An integrated model with classification criteria to predict small‐for‐gestational‐age fetuses at risk of adverse perinatal outcome
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Objective: To develop an integrated model with the best performing criteria for predicting adverse outcome in small‐for‐gestational‐age (SGA) pregnancies. Methods: A cohort of 509 pregnancies with a suspected SGA fetus, eligible for trial of labor, was recruited prospectively and data on perinatal outcome were recorded. A predictive model for emergency Cesarean delivery because of non‐reassuring fetal status or neonatal acidosis was constructed using a decision tree analysis algorithm, with predictors: maternal age, body mass index, smoking, nulliparity, gestational age at delivery, onset of labor (induced vs spontaneous), estimated fetal weight (EFW), umbilical artery pulsatility index (PI), mean uterine artery (UtA) PI, fetal middle cerebral artery PI and cerebroplacental ratio (CPR). Results: An adverse outcome occurred in 134 (26.3%) cases. The best performing predictors for defining a high risk for adverse outcome in SGA fetuses was the presence of a CPR < 10 th centile, a mean UtA‐PI > 95 th centile or an EFW < 3 rd centile. The algorithm showed a sensitivity, specificity and positive and negative predictive values for adverse outcome of 82.8% (95% CI, 75.1–88.6%), 47.7% (95% CI, 42.6–52.9%), 36.2% (95% CI, 30.8–41.8%) and 88.6% (95% CI, 83.2–92.5%), respectively. Positive and negative likelihood ratios were 1.58 and 0.36. Conclusions: Our model could be used as a diagnostic tool for discriminating SGA pregnancies at risk of adverse perinatal outcome. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., & Vandenbroucke, J. P. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61602-x · Cited by 21,320
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
Timing of Indicated Late-Preterm and Early-Term Birth
Spong, C. Y., Mercer, B. M., D'Alton, M., Kilpatrick, S., Blackwell, S., & Saade, G. (2011) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3182255999 · Cited by 581
Progression of Doppler abnormalities in intrauterine growth restriction
Turan, O. M., Turan, S., Gungor, S., Berg, C., Moyano, D., Gembruch, U., Nicolaides, K. H., Harman, C. R., & Baschat, A. A. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5386 · Cited by 353
Oros, D., Figueras, F., Cruz‐Martinez, R., Meler, E., Munmany, M., & Gratacos, E. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7738 · Cited by 256 · cited 3×
“Continuous fetal-heart monitoring was carried out and tracings were classified according to the following three-tiered system25: (1) normal: baseline of 110–160 beats per minute (bpm), variability > 5 bpm and absence of decelerations; (2) suspicious, i.”
BackgroundMethodSelf-citationSeveri, F. M., Bocchi, C., Visentin, A., Falco, P., Cobellis, L., Florio, P., Zagonari, S., & Pilu, G. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2002.00652.x · Cited by 248
Savchev, S., Figueras, F., Sanz-Cortes, M., Cruz-Lemini, M., Triunfo, S., Botet, F., & Gratacos, E. (2014) · Fetal Diagnosis and Therapy · doi:10.1159/000355525 · Cited by 182
Self-citationSavchev, S., Figueras, F., Cruz‐Martinez, R., Illa, M., Botet, F., & Gratacos, E. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10150 · Cited by 160
Self-citation
Cited by
Andreoli, L., Bertsias, G. K., Agmon-Levin, N., Brown, S., Cervera, R., Costedoat-Chalumeau, N., Doria, A., Fischer-Betz, R., Forger, F., Moraes-Fontes, M. F., et al. (2017) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2016-209770 · Cited by 945
Melamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Self-citationDeVore, G. R. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2015.05.024 · Cited by 317
Diagnosis and surveillance of late-onset fetal growth restriction
Figueras, F., Caradeux, J., Crispi, F., Eixarch, E., Peguero, A., & Gratacos, E. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.003 · Cited by 300
Self-citationCaradeux, J., Martinez-Portilla, R. J., Peguero, A., Sotiriadis, A., & Figueras, F. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.043 · Cited by 122
Self-citation
Metadata
- Authors
- Figueras, F., Savchev, S., Triunfo, S., Crovetto, F., & Gratacos, E.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2015-01-27
- Volume
- 45
- Issue
- 3
- Pages
- 279-285
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2140490166
- Cited by
- 152
- References
- 8
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An integrated model with classification criteria to predict small‐for‐gestational‐age fetuses at risk of adverse perinatal outcome. https://app.cochat.ai/papers/10.1002/uog.14714
- The paper
- Figueras, F., Savchev, S., Triunfo, S., Crovetto, F., & Gratacos, E. (2015). An integrated model with classification criteria to predict small‐for‐gestational‐age fetuses at risk of adverse perinatal outcome. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.14714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.