Intraobserver and interobserver reliability of automated antral follicle counts made using three‐dimensional ultrasound and SonoAVC
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objective: To assess the reliability of automated measurements of the total antral follicle count (AFC) made using Sono‐Automatic Volume Count (SonoAVC), and to compare these to two‐dimensional (2D) and manual three‐dimensional (3D) techniques. Methods: Fifty‐five subjects aged under 40 years who had 3D transvaginal ultrasound examination in the early follicular phase of their menstrual cycle were prospectively recruited. 3D datasets were acquired and subsequently analyzed. The total AFC (2–10 mm antral follicles) was calculated by two observers using three independent methods: 2D real‐time equivalent (2D‐RTE), 3D manual multiplanar view (3D‐MPV), and SonoAVC. For measurements made using SonoAVC, the initial automated count (sAVC‐AA) was recorded and postprocessing (sAVC‐PP) then applied to identify follicles that had been missed or incorrectly included. Intraclass correlation and limits of agreement were used to evaluate the methods. Results: The intra‐ and interobserver reliability of measurements of total AFC was best with SonoAVC with postprocessing followed by 3D‐MPV and 2D‐RTE. The initial count calculated by sAVC‐AA missed follicles and this was reflected in the significantly lower mean total AFC (6.51 ± 4.79) than that made after postprocessing techniques (sAVC‐PP, 18.42 ± 10.53, P < 0.001; 3D‐MPV, 19.38 ± 10.85, P < 0.001; and 2D‐RTE, 19.26 ± 10.55, P < 0.001). The mean total AFC became more comparable with postprocessing (sAVC‐PP) but still remained significantly lower than counts made with 2D‐RTE and 3D‐MPV (P < 0.05). Conclusion: SonoAVC with postprocessing is a reliable method for measuring total AFC. It takes longer to perform, because of the need for postprocessing, and obtains values that are lower than those obtained by the 2D and 3D‐MPV techniques. However, the AFC obtained by sAVC‐PP is likely to be lower because this method measures and color codes each follicle preventing recounting. Copyright © 2009 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Evaluation of a clinical test. I: Assessment of reliability
Kha, K. S., & Chien, P. F. W. (2001) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2001.00150.x · Cited by 135
Cited by
The polycystic ovary syndrome: a position statement from the European Society of Endocrinology
Conway, G., Dewailly, D., Diamanti-Kandarakis, E., Escobar-Morreale, H. F., Franks, S., Gambineri, A., Kelestimur, F., Macut, D., Micic, D., Pasquali, R., et al. (2014) · European Journal of Endocrinology · doi:10.1530/eje-14-0253 · Cited by 676
Dewailly, D., Lujan, M. E., Carmina, E., Cedars, M. I., Laven, J., Norman, R. J., & Escobar-Morreale, H. F. (2014) · Human Reproduction Update · doi:10.1093/humupd/dmt061 · Cited by 551
van Disseldorp, J., Lambalk, C. B., Kwee, J., Looman, C. W. N., Eijkemans, M. J. C., Fauser, B. C., & Broekmans, F. J. (2010) · Human Reproduction · doi:10.1093/humrep/dep366 · Cited by 347
Assessing ovarian response: antral follicle count versus anti-Müllerian hormone
Fleming, R., Seifer, D. B., Frattarelli, J. L., & Ruman, J. (2015) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2015.06.015 · Cited by 291
Iliodromiti, S., Anderson, R. A., & Nelson, S. M. (2015) · Human Reproduction Update · doi:10.1093/humupd/dmu062 · Cited by 260
Metadata
- Authors
- Deb, S., Jayaprakasan, K., Campbell, B. K., Clewes, J. S., Johnson, I. R., & Raine‐Fenning, N. J.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2009-02-11
- Volume
- 33
- Issue
- 4
- Pages
- 477-483
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2034421018
- Cited by
- 102
- References
- 6
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraobserver and interobserver reliability of automated antral follicle counts made using three‐dimensional ultrasound and SonoAVC. https://app.cochat.ai/papers/10.1002/uog.6310
- The paper
- Deb, S., Jayaprakasan, K., Campbell, B. K., Clewes, J. S., Johnson, I. R., & Raine‐Fenning, N. J. (2009). Intraobserver and interobserver reliability of automated antral follicle counts made using three‐dimensional ultrasound and SonoAVC. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.6310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.