Hydrogen Sulfide, Spectroscopy, Near-Infrared, Mice, Nanoparticles, Photoacoustic Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review