The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detailed screening for fetal anomalies and cardiac defects at the 11–13‐week scan
Open accessAbstract
Objective: To assess the diagnostic efficacy of the first‐trimester anomaly scan including first‐trimester fetal echocardiography as a screening procedure in a ‘medium‐risk’ population. Methods: In a prospective study, we evaluated 3094 consecutive fetuses with a crown–rump length (CRL) of 45–84 mm and gestational age between 11 + 0 and 13 + 6 weeks, using transabdominal and transvaginal ultrasonography. The majority of patients were referred without prior abnormal scan or increased nuchal translucency (NT) thickness, the median maternal age was, however, 35 (range, 15–46) years, and 53.8% of the mothers (1580/2936) were 35 years or older. This was therefore a self‐selected population reflecting an increased percentage of older mothers opting for prenatal diagnosis. The follow‐up rate was 92.7% (3117/3363). Results: The prevalence of major abnormalities in 3094 fetuses was 2.8% (86/3094). The detection rate of major anomalies at the 11 + 0 to 13 + 6‐week scan was 83.7% (72/86), 51.9% (14/27) for NT < 2.5 mm and 98.3% (58/59) for NT ≥ 2.5 mm. The prevalence of major congenital heart defects (CHD) was 1.2% (38/3094). The detection rate of major CHD at the 11 to 13 + 6‐week scan was 84.2% (32/38), 37.5% (3/8) for NT < 2.5 mm and 96.7% (29/30) for NT ≥ 2.5 mm. Conclusion: The overall detection rate of fetal anomalies including fetal cardiac defects following a specialist scan at 11 + 0 to 13 + 6 weeks' gestation is about 84% and is increased when NT ≥ 2.5 mm. This extends the possibilities of a first‐trimester scan beyond risk assessment for fetal chromosomal defects. In experienced hands with adequate equipment, the majority of severe malformations as well as major CHD may be detected at the end of the first trimester, which offers parents the option of deciding early in pregnancy how to deal with fetuses affected by genetic or structural abnormalities without pressure of time. Copyright © 2006 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Cited by
Verburg, B. O., Steegers, E. A. P., De Ridder, M., Snijders, R. J. M., Smith, E., Hofman, A., Moll, H. A., Jaddoe, V. W. V., & Witteman, J. C. M. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5225 · Cited by 506
Challenges in the diagnosis of fetal non‐chromosomal abnormalities at 11–13 weeks
Syngelaki, A., Chelemen, T., Dagklis, T., Allan, L., & Nicolaides, K. H. (2011) · Prenatal Diagnosis · doi:10.1002/pd.2642 · Cited by 498
Assessment of intracranial translucency (IT) in the detection of spina bifida at the 11–13-week scan
Chaoui, R., Benoit, B., Mitkowska‐Wozniak, H., Heling, K. S., & Nicolaides, K. H. (2009) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7329 · Cited by 321
Rossi, A. C., & Prefumo, F. (2013) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000015 · Cited by 224
Buijtendijk, M. F., Bet, B. B., Leeflang, M. M., Shah, H., Reuvekamp, T., Goring, T., Docter, D., Timmerman, M. G., Dawood, Y., Lugthart, M. A., et al. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014715.pub2 · Cited by 47
Metadata
- Authors
- Becker, R., & Wegner, R. ‐.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2006-03-28
- Volume
- 27
- Issue
- 6
- Pages
- 613-618
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1979967201
- Cited by
- 194
- References
- 1
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.