CoChat

Three‐dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique

Open access
Kalache, K. D., Espinoza, J., Chaiworapongsa, T., Londono, J., Schoen, M. L., Treadwell, M. C., Lee, W., Romero, R. · 2003 · Ultrasound in Obstetrics & Gynecology
Cited by 128

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objectives: This study was designed to compare a conventional multiplanar technique for three‐dimensional (3D) ultrasound measurement of fetal lung volume with a rotational method using VOCAL™ (Virtual Organ Computer‐aided AnaLysis). Methods: Thirty‐two fetuses with a variety of conditions at risk for pulmonary hypoplasia were studied. 3D volume data sets of the fetal lungs were acquired using a commercially available ultrasound system. The right and left lung volumes were calculated separately using VOCAL and the multiplanar technique. The level of agreement between two independent observers in categorizing the 3D volume data set as measurable or non‐measurable was determined. The interobserver and intermethod variabilities were also evaluated for both methods. Results: The intermethod variability was excellent (correlation r = 0.93 and r = 0.96 for the left and right lung, respectively), and there was substantial agreement between the results of both approaches (limits of agreement − 4.4 to 8.9 and − 3.4 to 4.8 mL for the right and left lung, respectively). Fetal lung estimation with VOCAL had a significantly higher interobserver variability than the multiplanar technique. Interobserver agreement in categorizing lung volume data sets as measurable or non‐measurable was lower when VOCAL was used. Conclusion: Fetal lung volume measurements can be undertaken interchangeably using the multiplanar technique or the rotational method with VOCAL. However, the latter was less reproducible (lower degree of agreement and significantly higher interobserver variability) than the former. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.39

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 128

Metadata

Authors
Kalache, K. D., Espinoza, J., Chaiworapongsa, T., Londono, J., Schoen, M. L., Treadwell, M. C., Lee, W., & Romero, R.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2003-02
Volume
21
Issue
2
Pages
111-118
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2021814629
Cited by
128
References
1
FWCI
8.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three‐dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique. https://app.cochat.ai/papers/10.1002/uog.39
The paper
Kalache, K. D., Espinoza, J., Chaiworapongsa, T., Londono, J., Schoen, M. L., Treadwell, M. C., Lee, W., & Romero, R. (2003). Three‐dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.39

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.