The DOI matches its Crossref record.
A Hydrogen Sulfide‐Activated NIR‐II Fluorescence/NIR‐I Photoacoustic Dual‐Ratiometric Nanoprobe With Unique Recognition Reaction for Precise Visual Diagnosis of Hepatitis Disease
Abstract
Hydrogen sulfide (H 2 S) is a vital gaseous signaling molecule that plays a central role in various physiological and pathological processes. Given the complementary advantages of fluorescence (FL) and photoacoustic (PA) imaging, there is a growing demand for dual‐ratiometric probes that enable precise in vivo monitoring of H 2 S levels. In this study, the use of 2‐mercapto‐1,3,4‐thiadiazole (MTD) as a novel recognition group of H 2 S is presented for the first time, following conjugation with cyanine dyes to obtain a new PA probe Cy‐MTD. To achieve dual‐ratiometric imaging, Cy‐MTD is incorporated into down‐conversion nanoparticle (DCNP), resulting in the creation of a pioneering NIR‐II FL/NIR‐I PA dual‐ratiometric nanoprobe DCNP@Cy‐MTD. Cy‐MTD undergoes the blueshift in absorption from 840 to 670 nm after reaction with H 2 S, enabling NIR‐I ratiometric PA imaging of H 2 S by measuring the ratio of PA signal at 670 and 840 nm (PA 670/PA 840). In addition, due to the strong absorption of Cy‐MTD ≈840 nm and the overlapping between the absorption spectrum of Cy‐MTD and 808 nm excitation band of DCNP, the 808 nm‐excited FL emission (F 1550 nm,808Ex) of DCNP in DCNP@Cy‐MTD nanoprobe is quenched through the competitive absorption, while it is restored upon the interaction with H 2 S because of the blueshift in absorption of Cy‐MTD. Using the stable FL emission of DCNP under 980 nm excitation (F 1550 nm,980Ex) as the reference signal, NIR‐II ratiometric FL imaging (F 1550 nm,808Ex/F 1550 nm,980Ex) of H 2 S is achieved. The dual‐ratiometric response features of the DCNP@Cy‐MTD nanoprobe offer a significant advancement over traditional single‐signal or single‐modality imaging techniques. By providing enhanced accuracy and reliability, this probe allows for the diagnosis of hepatitis by monitoring the H 2 S, surpassing the capabilities of conventional histopathological methods, which provides a new way for more effective diagnostic strategies for liver diseases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This nanoprobe enabled the real-time dynamic quantification of H2S by simultaneously leveraging NIR-II fluorescence and NIR-I PA signals.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [102]
In the citing paper
“This spectral shift enabled the ratiometric PA imaging of H2S based on the signal ratio at 670 nm and 840 nm (PA670/PA840).”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [102]
In the citing paper
“Consequently, when conjugated to the DCNP surface, Cy-MTD acted as an optical filter, quenching the DCNP’s 1550 nm emission (under 808 nm excitation) via competitive absorption quenching.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [102]
In the citing paper
“Cy-MTD exhibited a strong absorption peak at 840 nm, with its absorption spectrum overlapping the 808 nm excitation band of the DCNP core.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [102]
In the citing paper
“In the presence of H2S, Cy-MTD underwent a specific molecular transformation, causing a significant blue-shift in its absorption peak from 840 nm to 670 nm.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [102]
In the citing paper
