AlignTransformer: Hierarchical Alignment of Visual Regions and Disease Tags for Medical Report Generation
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Recently, medical report generation, which aims to automatically generate a long and coherent descriptive paragraph of a given medical image, has received growing research interests. Different from the general image captioning tasks, medical report generation is more challenging for data-driven neural models. This is mainly due to 1) the serious data bias: the normal visual regions dominate the dataset over the abnormal visual regions, and 2) the very long sequence. To alleviate above two problems, we propose an AlignTransformer framework, which includes the Align Hierarchical Attention (AHA) and the Multi-Grained Transformer (MGT) modules: 1) AHA module first predicts the disease tags from the input image and then learns the multi-grained visual features by hierarchically aligning the visual regions and disease tags. The acquired disease-grounded visual features can better represent the abnormal regions of the input image, which could alleviate data bias problem; 2) MGT module effectively uses the multi-grained features and Transformer framework to generate the long medical report. The experiments on the public IU-Xray and MIMIC-CXR datasets show that the AlignTransformer can achieve results competitive with state-of-the-art methods on the two datasets. Moreover, the human evaluation conducted by professional radiologists further proves the effectiveness of our approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
BLEU: a method for automatic evaluation of machine translation
Papineni, K., Roukos, S., Ward, T., & Zhu, W.-J. (2001) · Proceedings of the 40th Annual Meeting on Association for Computational Linguistics - ACL '02 · doi:10.3115/1073083.1073135 · Cited by 21,344
Show, Attend and Tell: Neural Image Caption Generation with Visual Attention
Xu, K., Ba, J., Kiros, R., Cho, K., Courville, A., Salakhutdinov, R., Zemel, R., & Bengio, Y. (2015) · arXiv · doi:10.48550/arxiv.1502.03044 · Cited by 8,248 · cited 3×
“Most existing medical report generation models follow the standard image captioning approaches [41,40,43,1,27,26,25,32,8] and employ the encoder-decoder framework, e.”
BackgroundMethodShow and tell: A neural image caption generator
Vinyals, O., Toshev, A., Bengio, S., & Erhan, D. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298935 · Cited by 6,318 · cited 2×
“Most existing medical report generation models follow the standard image captioning approaches [41,40,43,1,27,26,25,32,8] and employ the encoder-decoder framework, e.”
BackgroundOn the difficulty of training recurrent neural networks
Pascanu, R., Mikolov, T., & Bengio, Y. (2012) · arXiv · doi:10.48550/arxiv.1211.5063 · Cited by 4,310
MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reports
Johnson, A. E. W., Pollard, T. J., Berkowitz, S. J., Greenbaum, N. R., Lungren, M. P., Deng, C.-Y., Mark, R. G., & Horng, S. (2019) · Scientific Data · doi:10.1038/s41597-019-0322-0 · Cited by 1,816
Microsoft COCO Captions: Data Collection and Evaluation Server
Chen, X., Fang, H., Lin, T.-Y., Vedantam, R., Gupta, S., Dollar, P., & Zitnick, C. L. (2015) · arXiv · doi:10.48550/arxiv.1504.00325 · Cited by 1,614 · cited 2×
“To test the performance, we adopt the widely-used BLEU [33], METEOR [3] and ROUGE-L [23], which are reported by the evaluation toolkit [6].”
BackgroundMethodMeshed-Memory Transformer for Image Captioning
Cornia, M., Stefanini, M., Baraldi, L., & Cucchiara, R. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr42600.2020.01059 · Cited by 1,259
Preparing a collection of radiology examinations for distribution and retrieval
Demner-Fushman, D., Kohli, M. D., Rosenman, M. B., Shooshan, S. E., Rodriguez, L., Antani, S., Thoma, G. R., & McDonald, C. J. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv080 · Cited by 1,164
X-Linear Attention Networks for Image Captioning
Pan, Y., Yao, T., Li, Y., & Mei, T. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr42600.2020.01098 · Cited by 720
Generating Radiology Reports via Memory-driven Transformer
Chen, Z., Song, Y., Chang, T.-H., & Wan, X. (2020) · Proceedings of the 2020 Conference on Empirical Methods in Natural Language Processing (EMNLP) · doi:10.18653/v1/2020.emnlp-main.112 · Cited by 693
On the Automatic Generation of Medical Imaging Reports
Jing, B., Xie, P., & Xing, E. (2018) · Proceedings of the 56th Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers) · doi:10.18653/v1/p18-1240 · Cited by 657 · cited 5×
“However, due to the data bias and the very long sequence, some errors occur in the generated reports of the existing methods, like duplicate reports, inexact descriptions, etc [42,44,17].”
BackgroundInfluentialMIMIC-CXR-JPG, a large publicly available database of labeled chest radiographs
Johnson, A. E. W., Pollard, T. J., Greenbaum, N. R., Lungren, M. P., Deng, C.-Y., Peng, Y., Lu, Z., Mark, R. G., Berkowitz, S. J., & Horng, S. (2019) · arXiv · doi:10.48550/arxiv.1901.07042 · Cited by 269
Cited by
Advances in medical image analysis with vision Transformers: A comprehensive review
Azad, R., Kazerouni, A., Heidari, M., Aghdam, E. K., Molaei, A., Jia, Y., Jose, A., Roy, R., & Merhof, D. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103000 · Cited by 485
Radiology report generation with a learned knowledge base and multi-modal alignment
Yang, S., Wu, X., Ge, S., Zheng, Z., Zhou, S. K., & Xiao, L. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102798 · Cited by 199
Self-citationMETransformer: Radiology Report Generation by Transformer with Multiple Learnable Expert Tokens
Wang, Z., Liu, L., Wang, L., & Zhou, L. (2023) · 2023 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52729.2023.01112 · Cited by 184
“Another group of works [34, 44] utilizes disease tags to facilitate report generation.”
BackgroundA medical multimodal large language model for future pandemics
Liu, F., Zhu, T., Wu, X., Yang, B., You, C., Wang, C., Lu, L., Liu, Z., Zheng, Y., Sun, X., et al. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00952-2 · Cited by 155
Self-citationA scoping review on multimodal deep learning in biomedical images and texts
Sun, Z., Lin, M., Zhu, Q., Xie, Q., Wang, F., Lu, Z., & Peng, Y. (2023) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2023.104482 · Cited by 69
“Another notable contribution is the AlignTransformer proposed by You et al. [123], which e ff ectively addresses data bias and is particularly well-suited for long-sequence report generation.”
Background
Metadata
- Authors
- You, D., Liu, F., Ge, S., Xie, X., Zhang, J., & Wu, X.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2021
- Pages
- 72-82
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W4285531589
- Cited by
- 141
- References
- 15
- FWCI
- 6.32
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.