Fluorescence Correlation Spectroscopy
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
An experimental application of total internal reflection with fluorescence correlation spectroscopy (TIR/FCS) is presented. TIR/FCS is a new technique for measuring the binding and unbinding rates and surface diffusion coefficient of fluorescent-labeled solute molecules in equilibrium at a surface. A laser beam totally internally reflects at the solid-liquid interface, selectively exciting surface-adsorbed molecules. Fluorescence collected by a microscope from a small, well-defined surface area -5 ,gm2 spontaneously fluctuates as solute molecules randomly bind to, unbind from, and/or diffuse along the surface in chemical equilibrium. The fluorescence is detected by a photomultiplier and autocorrelated on-line by a minicomputer. The shape of the autocorrelation function depends on the bulk and surface diffusion coefficients, the binding rate constants, and the shape of the illuminated and observed region. The normalized amplitude of the autocorrelation function depends on the average number of molecules bound within the observed area. TIR/FCS requires no spectroscopic or thermodynamic change between dissociated and complexed states and no extrinsic perturbation from equilibrium. Using TIR/FCS, we determine that rhodamine-labeled immunoglobulin and insulin each nonspecifically adsorb to serum albumin-coated fused silica with both reversible and irreversible components. The characteristic time of the most rapidly reversible component measured is -5 ms and is limited by the rate of bulk diffusion. Rhodamine-labeled bivalent antibodies to dinitrophenyl (DNP) bind to DNP-coated fused silica virtually irreversibly. Univalent Fab fragments of these same antibodies appear to specifically bind to DNP-coated fused silica, accompanied by a large amount of nonspecific binding. TIR/FCS is shown to be a feasible technique for measuring absorption/desorption kinetic rates at equilibrium. In suitable systems where nonspecific binding is low, TIR/FCS should prove useful for measuring specific solute-surface kinetic rates. INTRODUCTION Association/dissociation reactions between biological molecules in solution and sites on a surface are involved in many important processes. When blood encounters a foreign surface, serum proteins adsorb, affecting subsequent interactions of biological molecules (Vroman and Adams, 1971; Brash and Lyman, 1971; Macritchie, 1978) and cells (Horbett and Weathersby, 1981; Grinnell and Feld, 1982; Neumann et al., 1979; Lahav et al., 1982) with the surface. For medical applications, substrate-immobilized antigens can be used to detect specific antibodies in a patient's serum (Giaver, 1978; Weetal, 1972). In industry, the manufacture and purification of biochemical products for medicine and biological research can use immobilized enzymes acting on substrates in solution (Mosbach, 1976; Lartigue and Yaverbaum, 1976). In cellular biology, hormones and neurotransmitters stimulate response by binding to specific receptors embedded in the plasma membrane of their target cells (Cuatrecasas, 1975; Whittaker, N. Thompson's present address is the Department of Chemistry, Stanford University, Stanford, CA 94305. 1975; Kahn, 1976). Similarly, an immune response is triggered after viruses or antigens attach to immunological cells (Eisen, 1974; Clark, 1980). Aside from its prominence in biology, medicine, and industry, the association/dissociation process itself holds theoretical interest. Nonspecific adsorption of solute molecules followed by surface diffusion can, under certain conditions, enhance reaction rates with specific sites on a surface (Adam and Delbriick, 1968; Berg and Purcell, 1977). Data gathered on model biochemical systems (Roberts and Hess, 1977; Wong et al., 1978) indirectly suggest that such rate enhancement indeed occurs in living systems. We describe the application of a technique for directly measuring rate parameters critical to the association/ dissociation process at a planar target, called total internal reflection with fluorescence correlation spectroscopy (TIR/FCS; Thompson, 1982 a). The theoretical and conceptual basis of TIR/FCS has previously been described (Thompson et al., 1981; Thompson, 1982 b). In TIR/FCS, fluorescent-labeled molecules are in chemical and thermodynamic equilibrium between a solution and a surface to 103 BIOPHYS. J. © Biophysical Society * 0007-3495/83/07/103/12 $1.00 Volume43 July 1983 103-114 which they reversibly adsorb. A laser beam totally internally reflects at the surface-solution interface, forming an electromagnetic field called the wave in a very thin layer of solution immediately adjacent to the surface. Those fluorescent solute molecules that are adsorbed to the surface are selectively excited by the evanescent wave. A microscope collects the fluorescence arising from a small surface area, defined by an image plane aperture, and a photomultiplier measures the fluorescence intensity in time. As individual molecules bind and unbind within the observatio
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Handbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Berg, H. C., & Purcell, E. M. (1977) · Biophysical Journal · doi:10.1016/s0006-3495(77)85544-6 · Cited by 1,758
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Internal Reflection Spectroscopy
Harrick, N. J., & Hoffman, J. G. (1968) · Physics Today · doi:10.1063/1.3034675 · Cited by 1,723
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Cell-substrate contacts illuminated by total internal reflection fluorescence.
