CoChat

Quality control of ultrasound for fetal biometry: results from the INTERGROWTH‐21st Project

Open access
Cavallaro, A., Ash, S. T., Napolitano, R., Wanyonyi, S., Ohuma, E. O., Molloholli, M., Sande, J., Sarris, I., Ioannou, C., Norris, T., Donadono, V., Carvalho, M., Purwar, M., Barros, F. C., Jaffer, Y. A., Bertino, E., Pang, R., Gravett, M. G., Salomon, L. J., Noble, J. A., Altman, D. G., Papageorghiou, A. T. · 2018 · Ultrasound in Obstetrics & Gynecology
Cited by 59

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Objective: To assess a comprehensive package of ultrasound quality control in the Fetal Growth Longitudinal Study of the INTERGROWTH‐21 st Project, a large multicenter study of fetal growth. Methods: Quality control (QC) measures were performed for 20 313 ultrasound scan images obtained prospectively from 4321 fetuses at 14–41 weeks' gestation in eight geographical locations. At the time of each ultrasound examination, three fetal biometric variables (head circumference (HC), abdominal circumference (AC) and femur length (FL)) were measured in triplicate on separately generated images. All measurements were taken in a blinded fashion. QC had two elements: (1) qualitative QC: visual assessment by sonographers at each study site of their images based on specific criteria, with 10% of images being re‐assessed at the Oxford‐based Ultrasound Quality Unit (compared using an adjusted kappa statistic); and (2) quantitative QC: assessment of measurement data by comparing the first, second and third measurements (intraobserver variability), remeasurement of caliper replacement in 10% (interobserver variability), both by Bland–Altman plots and plotting frequency histograms of the SD of triplicate measurements and assessing how many were above or below 2 SD of the expected distribution. The system allowed the sonographers' performances to be monitored regularly. Results: A high level of agreement between self‐ and external scoring was demonstrated for all measurements (κ = 0.99 (95% CI, 0.98–0.99) for HC, 0.98 (95% CI, 0.97–0.99) for AC and 0.96 (95% CI, 0.95–0.98) for FL). Intraobserver 95% limits of agreement (LoA) of ultrasound measures for HC, AC and FL were ± 3.3%, ± 5.6% and ± 6.2%, respectively; the corresponding values for interobserver LoA were ± 4.4%, ± 6.0% and ± 5.6%. The SD distribution of triplicate measurements for all biometric variables showed excessive variability for three of 31 sonographers, allowing prompt identification and retraining. Conclusions: Qualitative and quantitative QC monitoring was feasible and highly reproducible in a large multicenter research study, which facilitated the production of high‐quality ultrasound images. We recommend that the QC system we developed is implemented in future research studies and clinical practice. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.18811

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 59

Metadata

Authors
Cavallaro, A., Ash, S. T., Napolitano, R., Wanyonyi, S., Ohuma, E. O., Molloholli, M., Sande, J., Sarris, I., Ioannou, C., Norris, T., Donadono, V., Carvalho, M., Purwar, M., Barros, F. C., Jaffer, Y. A., Bertino, E., Pang, R., Gravett, M. G., Salomon, L. J., Noble, J. A., Altman, D. G., & Papageorghiou, A. T.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2018-07-26
Volume
52
Issue
3
Pages
332-339
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2737916193
Cited by
59
References
10
FWCI
4.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.