The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Single deepest vertical pocket or amniotic fluid index as evaluation test for predicting adverse pregnancy outcome (SAFE trial): a multicenter, open‐label, randomized controlled trial
Open accessAbstract
Objective: To determine whether the amniotic fluid index (AFI) or the single deepest vertical pocket (SDP) technique for estimating amniotic fluid volume is superior for predicting adverse pregnancy outcome. Methods: This was a multicenter randomized controlled trial including 1052 pregnant women with a term singleton pregnancy across four hospitals in Germany. Women were assigned randomly, according to a computer‐generated allocation sequence, to AFI or SDP measurement for estimation of amniotic fluid volume. Oligohydramnios was defined as AFI ≤ 5 cm or the absence of a pocket measuring at least 2 × 1 cm. The diagnosis of oligohydramnios was followed by labor induction. The primary outcome measure was postpartum admission to a neonatal intensive care unit. Further outcome parameters were the rates of diagnosis of oligohydramnios and induction of labor (for oligohydramnios or without specific indication), and mode of delivery. Results: Postpartum admission to a neonatal intensive care unit was similar between groups (4.2% (n = 21) vs 5.0% (n = 25); relative risk (RR), 0.85 (95% CI, 0.48–1.50); P = 0.57). In the AFI group, there were more cases of oligohydramnios (9.8% (n = 49) vs 2.2% (n = 11); RR, 4.51 (95% CI, 2.2–8.57); P < 0.01) and more cases of labor induction for oligohydramnios (12.7% (n = 33) vs 3.6% (n = 10); RR, 3.50 (95% CI, 1.76–6.96); P < 0.01) than in the SDP group. Moreover, an abnormal cardiotocography was seen more often in the AFI group than in the SDP group (32.3% (n = 161) vs 26.2% (n = 132); RR, 1.23 (95% CI, 1.02–1.50); P = 0.03). The other outcome measures were not significantly different between the two groups. Conclusions: Use of the AFI method increased the rate of diagnosis of oligohydramnios and labor induction for oligohydramnios without improving perinatal outcome. The SDP method is therefore the favorable method to estimate amniotic fluid volume, especially in a population with many low‐risk pregnancies. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, it appears that AFI identifies more women as having oligohydramnios than does DVP, thereby increasing the rate of labor induction, but without improving the clinical outcome 37,38 .”
From ISUOG Practice Guidelines (updated): performance of the routine mid‐trimester fetal ultrasound scan (2022) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1987) · PubMed · Cited by 639
Ultrasound evaluation of amniotic fluid volume
Chamberlain, P. F., Manning, F. A., Morrison, I., Harman, C. R., & Lange, I. R. (1984) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(84)90359-4 · Cited by 526
Investigation and management of the small for gestational age fetus
Bullough, S., Navaratnam, K., & Sharp, A. (2020) · Obstetrics Gynaecology & Reproductive Medicine · doi:10.1016/j.ogrm.2020.11.002 · Cited by 315
Nabhan, A. F., & Abdelmoula, Y. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006593.pub2 · Cited by 202
Fetal biophysical profile scoring: A prospective study in 1,184 high-risk patients
Manning, F. A., Baskett, T. F., Morrison, I., & Lange, I. R. (1981) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(81)90275-1 · Cited by 189
Clark, S. L., Sabey, P., & Jolley, K. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(89)80062-6 · Cited by 170
Morris, J. M., Thompson, K., Smithey, J., Gaffney, G., Cooke, I., Chamberlain, P. F., Hope, P. L., Altman, D. G., & MacKenzie, I. Z. (2003) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2003.02417.x · Cited by 163
A Review of Amniotic Fluid Dynamics and the Enigma of Isolated Oligohydramnios
Sherer, D. M. (2002) · American Journal of Perinatology · doi:10.1055/s-2002-33084 · Cited by 121
Chauhan, S. P., Doherty, D. D., Magann, E. F., Cahanding, F., Moreno, F. V., & Klausen, J. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.06.078 · Cited by 82
Magann, E. F., Kinsella, M. J., Chauhan, S. P., McNamara, M. F., Gehring, B. W., & Morrison, J. C. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70019-0 · Cited by 74