Axelrod, D. (1981) · The Journal of cell biology · doi:10.1083/jcb.89.1.141 · Cited by 832
Macritchie, F. (1978) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60577-x · Cited by 686
Dynamics of fluorescence marker concentration as a probe of mobility
Koppel, D. E., Axelrod, D., Schlessinger, J., Elson, E. L., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85776-1 · Cited by 481
Statistical accuracy in fluorescence correlation spectroscopy
Koppel, D. E. (1974) · Physical Review A · doi:10.1103/physreva.10.1938 · Cited by 450
Applications of fluorescence in the biomedical sciences
Taylor, D. L., Waggoner, A. S., Lanni, F., Murphy, R. F., & Birge, R. (1986) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 371
Rotational brownian motion and fluorescence intensify fluctuations
Ehrenberg, M., & Rigler, R. (1974) · Chemical Physics · doi:10.1016/0301-0104(74)85005-6 · Cited by 366
Eisen, H. N., Simms, E. S., & Potter, M. (1968) · Biochemistry · doi:10.1021/bi00851a048 · Cited by 332
Fluorescence correlation spectroscopy as a probe of molecular dynamics
Aragón, S. R., & Pecora, R. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432357 · Cited by 329
Thompson, N. L., Burghardt, T. P., & Axelrod, D. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84905-3 · Cited by 316
Self-citationFluorescence correlation spectroscopy. III. Uniform translation and laminar flow
Magde, D., Webb, W. W., & Elson, E. L. (1978) · Biopolymers · doi:10.1002/bip.1978.360170208 · Cited by 298
Distribution of molecular aggregation by analysis of fluctuation moments.
Qian, H., & Elson, E. L. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.14.5479 · Cited by 179
Scanning fluorescence correlation spectroscopy. I. Theory and simulation of aggregation measurements
Petersen, N. O. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83709-2 · Cited by 175
On the analysis of high order moments of fluorescence fluctuations
Qian, H., & Elson, E. L. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82539-x · Cited by 166
Palmer, A. G., & Thompson, N. L. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83213-7 · Cited by 159
Self-citationFluorescence correlation spectroscopy and Brownian rotational diffusion
Aragón, S. R., & Pecora, R. (1975) · Biopolymers · doi:10.1002/bip.1975.360140110 · Cited by 158
Mechanism of the membrane potential sensitivity of the fluorescent membrane probe merocyanine 540
Dragsten, P. R., & Webb, W. W. (1978) · Biochemistry · doi:10.1021/bi00617a024 · Cited by 157
Optical methods in cell physiology
Ronot, X., & Adolphe, M. (1987) · Biochimie · doi:10.1016/0300-9084(87)90035-6 · Cited by 154
Fluorescence correlation spectroscopy applied to rotational diffusion of macromolecules
Ehrenberg, M., & Rigler, R. W. (1976) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000216x · Cited by 120
Fluorescence Correlation Spectroscopy and Photobleaching Recovery
Elson, E. L. (1985) · Annual Review of Physical Chemistry · doi:10.1146/annurev.pc.36.100185.002115 · Cited by 101
Membrane damage caused by irradiation of fluorescent concanavalin A.
Sheetz, M. P., & Koppel, D. E. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.7.3314 · Cited by 83
Theory of sample translation in fluorescence correlation spectroscopy
Palmer, A. G. I., & Thompson, N. L. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83340-4 · Cited by 80
Self-citationHigh-order fluorescence fluctuation analysis of model protein clusters.
Palmer, A. G. I., & Thompson, N. L. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.16.6148 · Cited by 80
Self-citationSeparation of the rotational contribution in fluorescence correlation experiments
Kask, P., Piksarv, P., Pooga, M., Mets, Ü., & Lippmaa, E. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82796-1 · Cited by 69
Kask, P., Piksarv, P., Mets, �., Pooga, M., & Lippmaa, E. (1987) · European Biophysics Journal · doi:10.1007/bf00256359 · Cited by 62
Kask, P., Piksarv, P., & Mets, �. (1985) · European Biophysics Journal · doi:10.1007/bf00254074 · Cited by 60
Mutual diffusion of interacting membrane proteins
Abney, J. R., Scalettar, B. A., & Owicki, J. C. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82678-5 · Cited by 19
Simple schemes for measuring autocorrelation functions
Kam, Z., Shore, H. B., & Fehér, G. (1975) · Review of Scientific Instruments · doi:10.1063/1.1134183 · Cited by 16
Cited by
Petosa, A. R., Jaisi, D. P., Quevedo, I. R., Elimelech, M., & Tufenkji, N. (2010) · Environmental Science & Technology · doi:10.1021/es100598h · Cited by 1,172
Two-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Anomalous Diffusion of Proteins Due to Molecular Crowding
Banks, D. S., & Fradin, C. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.051078 · Cited by 790
Fluorescence Correlation Spectroscopy
(2011) · SpringerReference · doi:10.1007/springerreference_33960 · Cited by 714
Fluorescence cross-correlation spectroscopy in living cells
Bacia, K., Kim, S. A., & Schwille, P. (2006) · Nature Methods · doi:10.1038/nmeth822 · Cited by 617
Metadata
- Authors
- Thompson, N. L.
- Venue
- Topics in Fluorescence Spectroscopy
- Publisher
- Kluwer Academic Publishers
- Published
- 2006-02-03
- Pages
- 337-378
- OpenAlex
- W171722806
- Cited by
- 262
- References
- 34
- FWCI
- 18.78
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.