CoChat

Gestational sac volume measured by three‐dimensional ultrasound at 11 to 13 + 6 weeks of gestation: relation to chromosomal defects

Open access
Falcon, O., Wegrzyn, P., Faro, C., Peralta, C. F. A., Nicolaides, K. H. · 2005 · Ultrasound in Obstetrics & Gynecology
Cited by 109

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objective: To determine the potential value of measuring the gestational sac volume (GSV) at 11 to 13 + 6 weeks of gestation in screening for chromosomal defects. Methods: The GSV was measured using three‐dimensional (3D) ultrasound in 500 consecutive singleton pregnancies immediately before chorionic villus sampling (CVS) for fetal karyotyping at 11 to 13 + 6 (median 12) weeks of gestation. Results: The fetal karyotype was normal in 417 pregnancies and abnormal in 83. In the chromosomally normal group, the mean GSV increased significantly with gestational age from a mean of 69 mL at 11 weeks to 144 mL at 13 + 6 weeks (the standard deviation was 27 mL). In the chromosomally abnormal group, the mean GSV for gestational age was not significantly different from normal in fetuses with trisomy 21, trisomy 18 and Turner syndrome, but it was smaller in those with triploidy and trisomy 13. However, the mean GSV for crown–rump length (CRL) was significantly larger in trisomy 18, smaller in triploidy and trisomy 13, and not different from normal in trisomy 21 and Turner syndrome. The mean CRL for gestational age was significantly smaller than normal in trisomy 18, triploidy and trisomy 13. Conclusions: The measurement of the GSV at 11 to 13 + 6 weeks of gestation is unlikely to provide useful prediction of the major chromosomal defects. In trisomy 13 and triploidy, the small GSV may be due to early onset fetal growth restriction and reduced amniotic fluid volume. In trisomy 18, the increase in GSV is probably due to the presence of associated fetal abnormalities that interfere with fetal swallowing. Copyright © 2005 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.1898

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 109

Metadata

Authors
Falcon, O., Wegrzyn, P., Faro, C., Peralta, C. F. A., & Nicolaides, K. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2005-05-09
Volume
25
Issue
6
Pages
546-550
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2149079900
Cited by
109
References
4
FWCI
8.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gestational sac volume measured by three‐dimensional ultrasound at 11 to 13 + 6 weeks of gestation: relation to chromosomal defects. https://app.cochat.ai/papers/10.1002/uog.1898
The paper
Falcon, O., Wegrzyn, P., Faro, C., Peralta, C. F. A., & Nicolaides, K. H. (2005). Gestational sac volume measured by three‐dimensional ultrasound at 11 to 13 + 6 weeks of gestation: relation to chromosomal defects. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.1898

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.