ISUOG consensus statement: what constitutes a fetal echocardiogram?
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
In 2006 the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) published practice guidelines for the sonographic screening of congenital heart disease (CHD) during the second trimester of pregnancy1. This document described two levels for screening low-risk fetuses for heart anomalies. Firstly, a 'basic' scan should be performed by analyzing a four-chamber view of the fetal heart. Secondly, an 'extended-basic' scan further examines the size and relationships of both arterial outflow tracts. The term 'fetal echocardiogram' was also mentioned as a more detailed sonographic evaluation to be performed by specialists in the prenatal diagnosis of CHD. Although common indications and imaging techniques were briefly discussed, it was thought important to further explain how this advanced diagnostic procedure differs from the basic and extended-basic cardiac screening examinations. A Fetal Echocardiography Task Force was subsequently asked to develop a standard description of 'what constitutes a fetal echocardiogram'. Our original goal was to develop guidelines for a detailed examination of the fetal heart that were based on the literature and a consensus opinion of an expert panel. However, we soon realized that this project was quite different from developing minimum practice guidelines for fetal cardiac screening. There are several imaging modalities that can be used to evaluate fetal heart anomalies, ranging from M-mode techniques and color Doppler sonography to the use of four-dimensional (4D) ultrasonography with spatiotemporal image correlation (STIC). Consequently, our original efforts to develop a minimum practice guideline for fetal echocardiography evolved into a consensus statement that covers the following topics: guidance about timing of and indications for fetal echocardiography; a definition of what constitutes a fetal echocardiogram; a description of imaging modalities for fetal echocardiography; the importance of multidisciplinary collaboration; and documentation of diagnostic findings and conclusions. Fetal echocardiography can be performed at any time during the second trimester when cardiac anatomical details can be satisfactorily visualized. For example, a mother who is at a slightly increased risk for CHD—e.g. 2% against a background rate of 0.8%—should be electively scheduled for a detailed cardiac scan at some time between 18 and 22 weeks' menstrual age. These include mothers with a family history of CHD, maternal diabetes or exposure to teratogenic drugs, and fetuses that have had an increased nuchal translucency thickness measurement. Fetal cardiac abnormalities may occur in association with extracardiac anomalies and therefore a detailed cardiac scan may be indicated when such anomalies are detected5-7. A mother who is particularly anxious because of a family history, perhaps loss of a previous child for example, or where the nuchal translucency measurement is ≥ 3.5 mm, may be offered a scan at or before 14 weeks' gestation, with a follow-up scan at 20–22 weeks8. If a fetus is suspected of having CHD at any scan, it should be seen as soon as possible, regardless of menstrual age. Others have suggested using a fetal echocardiogram as a component of the genetic sonogram, to evaluate fetuses at risk for chromosome abnormalities9, 10. The detection rate of structural heart anomalies will be higher with fetal echocardiography than with screening examinations. Women with recognized increased risks for fetal cardiac anomalies should be offered a more detailed scan. Risk factors for fetal cardiac anomalies can be categorized as fetal or maternal in origin. Some of the more common indications for fetal echocardiography are summarized in Table 1. Acquired cardiac lesions that become apparent later in life, even those of genetic origin such as Marfan's syndrome and hypertrophic subaortic stenosis, are not generally detectable by prenatal ultrasonography. Many experienced healthcare professionals, whether they are midwives, sonographers, obstetricians, perinatologists or radiologists, can evaluate the fetal heart with a high degree of diagnostic accuracy during an obstetric ultrasound evaluation. The echocardiogram can be individualized, depending on the nature of the suspected cardiac lesion. As a minimum, it involves a thorough examination of the four-chamber view, both arterial outflow tracts, three vessels and trachea view, and an assessment of pulmonary venous return11-14. The examiner should confirm anatomical relationships and functional flow characteristics through a systematic analysis of the following areas: cardiac axis and situs ventricular morphology pericardial effusions venous-atrial, atrioventricular and ventriculoarterial connections of the heart size and relationships of the left and right ventricular outflow tracts ductal and aortic arches interventricular septum atrial septum, atrial chamber size, and foramen ovale atrioventricular and semilunar valves flow a
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of Transposition of the Great Arteries in Fetuses Reduces Neonatal Morbidity and Mortality
Bonnet, D., Coltri, A., Butera, G., Fermont, L., Le Bidois, J., Kachaner, J., & Sidi, D. (1999) · Circulation · doi:10.1161/01.cir.99.7.916 · Cited by 760
Nelson, S. W. (1969) · The Knowledge Bank (The Ohio State University) · Cited by 367
Spatio‐temporal image correlation (STIC): new technology for evaluation of the fetal heart
DeVore, G. R., Falkensammer, P., Sklansky, M. S., & Platt, L. D. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.217 · Cited by 362
Self-citationDevelopment of Z‐scores for fetal cardiac dimensions from echocardiography
Schneider, C., McCrindle, B. W., Carvalho, J. S., Hornberger, L. K., McCarthy, K. P., & Daubeney, P. E. F. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2597 · Cited by 314
Self-citationCongenital Heart Defects: Natural Course and In Utero Development
Yagel, S., Weissman, A., Rotstein, Z., Manor, M., Hegesh, J., Anteby, E., Lipitz, S., & Achiron, R. (1997) · Circulation · doi:10.1161/01.cir.96.2.550 · Cited by 311
Self-citationYagel, S., Cohen, S. M., & Achiron, R. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00414.x · Cited by 299
Self-citationThe three vessels and trachea view (3VT) in fetal cardiac scanning
Yagel, S., Arbel, R., Anteby, E. Y., Raveh, D., & Achiron, R. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2002.00801.x · Cited by 261
Self-citation(2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2677 · Cited by 256
Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation
Gonçalves, L. F., Lee, W., Chaiworapongsa, T., Espinoza, J., Schoen, M. L., Falkensammer, P., Treadwell, M., & Romero, R. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(03)00913-x · Cited by 233
Self-citationChaoui, R., Hoffmann, J., & Heling, K. S. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1075 · Cited by 229
Self-citation
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Self-citationISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Self-citationISUOG Practice Guidelines (updated): fetal cardiac screening
Carvalho, J. S., Axt‐Fliedner, R., Chaoui, R., Copel, J. A., Cuneo, B. F., Goff, D., Gordin Kopylov, L., Hecher, K., Lee, W., Moon‐Grady, A. J., et al. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26224 · Cited by 246
Self-citationUltrasound assessment of fetal cardiac function
Crispi, F., Valenzuela‐Alcaraz, B., Cruz‐Lemini, M., & Gratacós, E. (2013) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/j.2205-0140.2013.tb00242.x · Cited by 70
Nagata, H., Glick, L., Lougheed, J., Grattan, M., Mondal, T., Thakur, V., Schwartz, S. M., & Jaeggi, E. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.01.010 · Cited by 46
Metadata
- Authors
- Lee, W., Allan, L., Carvalho, J. S., Chaoui, R., Copel, J., Devore, G., Hecher, K., Munoz, H., Nelson, T., Paladini, D., & Yagel, S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 32
- Issue
- 2
- Pages
- 239-242
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2118084462
- Cited by
- 185
- References
- 22
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.