Simultaneous Analysis of the Majority of Low-Molecular-Weight, Redox-Active Compounds from Mitochondria
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Studies of the interaction between oxidative stress and mitochondrial dysfunction are complicated by analytical limitations, especially the need to assess multiple parameters in relatively small samples. We have addressed this problem by developing a methodology for the simultaneous analysis of the majority of low-molecular-weight, redox-active compounds from mitochondria using HPLC separations followed by coulometric array detection. The method described should also be applicable for the study of redox-active compounds in other subcellular organelles as well as in intact cells and tissues. The protocol described enables simultaneous measurement of antioxidants (e.g., tocopherols, ascorbate, lipoates, uric acid, and glutathione), markers of oxidative stress (e.g., o-tyrosine, m-tyrosine, nitrotyrosine, dityrosine, glutathione disulfide, and 8-hydroxydeoxyguanosine) as well as other metabolites (e.g., purines and indoles). In all, ca. 600 redox active compounds can be detected, most with a limit of detection of approximately 5 pg on column. Results, including analytical parameters, from a study of liver mitochondria from control and diabetic rats are presented to demonstrate utility of this methodology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hensley, K., Maidt, M. L., Pye, Q. N., Stewart, C. A., Wack, M., Tabatabaie, T., & Floyd, R. A. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2281 · Cited by 89
Cited by
Measuring the metabolome: current analytical technologies
Dunn, W. B., Bailey, N. J. C., & Johnson, H. E. (2005) · The Analyst · doi:10.1039/b418288j · Cited by 924
Metabolomics and systems biology: making sense of the soup
KELL, D. (2004) · Current Opinion in Microbiology · doi:10.1016/j.mib.2004.04.012 · Cited by 529
“Coulometry is another sensitive and somewhat underutilised detection method; Matson and colleagues give an example in which some 600 metabolites could be discriminated [27].”
MethodQueval, G., & Noctor, G. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.005 · Cited by 468
Unintended effects and their detection in genetically modified crops
Cellini, F., Chesson, A., Colquhoun, I., Constable, A., Davies, H. V., Engel, K. H., Gatehouse, A. M. R., Kärenlampi, S., Kok, E. J., Leguay, J.-J., et al. (2004) · Food and Chemical Toxicology · doi:10.1016/j.fct.2004.02.003 · Cited by 397
“Simultaneous analysis of many redox active metabolites in mitochondria (Kristal et al., 1998) and serum (Vigneau-Callahan et al., 2001) has been carried out by HPLC coupled with Coulometric array detection , a method that offers very high sensitivity.”
MethodMetabolomics: from pattern recognition to biological interpretation
Weckwerth, W., & Morgenthal, K. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03609-3 · Cited by 298
Metadata
- Authors
- Kristal, B. S., Vigneau-Callahan, K. E., & Matson, W. R.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 1998-10
- Volume
- 263
- Issue
- 1
- Pages
- 18-25
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W2021727217
- Cited by
- 58
- References
- 1
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.