Three‐dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objectives: This study was designed to compare a conventional multiplanar technique for three‐dimensional (3D) ultrasound measurement of fetal lung volume with a rotational method using VOCAL™ (Virtual Organ Computer‐aided AnaLysis). Methods: Thirty‐two fetuses with a variety of conditions at risk for pulmonary hypoplasia were studied. 3D volume data sets of the fetal lungs were acquired using a commercially available ultrasound system. The right and left lung volumes were calculated separately using VOCAL and the multiplanar technique. The level of agreement between two independent observers in categorizing the 3D volume data set as measurable or non‐measurable was determined. The interobserver and intermethod variabilities were also evaluated for both methods. Results: The intermethod variability was excellent (correlation r = 0.93 and r = 0.96 for the left and right lung, respectively), and there was substantial agreement between the results of both approaches (limits of agreement − 4.4 to 8.9 and − 3.4 to 4.8 mL for the right and left lung, respectively). Fetal lung estimation with VOCAL had a significantly higher interobserver variability than the multiplanar technique. Interobserver agreement in categorizing lung volume data sets as measurable or non‐measurable was lower when VOCAL was used. Conclusion: Fetal lung volume measurements can be undertaken interchangeably using the multiplanar technique or the rotational method with VOCAL. However, the latter was less reproducible (lower degree of agreement and significantly higher interobserver variability) than the former. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Gorincour, G., Bouvenot, J., Mourot, M. G., Sonigo, P., Chaumoitre, K., Garel, C., Guibaud, L., Rypens, F., Avni, F., Cassart, M., et al. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2618 · Cited by 178
Cheong, K. B., Leung, K. Y., Li, T. K. T., Chan, H. Y., Lee, Y. P., & Tang, M. H. Y. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7609 · Cited by 45
Prendergast, M., Rafferty, G., Davenport, M., Persico, N., Jani, J., Nicolaides, K., & Greenough, A. (2011) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2010.02841.x · Cited by 30
Sonographic development of the normal foetal thorax and abdomen across gestation
Blaas, H. K., & Eik‐Nes, S. H. (2008) · Prenatal Diagnosis · doi:10.1002/pd.1963 · Cited by 27
“The echogenicity of the lungs usually appears somewhat brighter than the echogenicity of the liver; this becomes clearer by applying harmonic imaging (Kalache et al., 2003) (Figure 6(A) and (B)).”
Background
Metadata
- Authors
- Kalache, K. D., Espinoza, J., Chaiworapongsa, T., Londono, J., Schoen, M. L., Treadwell, M. C., Lee, W., & Romero, R.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2003-02
- Volume
- 21
- Issue
- 2
- Pages
- 111-118
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2021814629
- Cited by
- 128
- References
- 1
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three‐dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique. https://app.cochat.ai/papers/10.1002/uog.39
- The paper
- Kalache, K. D., Espinoza, J., Chaiworapongsa, T., Londono, J., Schoen, M. L., Treadwell, M. C., Lee, W., & Romero, R. (2003). Three‐dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.39
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.