Practical design issues of tuned mass dampers for torsionally coupled buildings under earthquake loadings
Abstract
In this study, a new design procedure was developed for reducing the dynamic responses of torsionally coupled buildings, particularly existing buildings, under bilateral earthquake excitations, by incorporating the vibration control effectiveness of passive tuned mass dampers (PTMDs) . Some practical design issues such as the optimal location for installation, movement direction and numbers of PTMD are considered in this study. The optimal parameters of the PTMD system are determined by minimizing the mean square displacement response ratio of the controlled degree of freedom between the building with and without PTMDs. In addition, parametric studies of the PTMD planar position and the detuning effect are undertaken to determine their influence on the response control efficacy. The numerical results from two typical multistory torsionally coupled buildings under bidirectional ground accelerations, recorded at the 1979 El Centro earthquake, verify that the proposed optimal PTMDs are more effective and more robust in reducing the building responses. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The result shows that the response control for two PTMDs installed in two orthogonal directions produced a better performance than one PTMD installed in a weaker direction when both cases had the same total PTMD mass.”
From Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review (2020) · cites this paper as [66]
Citations
Cites
Parametric study and simplified design of tuned mass dampers
Rana, R., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00078-3 · Cited by 651
Research works printed but not linked: 35
- 10.1002/eqe.4290230802 · DOI · Paper page
- 10.1002/eqe.4290240209 · DOI
- Asami T, 1991, Optimum design of dynamic absorbers for a system subjected to random excitation, JSME International Journal, 34, 218
- 10.1002/eqe.4290221002 · DOI · Paper page
- 10.1006/jsvi.1994.1341 · DOI · Paper page
- 10.12989/sem.1995.3.5.497 · DOI
- 10.1002/(SICI)1096-9845(199909)28:9<1041::AID-EQE853>3.0.CO;2-E · DOI
- 10.1002/(SICI)1096-9845(199703)26:3<307::AID-EQE639>3.0.CO;2-8 · DOI
- 10.1016/0167-6105(92)90619-L · DOI
- 10.1061/(ASCE)0733-9399(1984)110:11(1645) · DOI
- 10.1016/0141-0296(90)90002-A · DOI
- 10.1002/1096-9845(200009)29:9<1405::AID-EQE976>3.0.CO;2-4 · DOI
- 10.1002/eqe.128 · DOI · Paper page
- 10.1080/02533839.1994.9677600 · DOI
- LinCC UengJM WangJF.1995.Vibration control identification of MDOF structures with tuned mass damper. InInternational Conference on Structural Dynamics Vibration Noise and Control Vol. 2 Hong Kong;887–894.
- 10.1016/S0141-0296(98)00054-6 · DOI
- 10.1006/jsvi.2000.3188 · DOI
- 10.1061/(ASCE)1084-0702(2005)10:4(398) · DOI
- Luft RW., 1979, Optimal tuned mass dampers for buildings, Journal of Structural Division, ASCE, 105, 2766, 10.1061/JSDEAG.0005323 · DOI
- McNamara RJ., 1977, Tuned mass dampers for buildings, Journal of the Structural Division, ASCE, 103, 1785, 10.1061/JSDEAG.0004721 · DOI
- 10.1016/S0141-0296(00)00095-X · DOI
- 10.1139/l86-039 · DOI
- 10.1006/jsvi.1996.0449 · DOI
- 10.1061/(ASCE)0733-9445(1992)118:3(741) · DOI
- 10.1002/eqe.119 · DOI
- 10.1006/jsvi.1994.0367 · DOI
- Thornton CH, 1990, Taming structural vibrations, Civil Engineering, 60, 57
- UengJM LinCC.1996.Design and vibration control of passive tuned mass dampers for torsionally‐coupled buildings. InThird National Conference on Structural Engineering Vol. 3 Kenting Taiwan 1–3 September;2073–2082(in Chinese).
- UengJM LinCC ChenBR HuangTC.1998.Practical considerations in TMD design for vibration control of buildings. InSixth East Asia–Pacific Conference on Structural Engineering and Construction Taipei Taiwan 14–16 January.
- 10.1002/eqe.4290220603 · DOI
- 10.1016/j.ijsolstr.2005.02.042 · DOI · Paper page
- 10.1002/eqe.4290100304 · DOI
- 10.1002/eqe.4290020402 · DOI
- 10.1061/(ASCE)0733-9445(1994)120:3(747) · DOI
- Xu YL, 1992, Control of along‐wind response of structures by mass and liquid dampers, Journal of Engineering Mechanics, ASCE, 118, 20, 10.1061/(ASCE)0733-9399(1992)118:1(20) · DOI
Cited by
Sorted by citations
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
Metadata
- Authors
- Ueng, J., Lin, C., & Wang, J.
- Affiliations
- National Chung Hsing University (TW)
- Corresponding author
- Lin, Chi‐Chang
- ORCID
- Lin, Chi‐Chang
- Venue
- The Structural Design of Tall and Special Buildings
- Publisher
- Wiley
- Published
- 2007-06-18
- Volume
- 17
- Issue
- 1
- Pages
- 133-165
- ISSN
- 1541-7794 (ISSN-L)
- 1541-7808
- OpenAlex
- W2047226676
- Cited by
- 36
- References
- 1
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 5 · 2022: 3 · 2021: 3 · 2020: 3 · 2019: 4 · 2018: 3 · 2017: 1 · 2016: 1 · 2015: 2 · 2013: 2 · 2012: 2
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Structural Design of Tall and Special Buildings (publishedVersion)
- Funders
- National Science Council
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic and Structural Analysis of Tall Buildings
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic Performance and Analysis
- Keywords
- tuned mass damper, passive vibration control, damper placement optimization, existing buildings, El Centro earthquake, multi-storey buildings
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review