A Comparison of Certain Gamma Band (40-HZ) Brain Rhythms in Cat and Man
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
I still recall my astonishment when I learned that if you open your eyes the electroencephalogram (EEG) alpha waves will disappear, and that if then you close them the alpha waves will reappear. The year was 1934, and I have been hoping ever since to learn what causes the 10-Hz rhythm in the first place, and then what brain process turns it off and on. The editors of this book have asked me to compare another human brain rhythm—in the region of 40 Hz this time—with a cat rhythm in the same frequency range that is discussed elsewhere in this volume by Gray and Singer and their colleagues, and by Eckhorn and his colleagues. I do as much as I can to oblige them in what follows, first describing some properties of the human 40-Hz phenomena, then comparing these with the microelectrode data from the cat. After concluding that the two differ in several ways, I branch out to consider the general problem of brain rhythms briefly, and to speculate on their possible physiological origins and functions. These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eckhorn, R., Bauer, R., Jordan, W., Brosch, M., Kruse, W., Munk, M., & Reitboeck, H. J. (1988) · Biological Cybernetics · doi:10.1007/bf00202899 · Cited by 2,330
A 40-Hz auditory potential recorded from the human scalp.
Galambos, R., Makeig, S., & Talmachoff, P. J. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.4.2643 · Cited by 1,247
Self-citationEngel, A. K., König, P., Gray, C. M., & Singer, W. (1990) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1990.tb00449.x · Cited by 437
Regan, D. (1989) · Medical Entomology and Zoology · Cited by 366
Kupersmith, M. J. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90137-2 · Cited by 254
Human Auditory Steady State Potentials
Stapells, D. R., Linden, D., Suffield, J. B., Hamel, G., & Picton, T. W. (1984) · Ear and Hearing · doi:10.1097/00003446-198403000-00009 · Cited by 246
Dynamics of Sensory and Cognitive Processing by the Brain
(1988) · Springer Series in Brain Dynamics · doi:10.1007/978-3-642-71531-0 · Cited by 239
Shaw, J. (1982) · Biological Psychology · doi:10.1016/0301-0511(82)90021-7 · Cited by 218
The gamma wave: a cortical information carrier?
Bressler, S. L. (1990) · Trends in Neurosciences · doi:10.1016/0166-2236(90)90039-d · Cited by 200 · cited 2×
“To recognize this fact, and in agreement with a solution Bressler recently advocated (Bressler, 1990), I replace "40 Hz" with "gamma band" throughout what follows, and define in the appended Glossary the related terminolgy to be used. The pioneers in EEG research invented the term gamma for spontaneous EEG frequencies…”
MethodHuman Auditory Steady State Evoked Potentials during Sleep
Linden, R. D., Campbell, K. B., Hamel, G., & Picton, T. W. (1985) · Ear and Hearing · doi:10.1097/00003446-198505000-00008 · Cited by 130
Reliability estimates for steady-state evoked potentials
Picton, T. W., Vajsar, J., Rodriguez, R. A., & Campbell, K. B. (1987) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(87)90039-6 · Cited by 129
Auditory steady-state responses: threshold prediction using phase coherence
Stapells, D. R., Makeig, S., & Galambos, R. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90024-1 · Cited by 123
Self-citationA Compound P300-40Hz Response of the Cat Hippocampus
Başar-Eroglu, C., & Başar, E. (1991) · International Journal of Neuroscience · doi:10.3109/00207459109167035 · Cited by 118
A high frequency mechanism which underlies visual evoked potentials
Regan, D. (1968) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(68)90020-5 · Cited by 116
Brain dynamics : progress and perspectives
Başar, E., & Bullock, T. H. (1989) · Springer eBooks · Cited by 109
The EEG is a Quasi-Deterministic Signal Anticipating Sensory-Cognitive Tasks
Başar, E., Başar-Eroglu, C., Roschke, J., & Schütt, A. (1989) · Springer series in brain dynamics · doi:10.1007/978-3-642-74557-7_5 · Cited by 97 · cited 3×
“The evidence for this improbable phenomenon was recently presented for man by Ba~ar et al. (1989), for cat from hippocampal recordings by Eroglu-Ba~ar and Ba~ar (1991) (see Fig.”
BackgroundInfluentialTHORNTON, C., CATLEY, D. M., JORDAN, C. C., Lehane, J. R., Royston, D., & Jones, J. G. (1983) · British Journal of Anaesthesia · doi:10.1093/bja/55.6.479 · Cited by 95
Visual evoked potential in man: Early oscillatory potentials
Cracco, R. Q., & Cracco, J. B. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90141-4 · Cited by 73
Event-related potentials in the retina and optic tectum of fish
Bullock, T. H., Hofmann, M. H., Nahm, F. K., New, J. G., & Prechtl, J. C. (1990) · Journal of Neurophysiology · doi:10.1152/jn.1990.64.3.903 · Cited by 62
Bartel, P., Blom, M., Robinson, E., van der Meyden, C., Sommers, D. K., & Becker, P. (1990) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(90)90054-h · Cited by 33
The CERP: Event-Related Perturbations in Steady-State Responses
Makeig, S., & Galambos, R. (1989) · Springer series in brain dynamics · doi:10.1007/978-3-642-74557-7_30 · Cited by 28
Self-citationAuditory and visual event-related perturbations in the 40 Hz auditory steady-state response
Rohrbaugh, J., Varner, J. L., Paige, S. R., Eckardt, M. J., & Ellingson, R. J. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90213-4 · Cited by 21 · cited 1×
“This DFT is a complex number that changes in characteristic ways when perturbations are introduced into the stimulus train producing the SSR; the resulting complex event-related potential (CERP) is currently under study as a possible method for measuring brain events correlated with cognitive behaviors (Makeig and Gal…”
Method
Cited by
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D. (2003) · International Journal of Audiology · doi:10.3109/14992020309101316 · Cited by 846
Mechanisms of human attention: event-related potentials and oscillations
Herrmann, C. S., & Knight, R. T. (2001) · Neuroscience & Biobehavioral Reviews · doi:10.1016/s0149-7634(01)00027-6 · Cited by 600
Human EEG gamma oscillations in neuropsychiatric disorders
Herrmann, C. S., & Demiralp, T. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.07.007 · Cited by 599
Başar-Eroglu, C., Başar, E., Demiralp, T., & Schürmann, M. (1992) · International Journal of Psychophysiology · doi:10.1016/0167-8760(92)90055-g · Cited by 542
Cognitive Control Deficits in Schizophrenia: Mechanisms and Meaning
Lesh, T. A., Niendam, T. A., Minzenberg, M. J., & Carter, C. S. (2011) · Neuropsychopharmacology · doi:10.1038/npp.2010.156 · Cited by 506
Metadata
- Authors
- Galambos, R.
- Venue
- Induced Rhythms in the Brain
- Publisher
- Birkhäuser Boston
- Published
- 1992
- Pages
- 201-216
- OpenAlex
- W61361051
- Cited by
- 165
- References
- 22
- FWCI
- 6.21
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.