Spatio‐temporal image correlation (STIC): a new tool for the prenatal screening of congenital heart defects
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objective: To assess the feasibility and capability of STIC acquisition, performed by a general obstetrician performing antenatal ultrasound, to visualize fetal cardiac structures in women undergoing routine obstetric ultrasound examination, in order to obtain information to confirm normality of the fetal heart during intrauterine life. Methods: This was a prospective study of one hundred fetuses with echocardiographically confirmed normal hearts and no extracardiac anomalies with gestational ages ranging between 18 and 37 weeks. A general obstetrician was invited to acquire the STIC volumes. The four‐chamber view was obtained as a starting point. A standard 7.5‐s acquisition time and 30° angle of acquisition were used and the resulting STIC was stored for later offline analysis by a fetal echocardiologist. For each patient, the stored STIC data were first evaluated by sweeping from the initial acquisition plane, in the caudal direction and then cranially, zooming, slowing or stopping the cardiac motion to visualize views and structures. If a structure or view was rated as inadequate or not identifiable, a multiplanar three‐dimensional (3D) examination of the STIC volume was taken in order to try to visualize it adequately. The rates obtained using just the STIC sweeps were compared independently, and then the 3D multiplanar study was added. Results: STIC acquisition was possible in all cases. The mean time required for STIC acquisition was 7.5 min. A complete cardiac examination according to the set criteria was achieved in 94.2% (95% confidence interval (CI), 90–99) of cases. We obtained a 94.2% success rate of visualizing different structures and views of the fetal heart using the STIC sweep alone (95% CI, 90–99) and 96.2% adding 3D multiplanar examination (95% CI, 92–100). Conclusion: STIC acquisition of the fetal heart is feasible with high success rates in visualization of the principal connections. The STIC data acquired by a general obstetrician can subsequently be used by a fetal echocardiologist for prenatal confirmation of normal cardiac structure or exclusion of major cardiac malformations. Copyright © 2003 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence of congenital heart disease: I. Postnatal incidence
Hoffman, J. I. E. (1995) · Pediatric Cardiology · doi:10.1007/bf00801907 · Cited by 786 · cited 1×
“For each patient, cardiac structures and views were rated as follows: (1) not identifiable, (2) identifiable but inadequate for diagnosis and (3) adequate for diagnosis.”
Detection of Transposition of the Great Arteries in Fetuses Reduces Neonatal Morbidity and Mortality
Bonnet, D., Coltri, A., Butera, G., Fermont, L., Le Bidois, J., Kachaner, J., & Sidi, D. (1999) · Circulation · doi:10.1161/01.cir.99.7.916 · Cited by 760
Congenital heart disease in a cohort of 19,502 births with long-term follow-up
Hoffman, J. I. E., & Christianson, R. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90635-5 · Cited by 548
Prenatal diagnosis of coarctation of the aorta improves survival and reduces morbidity: Table 1
Franklin, O., Burch, M., Manning, N., Sleeman, K., Gould, S., & Archer, N. (2002) · Heart · doi:10.1136/heart.87.1.67 · Cited by 421
Incidence of congenital heart disease: II. Prenatal incidence
Hoffman, J. I. E. (1995) · Pediatric Cardiology · doi:10.1007/bf00794186 · Cited by 397 · cited 1×
“For each patient, cardiac structures and views were rated as follows: (1) not identifiable, (2) identifiable but inadequate for diagnosis and (3) adequate for diagnosis.”
