Concentric Tube Robots: The State of the Art and Future Directions
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Needle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704 · cited 1×
“The term “steerable needle” typically refers to devices that harness tip-tissue interaction forces to steer [82, 57, 2].”
Nonholonomic Modeling of Needle Steering
Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065388 · Cited by 633 · cited 1×
“The term “steerable needle” typically refers to devices that harness tip-tissue interaction forces to steer [82, 57, 2].”
Continuum robots - a state of the art
Robinson, G., & Davies, J. B. C. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.774029 · Cited by 619
State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery
Puangmali, P., Althoefer, K., Seneviratne, L. D., Murphy, D., & Dasgupta, P. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917481 · Cited by 588 · cited 2×
“investigated in the context of minimally invasive surgical tools [56], but the only one that has been specifically designed for and applied to a concentric tube robot is a tip force sensor which measures force magnitude and contact angle based on electrical resistance of fluid-filled channels [5, 32].”
Nonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots
Rucker, D. C., Jones, B. A., & Webster, R. J., III (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2062570 · Cited by 513 · cited 6×
“Experimental testing of the model has shown that with calibration, mean error in the prediction of tip position can be as low as 1% to 3% of overall arc length [62, 68, 28, 44].”
InfluentialSelf-citationMechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485 · cited 2×
“Many potential cannula design choices will have bifurcations where solutions appear and disappear [85, 68, 28].”
A Telerobotic System for Transnasal Surgery
Burgner, J., Rucker, D. C., Gilbert, H. B., Swaney, P. J., Russell, P. T., Weaver, K. D., & Webster, R. J. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2265804 · Cited by 294 · cited 6×
“robot and also developed a curette end effector for endonasal surgery [12].”
InfluentialSelf-citation
Cited by
Continuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Self-citationHe, Q., Wang, Z., Wang, Y., Minori, A., Tolley, M. T., & Cai, S. (2019) · Science Advances · doi:10.1126/sciadv.aax5746 · Cited by 564
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Russo, M., Sadati, S. M. H., Dong, X., Mohammad, A., Walker, I. D., Bergeles, C., Xu, K., & Axinte, D. A. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200367 · Cited by 263
Riek, L. D. (2017) · Communications of the ACM · doi:10.1145/3127874 · Cited by 257
Frontiers of Medical Robotics: From Concept to Systems to Clinical Translation
Troccaz, J., Dagnino, G., & Yang, G.-Z. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052502 · Cited by 194
Steerable catheters for minimally invasive surgery: a review and future directions
Hu, X., Chen, A., Luo, Y., Zhang, C., & Zhang, E. (2018) · Computer Assisted Surgery · doi:10.1080/24699322.2018.1526972 · Cited by 184
“A review of the state of arts of the device of the concentric tube robot can be found in [86].”
Background
Metadata
- Authors
- Gilbert, H. B., Rucker, D. C., & Webster III, R. J.
- Venue
- Springer Tracts in Advanced Robotics
- Publisher
- Springer International Publishing
- Published
- 2016
- Pages
- 253-269
- ISSN
- 1610-742X (ISSN-L)
- 1610-7438
- OpenAlex
- W2462654948
- Cited by
- 197
- References
- 31
- FWCI
- 34.25
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.