CoChat

Intraobserver and interobserver reliability of automated antral follicle counts made using three‐dimensional ultrasound and SonoAVC

Open access
Deb, S., Jayaprakasan, K., Campbell, B. K., Clewes, J. S., Johnson, I. R., Raine‐Fenning, N. J. · 2009 · Ultrasound in Obstetrics & Gynecology
Cited by 102

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objective: To assess the reliability of automated measurements of the total antral follicle count (AFC) made using Sono‐Automatic Volume Count (SonoAVC), and to compare these to two‐dimensional (2D) and manual three‐dimensional (3D) techniques. Methods: Fifty‐five subjects aged under 40 years who had 3D transvaginal ultrasound examination in the early follicular phase of their menstrual cycle were prospectively recruited. 3D datasets were acquired and subsequently analyzed. The total AFC (2–10 mm antral follicles) was calculated by two observers using three independent methods: 2D real‐time equivalent (2D‐RTE), 3D manual multiplanar view (3D‐MPV), and SonoAVC. For measurements made using SonoAVC, the initial automated count (sAVC‐AA) was recorded and postprocessing (sAVC‐PP) then applied to identify follicles that had been missed or incorrectly included. Intraclass correlation and limits of agreement were used to evaluate the methods. Results: The intra‐ and interobserver reliability of measurements of total AFC was best with SonoAVC with postprocessing followed by 3D‐MPV and 2D‐RTE. The initial count calculated by sAVC‐AA missed follicles and this was reflected in the significantly lower mean total AFC (6.51 ± 4.79) than that made after postprocessing techniques (sAVC‐PP, 18.42 ± 10.53, P < 0.001; 3D‐MPV, 19.38 ± 10.85, P < 0.001; and 2D‐RTE, 19.26 ± 10.55, P < 0.001). The mean total AFC became more comparable with postprocessing (sAVC‐PP) but still remained significantly lower than counts made with 2D‐RTE and 3D‐MPV (P < 0.05). Conclusion: SonoAVC with postprocessing is a reliable method for measuring total AFC. It takes longer to perform, because of the need for postprocessing, and obtains values that are lower than those obtained by the 2D and 3D‐MPV techniques. However, the AFC obtained by sAVC‐PP is likely to be lower because this method measures and color codes each follicle preventing recounting. Copyright © 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.6310

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Deb, S., Jayaprakasan, K., Campbell, B. K., Clewes, J. S., Johnson, I. R., & Raine‐Fenning, N. J.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2009-02-11
Volume
33
Issue
4
Pages
477-483
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2034421018
Cited by
102
References
6
FWCI
7.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.