“Building upon this, they further fabricated a novel dual-ratiometric nanoprobe DCNP@Cy-MTD by integrating Cy-MTD onto a down-conversion nanoparticle (DCNP).”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [102]
In the citing paper
“Zhang et al. identified 2-mercapto-1,3,4-thiadiazole (MTD) as an H2S-responsive unit and conjugated it to a cyanine scaffold to create the ratiometric PA probe Cy-MTD102.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [102]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 52
- 10.1089/ars.2014.6082 · DOI
- 10.1002/anie.202209248 · DOI
- 10.1021/acs.jmedchem.7b00888 · DOI
- 10.1126/science.1162667 · DOI · Paper page
- 10.1038/nrd2425 · DOI
- 10.1021/acs.chemrev.7b00205 · DOI
- 10.1089/ars.2014.5901 · DOI · Paper page
- 10.1038/s41392-020-00410-5 · DOI
- 10.1021/acs.analchem.2c03254 · DOI
- 10.1021/acs.nanolett.3c03980 · DOI
- 10.1021/jacs.8b10176 · DOI
- 10.1002/anie.201712528 · DOI
- 10.1021/acs.analchem.3c00449 · DOI
- 10.1021/acs.analchem.5b03636 · DOI
- 10.1021/acs.analchem.2c05364 · DOI
- 10.1155/2015/295241 · DOI
- 10.1021/jacs.9b09181 · DOI
- 10.1016/j.cclet.2023.108913 · DOI
- 10.1039/c2cc34031c · DOI
- 10.1021/acs.chemrev.3c00776 · DOI
- 10.1038/s41467-018-05113-8 · DOI
- 10.1021/acs.analchem.2c05333 · DOI
- 10.1021/jacs.0c07022 · DOI · Paper page
- 10.1002/anie.202305744 · DOI
- 10.1021/acs.analchem.1c00427 · DOI
- 10.1002/anie.202406694 · DOI
- 10.1002/advs.202306375 · DOI
- 10.1016/j.cej.2024.154172 · DOI
- 10.1038/s41557-021-00804-0 · DOI
- 10.1002/adma.201802394 · DOI
- 10.1007/s12274-020-3000-9 · DOI
- 10.1016/j.ccr.2024.215907 · DOI
- 10.1016/j.biomaterials.2024.122765 · DOI
- 10.1016/j.biomaterials.2024.122635 · DOI
- 10.1021/acsnano.3c10659 · DOI
- 10.1021/acssensors.3c02322 · DOI
- 10.1002/anie.202107076 · DOI
- 10.1002/ange.202418378 · DOI
- 10.1021/acs.nanolett.8b05148 · DOI
- 10.1039/c3sc50369k · DOI
- 10.1002/smll.202002939 · DOI
- 10.1039/C9CC02224D · DOI
- 10.1021/jacs.7b00223 · DOI
- 10.1002/ange.202108124 · DOI
- 10.1038/ncomms3199 · DOI
- 10.1039/D3SC02338A · DOI
- 10.1002/adfm.202009942 · DOI · Paper page
- 10.1002/adfm.202414772 · DOI
- 10.1096/fj.04-3583fje · DOI
- 10.1021/acsnano.0c09799 · DOI
- 10.1021/acs.nanolett.1c00548 · DOI
- 10.1002/anie.202209248 · DOI
Cited by
Sorted by citations
Organic small-molecule NIR-II fluorophores for tumor phototheranostics
Xiang, D., Wang, Z., Zheng, H., Tang, Y., & Li, Q. (2026) · Light: Science & Applications · doi:10.1038/s41377-026-02212-w · Cited by 22
Metadata
- Authors
- Huang, L., Lv, F., Bin, Y., Zhao, J., Li, C., Zhao, S., Hu, S., & Zhang, L.
- Affiliations
- Guangxi Normal University (CN)
- Corresponding author
- Zhao, Shulin
- Zhang, Liangliang
- Venue
- Small
- Publisher
- Wiley
- Published
- 2025-04-24
- Volume
- 21
- Issue
- 23
- Pages
- e2501269-e2501269
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W4409773204
- Cited by
- 8
- References
- 0
- Citations by year
- 2026: 7 · 2025: 1
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Small (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (22174026, 22466008)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Sulfur Compounds in Biology
- Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Keywords
- hydrogen sulfide, NIR-II fluorescence, cyanine dyes, hepatitis diagnosis, in vivo imaging, liver disease biomarkers, bioconjugation
- MeSH terms
- Animals, Fluorescence, Fluorescent Dyes, Humans, Hydrogen Sulfide, Spectroscopy, Near-Infrared, Mice, Nanoparticles, Photoacoustic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review