The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Wearable Assistive Devices for the Blind
Open accessAbstract
Assistive devices are a key aspect in wearable systems for biomedical applications, as they represent potential aids for people with physical and sensory disabilities that might lead to improvements in the quality of life. This chapter focuses on wearable assistive devices for the blind. It intends to review the most significant work done in this area, to present the latest approaches for assisting this population and to understand universal design concepts for the development of wearable assistive devices and systems for the blind.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An experimental system for auditory image representations
Meijer, P. B. L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.121642 · Cited by 900
Beyond sensory substitution—learning the sixth sense
Nagel, S. K., Carl, C., Kringe, T., Märtin, R., & König, P. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r02 · Cited by 225
Design of a wearable tactile display
Gemperle, F., Ota, N., & Siewiorek, D. (2002) · Proceedings Fifth International Symposium on Wearable Computers · doi:10.1109/iswc.2001.962082 · Cited by 142
Cited by
Benko, H., Holz, C., Sinclair, M., & Ofek, E. (2016) · Proceedings of the 29th Annual Symposium on User Interface Software and Technology · doi:10.1145/2984511.2984526 · Cited by 298
Bhowmick, A., & Hazarika, S. M. (2017) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-016-0235-6 · Cited by 271
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
Safe Local Navigation for Visually Impaired Users With a Time-of-Flight and Haptic Feedback Device
Katzschmann, R. K., Araki, B., & Rus, D. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2800665 · Cited by 214
“d) Vibration specifications: Each vibration unit contains an LRA that vibrates at ∼175 Hz, which falls within the ∼40–400 Hz range in which human skin can feel vibration, and lies close to the 200–300 Hz range of peak sensitivity [11].”
BackgroundInfluentialWang, H.-C., Katzschmann, R. K., Teng, S., Araki, B., Giarre, L., & Rus, D. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989772 · Cited by 167
Metadata
- Authors
- Velázquez, R.
- Venue
- Lecture Notes in Electrical Engineering
- Publisher
- Springer Berlin Heidelberg
- Published
- 2010
- Pages
- 331-349
- ISSN
- 1876-1100 (ISSN-L)
- 1876-1119
- OpenAlex
- W1781239457
- Cited by
- 238
- References
- 3
- FWCI
- 42.88
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Assistive Devices for the Blind. https://app.cochat.ai/papers/10.1007/978-3-642-15687-8_17
- The paper
- Velázquez, R. (2010). Wearable Assistive Devices for the Blind. Lecture Notes in Electrical Engineering. https://doi.org/10.1007/978-3-642-15687-8_17
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.