The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A mixture model of nuchal translucency thickness in screening for chromosomal defects
Open accessAbstract
Objective: Fetal nuchal translucency (NT) thickness increases with crown–rump length (CRL). In screening for chromosomal defects patient‐specific risks are derived by multiplying the a priori maternal age‐related risk by a likelihood ratio, determined from the deviation of the measured NT from the expected median. To quantify this deviation the measured NT is either subtracted (delta NT) or divided by the expected median (multiple of the median method, MoM). This study examines the validity of these methods. Methods: NT was prospectively measured at 11 + 0 to 13 + 6 weeks in screening for chromosomal defects. The distribution of NT in euploid and chromosomally abnormal fetuses was examined. Results: There were 37 078 normal pregnancies and 264 with trisomy 21, 81 with trisomy 18, 38 with trisomy 13 and 27 with Turner syndrome. We found that firstly, contrary to the assumption underlying the delta NT method, the distribution of delta NT changes with CRL and secondly, contrary to the assumption underlying the MoM method the distribution of NT was not Gaussian. Fetal NT followed two distributions, one that was dependent on CRL and one that was independent of CRL. The distribution in which NT increases with CRL was observed in about 95% of euploid fetuses, 5% with trisomy 21, 30% with trisomy 18, 15% with trisomy 13 and 10% with Turner syndrome. The median CRL‐independent NT was 2.0 mm for the euploid group and 3.4, 5.5, 4.0 and 7.8 mm for trisomies 21, 18, 13 and Turner syndrome, respectively. Conclusions: The NT thickness in chromosomally normal and abnormal fetuses follows a mixture of a gestation‐dependent and gestation‐independent distribution. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating non-randomised intervention studies
Deeks, J., Dinnes, J., D'Amico, R., Sowden, A., Sakarovitch, C., Song, F., Petticrew, M., & Altman, D. (2003) · Health Technology Assessment · doi:10.3310/hta7270 · Cited by 2,907
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
III. Contributions to the mathematical theory of evolution
Pearson, K. (1894) · Philosophical Transactions of the Royal Society of London. (A.) · doi:10.1098/rsta.1894.0003 · Cited by 1,550
Nicolaides, K. H., Azar, G., Byrne, D., Mansur, C., & Marks, K. (1992) · BMJ · doi:10.1136/bmj.304.6831.867 · Cited by 1,056
Self-citationA Language and Program for Complex Bayesian Modelling
Gilks, W. R., Thomas, A., & Spiegelhalter, D. J. (1994) · The Statistician · doi:10.2307/2348941 · Cited by 653
Nuchal translucency and other first-trimester sonographic markers of chromosomal abnormalities
Nicolaides, K. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.090 · Cited by 626
Self-citationHyett, J., Perdu, M., Sharland, G., Snijders, R., & Nicolaides, K. H. (1999) · BMJ · doi:10.1136/bmj.318.7176.81 · Cited by 611
Self-citationCUCKLE, H. S., WALD, N. J., & THOMPSON, S. G. (1987) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1987.tb03115.x · Cited by 604
Wald, N. J., Rodeck, C., Hackshaw, A. K., Walters, J., Chitty, L., & Mackinson, A. M. (2003) · Health Technology Assessment · doi:10.3310/hta7110 · Cited by 585
Increased nuchal translucency with normal karyotype
Souka, A. P., von Kaisenberg, C. S., Hyett, J. A., Sonek, J. D., & Nicolaides, K. H. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.093 · Cited by 517
Self-citationMaternal Age and Gestational Age-Specific Risk for Chromosomal Defects
Snijders, R. J. M., Sebire, N. J., & Nicolaides, K. H. (1995) · Fetal Diagnosis and Therapy · doi:10.1159/000264259 · Cited by 277
Self-citationRelation between increased fetal nuchal translucency thickness and chromosomal defects
Kagan, K. O., Avgidou, K., Molina, F. S., Gajewska, K., & Nicolaides, K. H. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000191301.63871.c6 · Cited by 171
Self-citationProspective first-trimester screening for trisomy 21 in 30,564 pregnancies
Avgidou, K., Papageorghiou, A., Bindra, R., Spencer, K., & Nicolaides, K. H. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2005.03.021 · Cited by 162
Self-citationLetter. Correct estimation of parameters for ultrasound nuchal translucency screening
Nicolaides, K. H., Snijders, R. J. M., & Cuckle, H. (1998) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199805)18:5<519::aid-pd398>3.0.co;2-u · Cited by 162
Self-citationCorrect estimation of parameters for ultrasound nuchal translucency screening.
Nicolaides, K. H., Snijders, R. J. M., & Cuckle, H. (1998) · PubMed · Cited by 148
Self-citationSpencer, K., Bindra, R., Nix, A. B. J., Heath, V., & Nicolaides, K. H. (2003) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.186 · Cited by 119
Self-citationCollagen type VI gene expression in the skin of trisomy 21 fetuses*1
VONKAISENBERG, C. (1998) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(97)00697-2 · Cited by 97
von Kaisenberg, C. S., Krenn, V., Ludwig, M. Z., Nicolaides, K. H., & Brand‐Saberi, B. (1998) · Anatomy and Embryology · doi:10.1007/s004290050123 · Cited by 94
Self-citationCystic Hygromas, Nuchal Edema, and Nuchal Translucency at 11–14 Weeks of Gestation
Molina, F. S., Avgidou, K., Kagan, K. O., Poggi, S., & Nicolaides, K. H. (2006) · Obstetrics and Gynecology · doi:10.1097/01.aog.0000201979.23031.32 · Cited by 93
Self-citationLymphatic vessel hypoplasia in fetuses with Turner syndrome
von Kaisenberg, C. S. (1999) · Human Reproduction · doi:10.1093/humrep/14.3.823 · Cited by 86
Bray, I., & Wright, D. E. (1998) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(1998100)18:10<1045::aid-pd403>3.0.co;2-r · Cited by 41
Self-citation
Cited by
Screening for fetal aneuploidies at 11 to 13 weeks
Nicolaides, K. H. (2011) · Prenatal Diagnosis · doi:10.1002/pd.2637 · Cited by 642
Self-citationChallenges in the diagnosis of fetal non‐chromosomal abnormalities at 11–13 weeks
Syngelaki, A., Chelemen, T., Dagklis, T., Allan, L., & Nicolaides, K. H. (2011) · Prenatal Diagnosis · doi:10.1002/pd.2642 · Cited by 498
Self-citationAshoor, G., Syngelaki, A., Poon, L. C. Y., Rezende, J. C., & Nicolaides, K. H. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12331 · Cited by 396
Self-citationKagan, K. O., Wright, D., Baker, A., Sahota, D., & Nicolaides, K. H. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5331 · Cited by 378
Self-citationAshoor, G., Syngelaki, A., Wagner, M., Birdir, C., & Nicolaides, K. H. (2012) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2012.01.029 · Cited by 325
Self-citation
Metadata
- Authors
- Wright, D., Kagan, K. O., Molina, F. S., Gazzoni, A., & Nicolaides, K. H.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2008-03-28
- Volume
- 31
- Issue
- 4
- Pages
- 376-383
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2122622674
- Cited by
- 257
- References
- 21
- FWCI
- 20.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.