Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 268

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

A novel approach to first‐trimester screening for early pre‐eclampsia combining serum PP‐13 and Doppler ultrasound

Open access
Nicolaides, K. H., Bindra, R., Turan, O. M., Chefetz, I., Sammar, M., Meiri, H., Tal, J., Cuckle, H. S.·2006·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: To investigate the value of maternal serum placental protein 13 (PP‐13) measurement and uterine artery Doppler during first‐trimester screening in the prediction of early pre‐eclampsia. Methods: This was a nested case‐control prospective study of pregnancies at 11 + 0 to 13 + 6 weeks of gestation. The pulsatility index (PI) of blood flow in the uterine arteries and the maternal serum concentration of PP‐13 were measured in 10 women who went on to develop pre‐eclampsia that necessitated delivery before 34 weeks, and in 423 unaffected women. Results were expressed as multiples of the gestation‐specific median in controls (MoM). A logistic regression model was used to predict detection and false‐positive rates. Results: In the cases that developed pre‐eclampsia requiring delivery before 34 weeks, compared with the unaffected pregnancies, the median uterine artery PI was higher (1.43 MoM) and the median serum PP‐13 level was lower (0.07 MoM; P < 0.001, Wilcoxon rank sum test for both). Modeling predicted that for a 90% detection rate of pre‐eclampsia requiring delivery before 34 weeks, the false‐positive rate of screening by PP‐13 was 12%, by uterine artery PI was 31% and by a combination of the two methods was 9%. A policy of contingency screening, whereby all women are screened by maternal serum PP‐13 and only the 14% at highest risk are then screened by Doppler, achieved a detection rate of 90% with an overall false‐positive rate of 6%. Conclusion: Effective screening for pre‐eclampsia requiring delivery before 34 weeks can potentially be provided by assessment of a combination of maternal serum PP‐13 and uterine artery Doppler in the first trimester of pregnancy. Copyright © 2005 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.2686

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 268

Metadata

Authors
Nicolaides, K. H., Bindra, R., Turan, O. M., Chefetz, I., Sammar, M., Meiri, H., Tal, J., & Cuckle, H. S.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2005-12-22
Volume
27
Issue
1
Pages
13-17
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2155693947
Cited by
268
References
16
FWCI
17.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel approach to first‐trimester screening for early pre‐eclampsia combining serum PP‐13 and Doppler ultrasound. https://app.cochat.ai/papers/10.1002/uog.2686
The paper
Nicolaides, K. H., Bindra, R., Turan, O. M., Chefetz, I., Sammar, M., Meiri, H., Tal, J., & Cuckle, H. S. (2006). A novel approach to first‐trimester screening for early pre‐eclampsia combining serum PP‐13 and Doppler ultrasound. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.2686

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.