Functional MRI of Human Brain during Breath Holding by BOLD and FAIR Techniques
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BOLD (blood oxygenation level-dependent) and FAIR (flow-sensitive alternating inversion recovery) imaging techniques were used to investigate the oxygenation and hemodynamic responses of human brain during repeated challenges of breath holding and prolonged single breath holding. The effects of different breathing techniques on BOLD and FAIR image contrasts were carefully examined. With a periodic breath-holding paradigm of 30 s, global changes in gray matter were observable both in T*2-weighted and FAIR images. T*2-weighted images showed 1-4% relative signal intensity increases, while FAIR images demonstrated relative cerebral blood flow (CBF) increase up to 30-70%. The activated pixels depicted in FAIR images were about three times less than those seen in T*2-weighted images. With prolonged breath holding, it was observed that signal intensities in T*2-weighted and FAIR images were dependent on the breathing techniques used. Breath holding after expiration gave rise to immediate signal intensity increases in T*2-weighted and FAIR images, whereas breath holding performed after deep inspiration signals showed a biphasic change both in flow and T*2-weighted. T*2-weighted and FAIR signals showed a transient decrease before rising above the baseline level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827
Sex Dependency of Cerebrovascular CO 2 Reactivity in Normal Subjects
Kastrup, A., Thomas, C., Hartmann, C., & Schabet, M. (1997) · Stroke · doi:10.1161/01.str.28.12.2353 · Cited by 127
Self-citation
Cited by
Murphy, K., Birn, R. M., Handwerker, D. A., Jones, T. B., & Bandettini, P. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.036 · Cited by 2,387
“The global signal was modulated using a breath hold task that produces a large global BOLD signal increase (Kwong et al., 1992; Li et al., 1999).”
Birn, R. M., Diamond, J. B., Smith, M. A., & Bandettini, P. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.048 · Cited by 1,358
Birn, R. M., Smith, M. A., Jones, T. B., & Bandettini, P. A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.059 · Cited by 645
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
“Although this effect can be clearly observed in response to a hypercapnic or breath-holding challenge (Bright et al., 2009; Bulte et al., 2012; Kastrup et al., 1998, 1999a, 1999b; Li et al., 1999), it also naturally occurs during normal breathing where subtle variations in the depth and rate of breathing cause small f…”
The Effect of Flavanol-rich Cocoa on the fMRI Response to a Cognitive Task in Healthy Young People
Francis, S. T., Head, K., Morris, P. G., & Macdonald, I. A. (2006) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-200606001-00018 · Cited by 315
Relationship between respiration, end-tidal CO2, and BOLD signals in resting-state fMRI
Chang, C., & Glover, G. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.048 · Cited by 292
Birn, R. M., Murphy, K., & Bandettini, P. A. (2008) · Human Brain Mapping · doi:10.1002/hbm.20577 · Cited by 283
“…for example, that breath-holding results in an increase in the MRI signal [Abbott et al., 2005; Kastrup et al., 1998; Kwong et al., 1995; Li et al., 1999; Stillman et al., 1995; Thomason et al., 2005], that increases in the depth or rate of breathing cause a decrease in the fMRI signal…”
BackgroundBreath holding reveals differences in fMRI BOLD signal in children and adults
Thomason, M. E., Burrows, B. E., Gabrieli, J. D. E., & Glover, G. H. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.12.026 · Cited by 174
fMRI in the presence of task-correlated breathing variations
Birn, R. M., Murphy, K., Handwerker, D. A., & Bandettini, P. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.030 · Cited by 152
Selective reduction of blood flow to white matter during hypercapnia corresponds with leukoaraiosis
Mandell, D. M., Han, J. S., Poublanc, J., Crawley, A. P., Kassner, A., Fisher, J. A., & Mikulis, D. J. (2008) · Stroke · doi:10.1161/strokeaha.107.501692 · Cited by 114
Cholinergic Enhancement Reduces Spatial Spread of Visual Responses in Human Early Visual Cortex
Silver, M. A., Shenhav, A., & D'Esposito, M. (2008) · Neuron · doi:10.1016/j.neuron.2008.09.038 · Cited by 100
“, 1995) by causing hypercapnia that results in vascular dilation and increased blood flow (Li et al., 1999).”
Background
Metadata
- Authors
- Li, T.-Q., Kastrup, A., Takahashi, A. M., & Moseley, M. E.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 1999-02
- Volume
- 9
- Issue
- 2
- Pages
- 243-249
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2033465540
- Cited by
- 93
- References
- 3
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.