Measurements of Restricted Diffusion Using an Oscillating Gradient Spin-Echo Sequence
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An oscillating gradient spin-echo (OGSE) pulse sequence was used to measure the apparent diffusion coefficient (D(app)) of water in the short diffusion time regime in the presence of restrictions. The diffusion coefficients of water in a simple water sample and a water and oil mixture were measured to be the same for different periods of the gradient oscillation, as expected when there are no restriction effects. The D(app) of water in the spaces between closely packed beads was also measured as a function of the gradient oscillation periods in the range 11 to 80 ms. The D(app) of water in restricted systems varies with the period of the gradient oscillation and the dispersion depends on the scale of the restriction. For a sample of packed beads of diameter 9.1 +/- 0.7 microm, the pore surface-to-volume ratio was estimated experimentally by this method to be 1.3 +/- 0.1 microm(-1), corresponding to a mean pore diameter of 6.4 +/- 0.7 microm. A Monte Carlo computer simulation of the NMR OGSE signal from the spins diffusing in a system of compartments was also implemented and the D(app) demonstrated similar behavior with gradient oscillation periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Cited by
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
Does, M. D., Parsons, E. C., & Gore, J. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10385 · Cited by 246
Self-citationThe Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2009) · Diffusion MRI · doi:10.1016/b978-0-12-374709-9.00006-7 · Cited by 217
Probing mouse brain microstructure using oscillating gradient diffusion MRI
Aggarwal, M., Jones, M. V., Calabresi, P. A., Mori, S., & Zhang, J. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22981 · Cited by 117
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2014) · Diffusion MRI · doi:10.1016/b978-0-12-396460-1.00008-1 · Cited by 66
Metadata
- Authors
- Schachter, M., Does, M. D., Anderson, A. W., & Gore, J. C.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2000-12
- Volume
- 147
- Issue
- 2
- Pages
- 232-237
- ISSN
- 1090-7807 (ISSN-L)
- OpenAlex
- W2024707605
- Cited by
- 126
- References
- 2
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements of Restricted Diffusion Using an Oscillating Gradient Spin-Echo Sequence. https://app.cochat.ai/papers/10.1006/jmre.2000.2203
- The paper
- Schachter, M., Does, M. D., Anderson, A. W., & Gore, J. C. (2000). Measurements of Restricted Diffusion Using an Oscillating Gradient Spin-Echo Sequence. Journal of Magnetic Resonance. https://doi.org/10.1006/jmre.2000.2203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.