Alfirević, Ž., Luckas, M. J. M., Walkinshaw, S. A., McFarlane, M., & Curran, R. (1997) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1997.tb11046.x · Cited by 67
The Evidence for Abandoning the Amniotic Fluid Index in Favor of the Single Deepest Pocket
Magann, E., Chauhan, S., Doherty, D., Magann, M., & Morrison, J. (2007) · American Journal of Perinatology · doi:10.1055/s-2007-986689 · Cited by 65
Moses, J., Doherty, D. A., Magann, E. F., Chauhan, S. P., & Morrison, J. C. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.046 · Cited by 61
Biophysical Profile With Amniotic Fluid Volume Assessments
Magann, E. F., Doherty, D. A., Field, K., Chauhan, S. P., Muffley, P. E., & Morrison, J. C. (2004) · Obstetrics and Gynecology · doi:10.1097/01.aog.0000131618.14176.00 · Cited by 60
A Randomized study to assess the efficacy of the amniotic fluid index as a fetal admission test
Chauhan, S. P., Washburne, J. F., Magann, E. F., PERRYJR, K., MARTINJR, J., & Morrison, J. C. (1995) · Obstetrics and Gynecology · doi:10.1016/0029-7844(95)00110-d · Cited by 53
Magann, E. F., Chauhan, S. P., Bofill, J. A., & Martin, J. N., Jr. (2003) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1046/j.0004-8666.2003.00002.x · Cited by 40
Amniotic fluid volume estimation and the biophysical profile: a confusion of criteria
Magann, E. F. (2000) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(99)00634-1 · Cited by 34
Research works printed but not linked: 1
- Nabhan AF, 2008, Cochrane Database Syst Rev
Cited by
Sorted by citations
ISUOG Practice Guidelines (updated): performance of the routine mid‐trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C. M., Chalouhi, G. E., Da Silva Costa, F., Hernandez‐Andrade, E., Malinger, G., Munoz, H., Paladini, D., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24888 · Cited by 436
(2018) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14831 · Cited by 216
Oligohydramnios in complicated and uncomplicated pregnancy: a systematic review and meta‐analysis
Rabie, N. Z., Magann, E. F., Steelman, S. C., & Ounpraseuth, S. (2016) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.15929 · Cited by 160
Rizzo, G., Mappa, I., Bitsadze, V. O., Słodki, M., Khizroeva, J. K., Makatsariya, A. D., & D’Antonio, F. (2019) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.20406 · Cited by 121
ISUOG Practice Guidelines: performance of third‐trimester obstetric ultrasound scan
Khalil, A. A., Sotiriadis, A., D’Antonio, F., Costa, F. D. S., Odibo, A. O., Prefumo, F., Papageorghiou, A. T., & Salomon, L. J. (2024) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.27538 · Cited by 115
Metadata
- Authors
- Kehl, S., Schelkle, A., Thomas, A., Puhl, A., Meqdad, K., Tuschy, B., Berlit, S., Weiss, C., Bayer, C., Heimrich, J., Dammer, U., Raabe, E., Winkler, M., Faschingbauer, F., Beckmann, M. W., & Sütterlin, M.
- Affiliations
- Heidelberg University (DE)
- Charité – Universitätsmedizin Berlin (DE)
- University Medical Center of the Johannes Gutenberg University Mainz (DE)
- Universitätsklinikum Erlangen (DE)
- Corresponding author
- Kehl, S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2016-06
- Volume
- 47
- Issue
- 6
- Pages
- 674-679
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1921567863
- Cited by
- 152
- References
- 17
- Citations by year
- 2026: 15 · 2025: 16 · 2024: 11 · 2023: 27 · 2022: 15 · 2021: 14 · 2020: 17 · 2019: 12 · 2018: 11 · 2017: 11 · 2016: 3
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Ultrasound in Obstetrics and Gynecology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Health Sciences › Medicine › Obstetrics and Gynecology › Preterm Birth and Chorioamnionitis
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Keywords
- amniotic fluid index, oligohydramnios, adverse pregnancy outcomes, neonatal intensive care admission, labor induction, cardiotocography, term singleton pregnancy, fetal monitoring, fetal growth restriction, macrosomia, fetal hypoxia, fetal distress, fetal malpresentation, fetal malposition
- MeSH terms
- Amniotic Fluid, Female, Humans, Labor, Induced, Patient Admission, Predictive Value of Tests, Pregnancy, Pregnancy Outcome, Intensive Care, Neonatal, Oligohydramnios, Ultrasonography, Prenatal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review