Mahle, W. T., Clancy, R. R., McGaurn, S. P., Goin, J. E., & Clark, B. J. (2001) · Pediatrics · doi:10.1542/peds.107.6.1277 · Cited by 375
Garne, E., Stoll, C., & Clementi, M. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00385.x · Cited by 346
Kumar, R. K., Newburger, J. W., Gauvreau, K., Kamenir, S. A., & Hornberger, L. K. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00172-1 · Cited by 305
Yagel, S., Cohen, S. M., & Achiron, R. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00414.x · Cited by 299
Ferencz, C., Neill, C. A., Boughman, J. A., Rubin, J. D., Brenner, J. I., & Perry, L. W. (1989) · The Journal of Pediatrics · doi:10.1016/s0022-3476(89)80605-5 · Cited by 292
The three vessels and trachea view (3VT) in fetal cardiac scanning
Yagel, S., Arbel, R., Anteby, E. Y., Raveh, D., & Achiron, R. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2002.00801.x · Cited by 261
Yoo, S. ‐., Lee, Y. ‐., Kim, E. S., Ryu, H. M., Kim, M. Y., Choi, H. ‐., Cho, K. S., & Kim, A. (1997) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1997.09030173.x · Cited by 260
Allan, L. D., Hornberger, L. K., & Sharland, G. K. (2000) · Cited by 223
SHARLAND, G. K., & ALLAN, L. D. (1992) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1992.tb14503.x · Cited by 207
Efficacy of Routine Fetal Ultrasound Screening for Congenital Heart Disease in Normal Pregnancy
Buskens, E., Grobbee, D. E., Frohn-Mulder, I. M. E., Stewart, P. A., Juttmann, R. E., Wladimiroff, J. W., & Hess, J. (1996) · Circulation · doi:10.1161/01.cir.94.1.67 · Cited by 181
Nelson, T. R., Pretorius, D. H., Sklansky, M., & Hagen-Ansert, S. (1996) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1996.15.1.1 · Cited by 172
Prenatal diagnosis of congenital heart disease affects preoperative acidosis in the newborn patient
Verheijen, P. M., Lisowski, L. A., Stoutenbeek, P., Hitchcock, J. F., Brenner, J. I., Copel, J. A., Kleinman, C. S., Meijboom, E. J., & Bennink, G. B. W. E. (2001) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.112825 · Cited by 162
Isolated major congenital heart disease
Ld, A., Benacerraf, B. R., Copel, J. A., Carvalho, J. S., Chaoui, R., Eik‐Nes, S. H., Tegnander, E., Gembruch, U., Huhta, J. C., Pilu, G., et al. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2001.00439.x · Cited by 134
Evaluation of prenatal diagnosis of congenital heart disease
Stoll, C., Alembik, Y., Dott, B., Roth, P. M., & De Geeter, B. (1993) · Prenatal Diagnosis · doi:10.1002/pd.1970130606 · Cited by 102
Three-dimensional ultrasonography of normal fetal heart: comparison with two-dimensional imaging.
Levental, M., Pretorius, D. H., Sklansky, M., Budorick, N. E., Nelson, T. R., & Lou, K. V. (1998) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1998.17.6.341 · Cited by 82
Screening for congenital heart disease with the four-chamber view of the fetal heart
Vergani, P., Mariani, S., Ghidini, A., Schiavina, R., Cavallone, M., Locatelli, A., Strobelt, N., & Cerruti, P. (1992) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(12)80027-5 · Cited by 81
Sklansky, M., Nelson, T. R., & Pretorius, D. H. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00448-7 · Cited by 73
Detailed three‐dimensional fetal echocardiography facilitated by an Internet link
Michailidis, G. D., Simpson, J. M., Karidas, C., & Economides, D. L. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00520.x · Cited by 67
Meyer‐Wittkopf, M., Cooper, S., Vaughan, J., & Sholler, G. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00429.x · Cited by 66
Zosmer, N., Jurkovic, D., Jauniaux, E. R. M., Gruboeck, K., Lees, C. C., & Campbell, S. C. (1996) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1996.15.1.25 · Cited by 63
Sequential segmental approach to fetal congenital heart disease
Yoo, S., Lee, Y. H., Cho, K. S., & Kim, D.-Y. (1999) · Cardiology in the Young · doi:10.1017/s1047951100005266 · Cited by 61
Young, I. D., & Clarke, M. (1987) · BMJ · doi:10.1136/bmj.295.6590.89 · Cited by 59
Meyer-Wittkopf, M., Rappe, N., Sierra, F., Barth, H., & Schmidt, S. (2000) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2000.00108.x · Cited by 53
Tegnander, E., Eik‐Nes, S. H., & Linker, D. T. (1994) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1994.04010024.x · Cited by 52
Prenatal detection of ductal‐dependent congenital heart disease: how can things be made easier?
Viñals, F., Tapia, J., & Giuliano, A. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2002.00651.x · Cited by 25
Self-citationFetal echo cardiography: the state of the art of the state of the heart
Chaoui, R. (2001) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2001.00413.x · Cited by 23
(1997) · doi:10.1002/(sici)1097-0223(199710)17:10<901::aid-pd171>3.0.co;2-z
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Chaoui, R., Hoffmann, J., & Heling, K. S. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1075 · Cited by 229
3D and 4D ultrasound in fetal cardiac scanning: a new look at the fetal heart
Yagel, S., Cohen, S. M., Shapiro, I., & Valsky, D. V. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.3912 · Cited by 174
Viñals, F., Mandujano, L., Vargas, G., & Giuliano, A. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1796 · Cited by 147
Yeo, L., & Romero, R. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12563 · Cited by 110
Metadata
- Authors
- Viñals, F., Poblete, P., & Giuliano, A.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2003-09-29
- Volume
- 22
- Issue
- 4
- Pages
- 388-394
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1976534591
- Cited by
- 187
- References
- 32
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.